Plan Review Details - Permit 00010763
Plan Review Stops For Permit 00010763 |
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2000-03-01 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2000-03-01 |
Time |
14:41 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2000-03-01 |
Time |
14:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2000-01-21 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2000-01-21 |
Time |
06:20 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | ************** PROVISO **************** | | | | 1)NOTE:AS PER OUR CONVERSATION PLEASE | | CHECK FAULT CURRENT CALCULATIONS FOR | | AIC RATING. FPL CAN GIVE FALUT CURRENT | | AVAILABILITY. | | | | 2)NOTE:PLEASE SHOW GROUNDING ELECTRODE | | CONDUCTOR GOING TO BLDG.STEEL ALSO AS S | | REQ`D BY 250-81 FO THE NEC. | | | | 3)NOTE: BATH(S) CIRCUT DOES NOT NEED TO | | BE INCLUDED IN LOAD CALCULATION BUT | | NEEDS TO BE ON PANEL SCHEDULE. | | | | 4)NOTE: RISER DIAGRAM SHOWS FEEDTO | | PANEL GOING OVERHEAD. IF THIS IS THE | | CASE THERE CANNOT BE OVER 8`OF CONDUCTOR | | INSIDE THE STRUCTURE AS PER ART;230-70A | | OF THE NEC. IF IT IS GOING TO BE IN- | | -STALLED IN SLAB THEN PLEASE SHOW. | | | | PLESE HAVE ALL THE ABOVE INFORMATION | | SUBMITTED FOR REVIEW AND APPROVAL BEFORE | | FIRST ROUGH ELECTRICAL INSPECTION IS | | CALLED IN. IF THERE ARE ANY QUESTIONS; | | CALL; 561-659-8096 EXT 8372 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2000-03-13 |
|
|
Cont ID |
|
Sent By |
cthirben |
Date |
2000-03-13 |
Time |
16:37 |
Rev Time |
0.50 |
Received By |
cthirben |
Date |
2000-03-13 |
Time |
16:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2000-01-24 |
|
|
Cont ID |
|
Sent By |
fknapp |
Date |
2000-01-24 |
Time |
16:03 |
Rev Time |
0.00 |
Received By |
fknapp |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | APPROVED PER BILL STAPLES |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2000-01-19 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2000-01-19 |
Time |
07:49 |
Rev Time |
0.50 |
Received By |
tlarge |
Date |
2000-01-19 |
Time |
07:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2000-01-24 |
|
|
Cont ID |
|
Sent By |
fknapp |
Date |
2000-01-24 |
Time |
14:19 |
Rev Time |
4.00 |
Received By |
fknapp |
Date |
2000-01-24 |
Time |
10:28 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | | | | | *****************PROVISO**************** | | | | SBC 104.2.2 | | | | 1)PROVIDE JOB/SITE LOCATION ON PRODUCT | | APPROVAL SUBMITTAL FORMS. | | | | 2)PROVIDE 2 CURRENT COPIES OF PRODUCT | | APPROVAL FOR FRONT DOOR ASSEMBLY WITH | | SIDELITE. | | | | 3)PROVIDE SAFETY GLASS AS NOTED ON PLAN. | | | | 4)PROVIDE NAILING FOR PLYWOOD SHEATHING | | AS NOTED ON PLAN PER CITY AMENDMENTS | | 2306.1 | | | | 5)PROVIDE INSTALLATION SCHEDULE AND KEY | | PLAN FOR STORM PANELS WITH SPECIFIC | | ANCHORS TO BE USED. | | | | PLEASE SUBMIT PRIOR TO INSTALLATION. | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | BEACH CO., THE PERMIT PLANS STAMPED BY | | THEM AND THE RECIEPT ATTACHED TO THE | | PERMIT APPLICATION. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2000-01-24 |
|
|
Cont ID |
|
Sent By |
fknapp |
Date |
2000-01-24 |
Time |
16:03 |
Rev Time |
0.00 |
Received By |
fknapp |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | APPROVED PER GRACE JOYCE |
|
|
|