| Date |
Text |
| 2023-06-22 03:57:35 | TRAFFIC COMMENTS |
| | 1) PROVIDE COUNTY TPS LETTER, ONCE RECEIVED |
| | 2) PROVIDE FDOT ACCESS LETTER |
| | |
| | SITE COMMENTS |
| | 3) INSTALL STOP BAR AND SIGN AT THE SPENCER DR DRIVEWAY |
| | 4) WHY IS THE NORTHERN ADA STALL PLACED AT THAT |
| | LOCATION? CONSIDER RELOCATING IT ON THE OPPOSITE SIDE |
| | NEAR A BUILDING ENTRANCE. OTHERWISE, PLEASE SET THE |
| | CROSSWALK PERPENDICULAR TO THE DRIVE AISLE |
| | 5) PROVIDE AUTOTURN ANALYSIS FOR GARBAGE TRUCK AND FUEL |
| | TANKER DRIVING IN AND OUT OF THE PROPOSED DEVELOPMENT |
| | WITH VEHICLE DYNAMIC ENVELOPES AND WHEEL PATHS CLEARLY |
| | DISTINCT AND DEFINED IN DIFFERENT COLORS. PLEASE |
| | PROVIDE DOCUMENT NAME AND/OR SHEET NUMBER |
| | 6) IDENTIFY AND DESIGNATE AN EASILY ACCESSIBLE |
| | MICRO-MOBILITY STATION AREA (MINIMUM 8 X 20 FEET) AND |
| | PROVIDE BASIC ELECTRIFICATION READINESS WITH THE |
| | FOLLOWING SPECS: A CONDUIT (2-INCH SCHEDULE 40 PVC) TO |
| | THE POWER SOURCE WITH AN ELECTRICAL PULL BOX (240V / |
| | 10,000W CIRCUIT). PLEASE INSERT THIS FEATURE IN THE |
| | T-1.0 OR T1.1 SITE PLAN |
| | 7) ARE THERE ANY BUS STOPS BEING IMPACTED? |
| | 8) PROVIDE A CONSTRUCTION MANAGEMENT PLAN. PLEASE REFER |
| | TO CITY CODE 86-246 FOR DETAILS |
| | 9) BOTH DRIVEWAYS ARE TOO WIDE. INSTALL A DIVIDER |
| | ISLAND, WHICH COULD BE EITHER MOUNTABLE OR PAINTED WITH |
| | CROSS-HATCHED PATTERNS, SO TO REDUCE THE WIDTH OF EACH |
| | DRIVEWAY LANE TO 12-FEET |
| | 10) AT THE SPENCER DR DRIVEWAY, ALSO INSTALL |
| | CROSS-HATCHED MARKINGS ON THE NORTHERN SIDE, SO TO |
| | VISUALLY PROVIDE A STRAIGHT DRIVEWAY THROAT |
| | 11)ASSUMING ONE-WAY DIRECTIONALITY AND THE DEPICTED |
| | 40-FEET LONG CROSS-HATCHED ELEMENT BEING A TRAFFIC |
| | DIVIDER, INSTALL DO-NOT-ENTER SIGNS AT THE EXIT OF THE |
| | ATM MACHINE DRIVE AREA |
| | VALERIO ORICCHIO |
| | |
| | CITY TRANSPORTATION ENGINEER |
| | 561-494-1092 |
| | [email protected] |
| | |
| |