| Date |
Text |
| 2023-04-17 19:59:19 | 1) PROVIDE COUNTY TPS LETTER |
| | 2) PROVIDE APPROVAL FROM COUNTY (I.E. EMAIL |
| | CORRESPONDENCE) OR REQUEST A SPECIFIC COMMENT IN THE |
| | TPS LETTER ADDRESSING THE LEFT-TURN LANE REQUIREMENT |
| | 3) PROVIDE A TRANSPORTATION SPECIFIC SITE PLAN FOR THE |
| | GROUND FLOOR. SHOWCASING TRANSPORTATION RELATED |
| | FEATURES (E.G. ROADWAY WIDTHS, DRIVING AISLES, PARKING |
| | STALLS, SIDEWALK, CURB, GUTTER, DRIVEWAY, GATES, |
| | CROSSWALKS, VISIBILITY TRIANGLE, CORNER & DRIVEWAY |
| | SEPARATION DISTANCES, SLOPES, ETC.) PROPERLY LABELED |
| | AND DIMENSIONED. THE SITE PLAN SHOULD BE NAMED T-1.0 |
| | 4) IN THE T-1.0 SITE PLAN, PLEASE SHOWCASE BASIC CURB |
| | DETAILS (E.G. DRIVEWAY, CURB CUTS, PAVEMENT MARKINGS, |
| | PARKING STALLS, ETC.) ON THE OPPOSITE SIDE OF THE ROADS |
| | SURROUNDING THE PROPOSED DEVELOPMENT |
| | 5) PROVIDE A SIGNAGE AND PAVEMENT MARKING PLAN. |
| | INCLUSIVE OF ALL FEATURES WITHIN THE PROPOSED |
| | DEVELOPMENT AND ALONG ALL ROADS FRONTING THE SITE. SUCH |
| | PLAN IS PART OF THE TRANSPORTATION REVIEW AND SHOULD BE |
| | NAMED ACCORDINGLY (E.G. T-1.1 OR T-2.0) |
| | 6) PROVIDE AUTOTURN ANALYSIS FOR GARBAGE TRUCK AND/OR |
| | SERVICE VEHICLES DRIVING IN AND OUT OF THE PROPOSED |
| | DEVELOPMENT WITH VEHICLE DYNAMIC ENVELOPES AND WHEEL |
| | PATHS CLEARLY DISTINCT AND DEFINED IN DIFFERENT COLORS. |
| | PROVIDE THE ANALYSIS IN A SEPARATE SHEET. SUCH PLAN(S) |
| | CONTAINING THE ANALYSIS ARE PART OF THE TRANSPORTATION |
| | REVIEW AND SHOULD BE NAMED ACCORDINGLY (E.G. T1.2, |
| | T-3.0) |
| | 7) PROVIDE ENGINEERING REFERENCE AND SPECS SHEETS FOR |
| | EACH OF THE PROPOSED TRANSPORTATION FEATURES (E.G. |
| | CURB, RAMP, GATE, SIGNAGE, PAVEMENT MARKING, SIGNAL, |
| | ETC.) |
| | 8) IDENTIFY AND DESIGNATE AN EASILY ACCESSIBLE |
| | MICRO-MOBILITY STATION AREA (MINIMUM 8 X 20 FEET) AND |
| | PROVIDE BASIC ELECTRIFICATION READINESS WITH THE |
| | FOLLOWING SPECS: A CONDUIT (2-INCH SCHEDULE 40 PVC) TO |
| | THE POWER SOURCE WITH AN ELECTRICAL PULL BOX (240V / |
| | 10,000W CIRCUIT). PLEASE INSERT THIS FEATURE IN THE |
| | T-1.0 OR T1.1 SITE PLAN |
| | 9) PROVIDE A PARKING TABLE SHOWCASING THE NUMBER OF |
| | REQUIRED AND PROVIDED PARKING SPACES, INCLUSIVE OF ADA |
| | AND BICYCLE ONES |
| | 10) IN THE PAVEMENT, MARKING & SIGN PLAN, PROVIDE A |
| | TABLE SHOWCASING THE NUMBER OF EXISTING AND PROPOSED |
| | ON-STREET PARKING STALLS. PROVIDE THE NUMBER OF METERED |
| | STALLS THAT ARE BEING REMOVED OR RELOCATED, IF ANY |
| | 11) ARE THERE ANY GATES PROPOSED? IF SO, CLEARLY |
| | SHOWCASE THE REQUIRED 20 FEET SETBACK DISTANCE FROM THE |
| | BACK OF THE SIDEWALK |
| | 12) IS VALET SERVICE PROPOSED? IF SO, PROVIDE A |
| | THOROUGH OPERATIONAL ANALYSIS. DETAILS OF THE ANALYSIS |
| | SHOULD BE DISCUSSED DURING THE METHODOLOGY MEETING |
| | 13) ARE THERE ANY BUS STOPS BEING IMPACTED? |
| | 14) IS THE PROPOSED DEVELOPMENT IMPACTING AN EXISTING |
| | BICYCLE FACILITY? |
| | 15) PROVIDE A CONSTRUCTION MANAGEMENT PLAN. PLEASE |
| | REFER TO CITY CODE 86-246 FOR DETAILS. |
| | 16) PER CITY CODE SEC94-111(C)(1): ???IN THOSE CASES |
| | WHERE THE SIDE OF ANY STALL IS ADJACENT TO A WALL, |
| | FENCE, BUILDING, OR OTHER PHYSICAL OBSTRUCTION, THE |
| | STALL WIDTHS SHALL BE INCREASED BY A MINIMUM OF ONE |
| | FOOT. WHERE THERE IS AN OBSTRUCTION ON BOTH SIDES OF |
| | THE STALL, THE STALL WIDTHS SHALL BE INCREASED BY A |
| | MINIMUM OF TWO FEET.??? |
| | 17) LOADING ZONE(S), IF REQUIRED, SHOULD BE PROVIDED |
| | WITHIN THE PROPOSED DEVELOPMENT, NOT ON PUBLIC ROW |
| | |
| | VALERIO ORICCHIO |
| | CITY TRANSPORTATION ENGINEER |
| | 561-494-1092 |
| | [email protected] |
| | |
| |