| Date |
Text |
| 2023-06-08 12:02:56 | |
| | 1) SHOWCASE LOADING ZONE DIMENSIONS AND VERIFY THAT IT |
| | FULFILLS CODE REQUIREMENT |
| | 2) GIVEN THE INCREASE IN VEHICULAR TRAFFIC, THE ALLEY |
| | MUST BE DESIGNATED ONE-WAY; SPECIFICALLY IN THE |
| | EASTBOUND DIRECTION, SO TO ALLOW RIGHT-TURN FULL |
| | CIRCULATION OF THE BLOCK. PROVIDE AN UPDATED SITE PLAN |
| | SHOWCASING THE FULL EXTENT OF THE ALLEY FROM PARKER TO |
| | LAKE AVE, AND THE CORRESPONDING SIGNAGE AND PAVEMENT |
| | MARKINGS, ACCORDINGLY |
| | 3) PROVIDE ALL DIMENSIONS FOR EACH PARKING STALL ALONG |
| | THE CURVED SECTION |
| | 4) PROVIDE AUTOTURN ANALYSIS FOR GARBAGE TRUCK AND/OR |
| | SERVICE VEHICLES DRIVING IN AND OUT OF THE PROPOSED |
| | DEVELOPMENT AND/OR LOADING ZONE MANEUVERING, WITH |
| | VEHICLE DYNAMIC ENVELOPES AND WHEEL PATHS CLEARLY |
| | DISTINCT AND DEFINED IN DIFFERENT COLORS |
| | 5) PROVIDE PALM TRAN AGREEMENT/APPROVAL PERTAINING TO |
| | THE FUTURE BUS STOP LOCATION AND CONFIGURATION. PLEASE |
| | PROVIDE BUS STOP DRAFT/PROPOSED DESIGN |
| | 6) PROVIDE A CONSTRUCTION MANAGEMENT PLAN. PLEASE REFER |
| | TO CITY CODE 86-246 FOR DETAILS |
| | 7) PROVIDE COUNTY LETTER OR PROOF OF APPROVAL OF THE |
| | BELVEDERE DRIVEWAY. ACCESS MANAGEMENT STANDARDS REQUIRE |
| | A MINIMUM OF 30-FEET LONG THROAT DISTANCE, CURRENT |
| | PROPOSED ONE IS 25-FEET |
| | 8) INSTALL RIGHT-TURN ONLY PAVEMENT MARKINGS AT THE |
| | BELVEDERE AND ALLEY DRIVEWAY EXIT LANES |
| | |
| | VALERIO ORICCHIO |
| | CITY TRANSPORTATION ENGINEER |
| | 561-494-1092 |
| | [email protected] |
| | |
| |