Plan Review Notes
Plan Review Notes For Project Z23050026
Project Number Z23050026
Review Stop TRAFFIC
Sequence Number 2
Notes
Date Text
2023-07-27 21:35:561) SATISFIED. SHOWCASE LOADING ZONE DIMENSIONS AND
 VERIFY THAT IT FULFILLS CODE REQUIREMENT. DIMENSIONS
 ARE NOT SHOWN IN C.03. PLEASE NOTE: THE FACT THAT THE
 PROJECT WAS PREVIOUSLY APPROVED, DOES NOT PRECLUDE A
 REVIEWER TO REQUEST CORRECTIONS OR CLARIFICATIONS FOR
 AN ITEM THAT MAY HAVE BEEN OVERLOOKED
 2) SATISFIED. GIVEN THE INCREASE IN VEHICULAR TRAFFIC,
 THE ALLEY MUST BE DESIGNATED ONE-WAY; SPECIFICALLY IN
 THE EASTBOUND DIRECTION, SO TO ALLOW RIGHT-TURN FULL
 CIRCULATION OF THE BLOCK. PROVIDE AN UPDATED SITE PLAN
 SHOWCASING THE FULL EXTENT OF THE ALLEY FROM PARKER TO
 LAKE AVE, AND THE CORRESPONDING SIGNAGE AND PAVEMENT
 MARKINGS, ACCORDINGLY
 3) SATISFIED. PROVIDE ALL DIMENSIONS FOR EACH PARKING
 STALL ALONG THE CURVED SECTION
 4) PARTIALLY SATISFIED. PROVIDE AUTOTURN ANALYSIS FOR
 GARBAGE TRUCK AND/OR SERVICE VEHICLES DRIVING IN AND
 OUT OF THE PROPOSED DEVELOPMENT AND/OR LOADING ZONE
 MANEUVERING, WITH VEHICLE DYNAMIC ENVELOPES AND WHEEL
 PATHS CLEARLY DISTINCT AND DEFINED IN DIFFERENT COLORS.
 PLEASE SHOWCASE A SERVICE/DELIVERY VEHICLE ENTERING THE
 FACILITY, MANEUVERING IN & OUT OF THE LOADING ZONE, AND
 THEN EXITING. PLEASE PROVIDE DETAILS OF THE
 CONTAINERS??? ROLLOUT OPERATION (I.E. ROUTE AND
 DROP-OFF LOCATION)
 5) TO BE SATISFIED PRIOR TO CO. PROVIDE PALM TRAN
 AGREEMENT/APPROVAL PERTAINING TO THE FUTURE BUS STOP
 LOCATION AND CONFIGURATION. PLEASE PROVIDE BUS STOP
 DRAFT/PROPOSED DESIGN. THIS COMMENT WAS A CONDITION OF
 APPROVAL FROM A PREVIOUS REVIEW (Z20030026). IT IS
 STRONGLY RECOMMENDED TO INITIATE CONVERSATION WITH PALM
 TRAN SO TO TIMELY IDENTIFY LOCATION AND DESIGN OF THE
 BUS SHELTER, AND AVOID DELAYING CO ISSUANCE
 6) NOT SATISFIED. PROVIDE A CONSTRUCTION MANAGEMENT
 PLAN. PLEASE REFER TO CITY CODE 86-246 FOR DETAILS.
 PLEASE PROVIDE A SPECIFIC DOCUMENT ACCORDING TO CODE
 REQUIREMENTS (I.E. CONSTRUCTION MANAGEMENT SITE PLAN,
 WRITTEN STATEMENT DETAILING OF HOW AND WHERE
 CONSTRUCTION WORKERS WILL PARK). IN THE DOCUMENT, IT IS
 RECOMMENDED TO IDENTIFY AND ILLUSTRATE
 ALTERNATIVE/OPTIONAL PARKING LOCATIONS IN CASE OF
 VEHICLE OVERFLOW AND/OR CONSTRAINTS DUING VARIOUS
 CONSTRUCTION PHASES
 7) NOT SATISFIED. PROVIDE COUNTY LETTER OR PROOF OF
 APPROVAL OF THE BELVEDERE DRIVEWAY. ACCESS MANAGEMENT
 STANDARDS REQUIRE A MINIMUM OF 30-FEET LONG THROAT
 DISTANCE, CURRENT PROPOSED IS 25-FEET. THIS COMMENT WAS
 A CONDITION OF APPROVAL FROM A PREVIOUS REVIEW
 (Z20030026). THE PROVIDED COUNTY ROW PERMIT IS NOT
 PERTINENT.
 8) SATISFIED. INSTALL RIGHT-TURN ONLY PAVEMENT MARKINGS
 AT THE BELVEDERE AND ALLEY DRIVEWAY EXIT LANES
  
 VALERIO ORICCHIO
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]
  
  Print


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved