2023-06-29 16:05:37-EXISTING MANHOLE PROPOSED FOR CONNECTION MUST BE
 REHABBE-EXISTING INLINE GATE VALVE SHOWN IN VICINITY OF
 PORPOSED TAP. VERIFY THAT THERE WILL NOT BE A CONFLUCT
 OR OBSTRUCTION
 -ONSITE FDEP PERMIT WILL BE REQUIRED FOR THE PROPOSED
 FIRE HYFRANT
 -LIST SIZE AND MATERIAL FOR ALL EXISTING AND PROPOSED
 UTILITIES
 -DENOTE THE CITY'S POINT OF SERVICE
 -PROVIDE A PROFILE FOR THE FIRE LINE FROM THE POINT OF
 CONNECTION TO THE POINT OF SERVICE
 -INCLUDE TOP/BOP ELEVATIONS FOR ALL UTILITY CONFLICTS
 -PRINT SHEETS SO THAT THEY ARE TO SCALE ON 11X17 PAPER
 -SHOW ALL UNDERGROUND DRY UTILITIES WITHIN THE PROJECT
 LIMITS
 -SEPARATE TAPS FOR DOMESTIC, FIRE, AND IRRIGATION ARE
 REQUIRED AS TO AVOID SERVICE INTERRUPTIONS DURING
 FUTURE MAINTENANCE AND REPAIRS
 -REFER TO CITY'S STANDARD DETAILS FOR PLACEMENT OF
 ABOVE GROUNT METER/RPZ AND DDCA