Plan Review Notes
Plan Review Notes For Project Z23010016
Project Number Z23010016
Review Stop STORM
Sequence Number 1
Notes
Date Text
2023-04-12 19:22:13THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL
 DETAILS, DESIGN CALCULATIONS AND THE POLLUTION
 PREVENTION PLAN WILL BE REVIEWED AS PART OF THE
 ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT
 APPLICATION PROCESSES.
  
 THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE
 PLAN APPROVAL:
  
 1. PROPOSED SIDEWALK AND PARKING TO DRAIN TO INTERNAL
 DRAINAGE SYSTEM AND NOT TOWARDS THE CANAL.
  
 2. EXPLAIN WHAT THE DOUBLE STACKED SPOT GRADES
 REPRESENT AS SHOWN ON SHEET SP1 OF 1. EXAMPLES OF THESE
 DOUBLE STACKED GRADES ARE 17.80/17.00, 17.70/16.20,
 17.50/16.00, 17.60/16.10.
  
 3. PROVIDE VERTICAL DATUM AND CONVERSION TO NGVD1929 ON
 SHEET SP1 OF 1. THE CITY???S OFFICIAL VERTICAL DATUM
 PER CITY CODE IS NGVD1929.
  
 4. NO CIVIL PLANS WERE PROVIDED.
  
 TRACY WARD, PE
 SENIOR STORMWATER ENGINEER
 ENGINEERING SERVICES DEPARTMENT
 561-494-1120 (O)
 [email protected]
  