2023-06-27 12:21:45THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE
 6/2/2023 SUBMITTAL.
  
 1. [SATISFIED] 45TH ST. IS MAINTAINED BY PALM BEACH
 COUNTY. ANY WORK PROPOSED IN THE R/W WILL NEED TO BE
 PERMITTED BY PBC.
  
 2. [NOT SATISFIED - PAVING MARKING AND SIGNAGE PLAN
 REFERS TO BCTED] REMOVE REFERENCES TO BROWARD COUNTY.
  
 3. [SATISFIED] IF SITE IS WITHIN A SPECIAL FLOOD HAZARD
 AREA THEN THE BUILDINGS AND MECHANICAL EQUIPMENT ARE TO
 BE LOCATED A MINIMUM OF TWO FEET ABOVE THE BASE FLOOD
 ELEVATIONS (2 FEET OF FREEBOARD). SITE DOES NOT APPEAR
 TO BE WITHIN A SFHA.
  
 4. [NOT SATISFIED - RESPONSE INDICATED LETTER WAS
 FORTHCOMING] PROVIDE LETTER FROM ADJACENT PROPERTY
 OWNER TO THE SOUTH (SCHOOL BOARD OF PALM BEACH COUNTY)
 OR OWNER OF ANY DRAINAGE EASEMENT APPROVING THE
 DRAINAGE CONNECTION AND DISCHARGE ONTO THEIR SITE OR
 EASEMENT. PROVIDE A COPY OF THE EASEMENT IF APPLICABLE.
  
 5. [SATISFIED] LABEL MH#9 ON SHEET C-1.
  
 6. [NOT SATISFIED - SECTIONS ON SHEET C-2 SHOW THE
 FOOTER CROSSING THE PROPERTY LINE.] WALL FOOTERS SHOULD
 BE CONSTRUCTED ENTIRELY WITHIN THE PROPERTY BOUNDARY.
  
 7. [PARTIALLY SATISFIED - CONTOURS REMOVED FROM PGD
 PLAN BUT SECTIONS ON SHEET C-2 SHOW DEPRESSED AREAS AND
 THE PGD PLAN SHOWS STORM PIPES EXTENDING INTO THE
 FORMALLY GRADED AREAS.] EXPLAIN OR SHOW HOW THE
 RETENTION AREAS WILL DRAIN. RE-LABEL AS DETENTION AREAS
 IF THERE WILL BE CONNECTIONS TO THE ONSITE DRAINAGE
 SYSTEM AND OUTFALL PIPE.
  
 8. [SATISFIED] CREATE A SWALE ALONG THE BACK OF
 SIDEWALK ALONG 45TH STREET TO PREVENT DIRECT RUNOFF
 ONTO THE SIDEWALK.
  
 9. [SATISFIED] LABEL THE LANDSCAPE BUFFER ON SECTION
 B-B.
  
 10. [SATISFIED] ADD TO SHEET C-2 THE VERTICAL DATUM
 CONVERSION EQUATION TO NGVD1929.
  
 11. [SATISFIED - PARKING STALLS DO NOT APPEAR TO BE
 REDUCED IN LENGTH] CONSIDER REDUCING THE AMOUNT OF
 IMPERVIOUS AREA BY REDUCING THE PARKING STALL DEPTHS
 AND PROVIDING TWO FEET OF LANDSCAPED OVERHANG. THE
 RAISED CURB CAN FUNCTION AS THE WHEEL STOPS.
  
 12.[NOT SATISFIED - THIS INFORMATION WILL BE NEEDED ON
 THE ENGINEERING PERMIT SET OF DRAWINGS] LABEL TOP AND
 BOTTOM ELEVATIONS OF THE EXFILTRATION TRENCH AND TRENCH
 WIDTH ON THE EXFILTRATION TRENCH DETAIL. ADD THE
 VERTICAL DATUM AND CONVERSION EQUATION TO NGVD1929 TO
 THE SHEET.
  
 13. [NOT SATISFIED - SHEETS C-1 AND C-4 SHOW THE STOP
 BAR RIGHT BEHIND THE SIDEWALK ALONG 45TH ST.] MOVE STOP
 SIGN/STOP BAR 4 FEET FROM BACK OF SIDEWALK.
  
 14. [PARTIALLY SATISFIED - SHOW DRIVEWAY APRON WITHIN
 THE RIGHT OF WAY AS CONCRETE] PROVIDE A CROSS SECTION
 OF THE DRIVEWAY. SHOW AND LABEL RIGHT OF WAY (45TH ST),
 SURFACE BREAKS, DIMENSIONS BETWEEN SURFACE BREAK
 POINTS, GENERAL SURFACE SLOPES AND MATERIAL, HIGH POINT
 OF DRIVEWAY AND DISTANCE FROM THE R/W. MINIMIZE THE
 DISTANCE TO THE DRIVEWAY HIGH POINT BY MAXIMIZING THE
 DRIVEWAY SLOPE BEHIND THE SIDEWALK. PROVIDE ADA
 COMPLIANT SIDEWALK ACROSS THE DRIVEWAY APRON.
  
 15. [SATISFIED] PROVIDE PARKING SPACE STRIPING DETAIL
 AS SHOWN IN SECTION 94-485 OF THE CITY'S CODE OF
 ORDINANCES.
  
 16. [SATISFIED] NO SURVEY WAS PROVIDED.
  
 17. [SATISFIED] NO WATER AND SEWER PLAN WAS PROVIDED.
  
 NEW COMMENTS (6/2/2023 SUBMITTAL):
  
 18. ON EVERY SHEET WITH ELEVATION INFORMATION, PROVIDE
 THE VERTICAL DATUM REFERENCE AND CONVERSION EQUATION TO
 NGVD1929.
  
 19. BUILDING OUTLINES ARE NOT SHOWN ON THE CIVIL PLANS.
  
 20. LANDSCAPE PLANS DO NOT SHOW ALL OF THE UTILITIES.
  
  
 TRACY WARD, PE
 SENIOR STORMWATER ENGINEER
 ENGINEERING SERVICES DEPARTMENT