| Plan Review Notes For Project Z23060022 |
| Project Number |
Z23060022 |
|
| Review Stop |
PU |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2023-07-13 12:05:39 | -DENOTE SIZE AND MATERIAL OF EXISTING UTILITIES | | | -UNUSED LATERALS/SERVICES WILL REQUIRE REMOVAL UP TO | | | MAIN | | | -HARD TO DIFFERENTIATE MAINS AND SERVICES | | | -SHOW ALL EXISTING AND PROPOSED VALVES AND | | | APPURTENANCES | | | -ENSURE 5 FOOT RADIAL CLEARANCE FOR BOTH METER BOX AND | | | CLEANOUT | | | -SHOW ALL EXISTING DRY UTILITIES | | | -CCTV REQUIRED IN ORDER TO CONFIRM LOCATIONS OF | | | EXISITNG LATERALS | | | -EXHIBIT ALL UTILITY CROSSINGS BETWEN PROPOSED AND | | | EXISTING UTILITIES | | | -DENOTE THE DOWNSTREAM LIFT STATION THAT SERVES THE | | | PROJECT AREA | | | -INCLUDE LEGEND AND DATUM CONVERSION | | | -PROVIDE DEMAND CALCULATIONS TO DETERMINE SUFFICIENT | | | FLOW SERVED BY EXISTING PIPES | | | |
| |