| Date |
Text |
| 2023-05-10 13:37:46 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL |
| | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION |
| | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE |
| | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT |
| | APPLICATION PROCESSES. |
| | |
| | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE |
| | PLAN APPROVAL: |
| | |
| | 1. THE CITY'S OFFICIAL VERTICAL DATUM PER CITY CODE IS |
| | NGVD1929. THE NAVD1988 VERTICAL DATUM MAY BE USED IF |
| | THE CONVERSION EQUATION BETWEEN NAVD1988 AND NGVD1929 |
| | IS PROVIDED. PROVIDE THE CONVERSION EQUATION ON THE |
| | SURVEY. |
| | |
| | 2. UPDATE ALL FDOT STANDARD INDEX NUMBERS TO FDOT |
| | STANDARD PLAN NUMBERS. |
| | |
| | 3. GENERAL NOTE #31 REGARDING AUSTRALIAN AVE ON SHEET |
| | C-03 IS NOT NEEDED. |
| | |
| | 4. ON THE SWPPP, CONSIDER ADDING FLOATING TURBIDIITY |
| | BARRIER AROUND THE STORM PIPE DISCHARGING INTO THE STUB |
| | CANAL. |
| | |
| | 5. SUGGEST LOCATING YD#2 IN THE LANDSCAPE AREA TO THE |
| | SOUTH AND SLOPING THE ADJOINNG SIDEWALKS ON NORTH, EAST |
| | AND SOUTH SIDES OF LANDSCAPE AREA TOWARD THE LANDSCAPE |
| | AREA. |
| | |
| | 6. MOVE STRUCTURES OUT OF THE SIDEWALKS WHERE POSSIBLE |
| | TO REDUCE THE RISK OF TRIPPING HAZARDS. |
| | |
| | 7. SITE IS WITHIN A SPECIAL FLOOD HAZARD AREA. |
| | STRUCTURES WITHIN A SFHA ARE TO HAVE A MINIMUM OF TWO |
| | FEET OF FREEBOARD ABOVE THE BASE FLOOD ELEVATION OF |
| | 12.1 FT NAVD. |
| | |
| | |
| | |
| | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO |
| | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING |
| | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. |
| | |
| | 1. MODIFY THE SFWMD ERP PERMIT AND PROVIDE A COPY OF |
| | THE SFWMD ERP BEFORE START OF CONSTRUCTION. |
| | |
| | 2. PROVIDE EROSION AND SEDIMENT CONTROL PLAN WITH THE |
| | ENGINEERING PERMIT SUBMITTAL. |
| | |
| | 3. STORMWATER MANAGEMENT CALCULATIONS WILL BE REVIEWED |
| | WITH THE ENGINEERING PERMIT SUBMITTAL. |
| | |
| | TRACY WARD, PE |
| | SENIOR STORMWATER ENGINEER |
| | ENGINEERING SERVICES DEPARTMENT |
| | 561-494-1120 (O) |
| | [email protected] |
| | |
| |