Date Text
2023-05-10 16:08:43PLEASE PROVIDE THE FOLLOWING:
 1. DUMPSTER ENCLOSURE DETAILS FOR SANITATION SERVICE
 (I.E. SOLID WASTE CONTAINER(S) TYPE, COLLECTION
 LOCATION, ETC.). FOR A FREESTANDING SITE DUMPSTER
 ENCLOSURE. THE ENCLOSURE SHALL COMPLY WITH THE LATEST
 REVISION OF CITY OF WEST PALM BEACH GENERAL
 CONSTRUCTION GARBAGE ENCLOSURE STANDARD. GC-7
 2. LOS (LEVEL OF SERVICE ANALYSIS) TO REFLECT THE SOLID
 WASTE VOLUME PRODUCED ALONG WITH THE SIZE, TYPE AND
 QUANTITY OF THE CONTAINER (I.E. DUMPSTER/COMPACTOR)
 THAT WILL BE UTILIZED FOR THE SANITATION SERVICE.
 3. PROVIDE AN AUTOTURN PLAN.?? TRAVEL PATHS SHOULD
 BEGIN OUTSIDE THE SITE ILLUSTRATING THE TURN ONTO THE
 PRIMARY ENTRY ROAD/DRIVE, MANEUVERING AROUND THE SITE,
 AND COMPLETED WITH AN ILLUSTRATION DEMONSTRATING
 EXITING THE SITE. PATHS MUST ILLUSTRATE THE FULL
 VEHICLE SWEPT PATH (INCLUDING WHEEL TRACKS AND
 OUT-TO-OUT VEHICLE OVERHANG SWEEP) AND MUST INDICATE A
 CLEAR, UNOBSTRUCTED TRAVEL AROUND THE SITE WITHOUT
 IMPACT/COLLISIONS TO BUILDINGS, CURBS, LANDSCAPING,
 PARKING SPACES, VEHICLES, ETC???
  
 AUTOTURN EXHIBIT WITH DYNAMIC ENVELOPE AND THE
 VEHICLE'S WHEEL PATH IDENTIFIED WITH DIFFERENT COLORS
 FOR THE SANITATION SERVICE, FRONT LOADER TRUCK WITH THE
 FOLLOWING SPECS:
 - DUAL AXLES
 - TRUCK LENGTH: 35 FT
 - TIRE PATH WIDTH: 8FT
 - DYNAMIC ENVELOPE WIDTH: 11 FT
 - TURNING RADIUS:
 - SAE TURNING RADIUS: 325FT
 - CURB TO CURB DIAMETER: 74 FT
 - WALL TO WAII DIAMETER: 86 3FT
  
 BRUCELY A. JOSEPH
 PUBLIC WORKS PROGRAM MANAGER
 [email protected]
  
  