| 2023-01-13 16:58:58 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER |
| | 561-822-1462 |
| | PROJECT: 1545 CENTREPARK CPD RESIDENTIAL Z22100020 |
| | JANUARY 13, 2023 |
| | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND |
| | PROVIDE THE FOLLOWING COMMENTS: |
| | |
| | 1. NOT SATISFIED. PROVIDE INFORMATION IN AN ARBORISTS |
| | REPORT RATING THE CONDITION FOR EACH OF THE TREES AND |
| | PALMS ON SITE AND ADD THE CONDITION IN A COLUMN ON THE |
| | TREE DISPOSITION LIST. ANSI A 300 (PART 5) STANDARDS |
| | SPECIFY EXAMPLES OF CONDITION RATINGS OF GOOD, FAIR, OR |
| | POOR. ALL DATA ON EACH TREE MUST BE PROVIDED WITH |
| | ACCURATE CANOPY DIAMETERS FOR EACH TREE. RELOCATION |
| | ASSESSMENT HAS BEEN PROVIDED, BUT THIS IS NOT AN |
| | ARBORISTS REPORT ON THE DATA NEEDED FOR THE TREES ON |
| | SITE. |
| | 1/13/23 APPLICANT HAS INDICATED THE REPORT WILL BE |
| | SUBMITTED LATER. |
| | 2. PARTIALLY SATISFIED. PROVIDE A DETAIL AND NARRATIVE |
| | FOR INSTALLATION OF TREE PROTECTION BARRIERS FOR THE |
| | TREES TO REMAIN DURING CONSTRUCTION. THERE WILL BE AN |
| | EXTREME LEVEL OF DIFFICULTY TO PROTECT THE REMAINING |
| | TREES DURING CONSTRUCTION OF THE BUILDING AND POSSIBLE |
| | FILL FROM ANY ELEVATION DIFFERENCE FOR THE FINISHED |
| | FLOOR LEVEL. |
| | 1/13/23 PROVIDE NARRATIVE FOR HOW TREES WILL BE |
| | PROTECTED DURING CONSTRUCTION. |
| | 3. NOT SATISFIED. SHEET LP-1 SHOWS A DEFICIT IN TREE |
| | CANOPY MITIGATION. PROVIDE CALCULATIONS IF PAYMENT IN |
| | LIEU IS CHOSEN. |
| | 1/13/23 CURRENT VALUE OF CATEGORY 1 TREE PROVIDING 300 |
| | SQ FT OF CREDIT FOR MITIGATION IS $500.00 |
| | 4. SATISFIED. UPDATE THE FLORIDA FRIENDLY LANDSCAPE |
| | DESIGN OPTIONS CHART TO MAKE THE FOLLOWING CORRECTIONS: |
| | ??? GROUNDCOVER SHOWN HAS NO NATIVE SPECIES, SO DESIGN |
| | OPTION (3)(D) CANNOT BE TAKEN. |
| | |
| | 5. NOT SATISFIED. REVISE THE PLANT LIST TO ALIGN THE |
| | COLUMNS FOR FLORIDA NATIVE PLANTS AND FOR DROUGHT |
| | TOLERANCE LEVEL FOR EACH SPECIES FOR CLARITY. |
| | |
| | 6. SATISFIED. FILL IN NON-NATIVE COLUMN FOR |
| | BOUGAINVILLEA AND CAT PALM. |
| | |
| | 7. SATISFIED. CORRECT THE LANDSCAPE REQUIREMENTS CHART |
| | AND THE PLAN TO SHOW THE 15 FOOT REQUIRED BUFFER ALONG |
| | AUSTRALIAN AVENUE PROPERTY LINE SEGMENT AS A SEPARATE |
| | LINE ON THE CHART. SEE COMMENT #10. |
| | |
| | 8. SATISFIED. PROVIDE SCREENING FOR ALL GROUND MOUNTED |
| | VALVES AND EQUIPMENT. |
| | |
| | 9. NOT SATISFIED. SHOW THE LOCATIONS OF ALL SITE |
| | LIGHTING ON THE LANDSCAPE PLAN AND RESOLVE ANY |
| | CONFLICTS WITH TREES. |
| | 1/13/23 APPLICANT HAS INDICATED THIS WILL BE PROVIDED |
| | LATER. |
| | RESOLUTION NO. 16-21: |
| | |
| | 10. SATISFIED. PER EXHIBIT F, THE WEST PROPERTY LINE |
| | ALONG AUSTRALIAN AVE. REQUIRES A BUFFER WITH A MINIMUM |
| | AVERAGE WIDTH OF 15 FEET. |
| | |
| | 11. NOT SATISFIED. PER EXHIBIT F, APPROVAL FROM THE |
| | ARCHITECTURAL REVIEW BOARD MUST BE PROVIDED FOR THE |
| | LANDSCAPE AND IRRIGATION PROPOSED WHEN FINAL PLANS HAVE |
| | BEEN REVIEWED AND APPROVED. |
| | |
| | 12. SATISFIED. PER EXHIBIT F, PLANT MATERIAL, A MINIMUM |
| | OF 33 PERCENT OF ALL PLANT MATERIALS SHALL BE NATIVE TO |
| | SOUTHERN FLORIDA. PROVIDE VERIFICATION. |
| | |
| | 13. SATISFIED. PER EXHIBIT F, ALL SHRUB AND HEDGE |
| | MATERIAL SHALL BE A MINIMUM OF 24 INCHES UPON PLANTING. |
| | |
| | 14. NOT SATISFIED. SHOW LOCATION OF PUMP EQUIPMENT AND |
| | SOURCE FOR THE IRRIGATION SYSTEM TO MEET CONDITION #11 |
| | REQUIRING USE OF SURFACE WATER FROM LAKES. |
| | 1/13/23 THIS IS REQUIRED FOR SITE PLAN APPROVAL. |
| | |
| | 15. SATISFIED. VERIFY CONDITION #12 IS MET FOR ALL |
| | REQUIREMENTS FOR NATIVE VEGETATION INCLUDING AT LEAST |
| | 50 PERCENT OF THE TREES BEING NATIVE SPECIES ADAPTED TO |
| | SOIL CONDITIONS ON SITE. |
| | |
| | |
| | CONDITIONS OF APPROVAL |
| | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON |
| | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE |
| | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT |
| | SERVICES DEPARTMENT, PLANNING DIVISION. |
| | |
| |