Plan Review Details - Permit 00010858
Plan Review Stops For Permit 00010858
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-04-13 Cont ID  
Sent By rmcdouga Date 2000-04-13 Time 15:44 Rev Time 0.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-01-08 00:00:00OK PER DEWEY PALMER 2/10/00

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-02-05 Cont ID  
Sent By jleech Date 2000-02-05 Time 09:07 Rev Time 0.50
Received By jleech Date 2000-02-05 Time 09:07 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2000-03-17 Cont ID  
Sent By tlarge Date 2000-03-17 Time 17:47 Rev Time 0.33
Received By tlarge Date 2000-03-17 Time 17:47 Sent To  
Notes
2001-01-08 00:00:00PROVISO:SUBMIT NEW SANITARY RISER PRIOR
 TO ROUGH PLBG.INSP

Review Stop P PLUMBING
Rev No 1 Status F Date 2000-01-27 Cont ID  
Sent By tlarge Date 2000-01-27 Time 06:09 Rev Time 0.33
Received By tlarge Date 2000-01-27 Time 06:07 Sent To  
Notes
2001-01-08 00:00:00LOCATION OF FIXTURES ON SANITARY RISER
 DOESN'T CORRELATE W/ARCH.FLOOR PLAN.
 COUNTYWIDE AMENDMENTS TO SPC SEC.104.2.1

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2000-04-13 Cont ID  
Sent By rmcdouga Date 2000-04-13 Time 15:13 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-03-07 Cont ID  
Sent By jcaloger Date 2000-03-07 Time 12:06 Rev Time 1.50
Received By jcaloger Date   Time   Sent To  
Notes
2001-01-08 00:00:00PLANS ARE NOT DESIGNED TO THE 1997 SBC.
 NOTES ON PLAN S SPECIFY 1994EDITION.
  
 FILL OUT THE HEADING ON THE DESIGN COMPL
 IANCE FORM. NEEDS ADDRRESS
  
 PLANS INCLUDE MULTIPLE OPTIONS AND
 ELEVATIONS.SUBMIT PLANS FOR ONLY THE
 THE OPTIONS TO BE USED.
  
  
 THE TYPICAL WALL SECTION REFERS TO THE
 INVALID SSTD 10-93.CANNOT MIX DESIGN
 CRITERIAS,SSTD AND SBC.
  
  
 FRONT ENTRY DOORS WHICH ARE SERVING AS
 THE EGRESS FOR THE HOUSE ARE REQUIRED TO
 PROVIDE 32" CLEAR OPENING WHEN ONE DOOR
 LEAF IS OPENED.
  
  
 PLANS ARE REQIRED TO BE SPECIFIC.
 PROVIDE THE ADDRESS ON THE PLANS.
  
  
  
 ROOF TILE PRODUCT APPROVAL, THE PALM
 BEACH COUNTY CHECK LIST IS INVALID SINCE
 THE PROPOSED TILES HAVE METRO DADE
 APPROVAL.
  
  
 ROOF TILE, SPECIFY THE METHOD OF ATTACH-
 MENT.IF NAIL ON SYSTEM PROVIDE THE
 ATTACHMENT CALCULATIONS,SEE PAGE 10
 OF THE PRODUCT APPROVAL.
  
  
  
 PROVIDE PRODUCT APPROVAL FOR THE
 OVERHEAD GARAGE DOOR.
  
  
 NORANDEX PRODUCT APPROVAL IS REQUIRED TO
 HAVE THE DESIGNER OF RECORD RAISED SEAL.
  
  
 THE HEAT GAIN AND LOSS SPECIFYS THE 3650
 MODEL THIS IS THE 3576 MODEL, CLARIFY.
  
  
 ENERGY FORM 600A,COMPLETE HEADING AND
 NEEDS OWNER AGENT SIGNATURE.
  
  
 THE WIND PRESURES FOR THE OVERHEAD
 GARAGE DOOR DOES AS STATED IN SCHEDULE
 ARE +28 & -30.I CALCULATE THE PRES-
 URE AS FOLLOWS 28.3 (FROM 1606.2A) TIMES
 1.2 (1606.2C) = -33.96 AND 28.3 TIMES
 1.1= +31.13.CLARIFY
  
  
 STAIR THREAD AND RISER DO NOT MEET SECT.
 1007.3 (2RISER + 1 THREAD). ALSO THREAD
 NEEDS TO BE A MIN OF 9" EXCLUSIVE OF
 NOSING.
  
 PROVIDE DETAIL FOR CONSTRUCTING THE
 STAIR GUARDRAIL IN ACCORDANCE WITH SECT.
 1015.5 SBC 1997.
  
  
 THE PRODUCT APPROVAL FOR THE HURRICANE
 SHUTTERS NEEDS TO INCLUDE A PLAN LAYOUT
 WITH THE OPENINGS IDENTIFIED.
  
 NOT ALL ABOVE ITEMS COMPLETE 4/3/00.
 CHECK LIST WRITTEN AND ATTACHED TO PLANS
  
  
  
  
  
  
  
  
  
 .

Review Stop Z ZONING
Rev No 1 Status P Date 2000-01-25 Cont ID  
Sent By gjoyce Date 2000-01-25 Time 09:38 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***