Plan Review Notes
Plan Review Notes For Project Z22100020
Project Number Z22100020
Review Stop L
Sequence Number 1
Notes
Date Text
2022-11-07 16:33:15FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462
 PROJECT: 1545 CENTREPARK CPD RESIDENTIAL Z22100020
 OCTOBER 7, 2022
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 1. PROVIDE INFORMATION WITH THE ARBORISTS REPORT RATING
 THE CONDITION FOR EACH OF THE TREES AND PALMS ON SITE
 AND ADD THE CONDITION IN A COLUMN ON THE TREE
 DISPOSITION LIST. ANSI A 300 (PART 5) STANDARDS SPECIFY
 EXAMPLES OF CONDITION RATINGS OF GOOD, FAIR, OR POOR.
 RELOCATION ASSESSMENT HAS BEEN PROVIDED.
 2. PROVIDE A DETAIL AND NARRATIVE FOR INSTALLATION OF
 TREE PROTECTION BARRIERS FOR THE TREES TO REMAIN DURING
 CONSTRUCTION. THERE WILL BE AN EXTREME LEVEL OF
 DIFFICULTY TO PROTECT THE REMAINING TREES DURING
 CONSTRUCTION OF THE BUILDING AND POSSIBLE FILL FROM ANY
 ELEVATION DIFFERENCE FOR THE FINISHED FLOOR LEVEL.
 3. SHEET LP-1 SHOWS A DEFICIT IN TREE CANOPY
 MITIGATION. PROVIDE CALCULATIONS IF PAYMENT IN LIEU IS
 CHOSEN.
 4. UPDATE THE FLORIDA FRIENDLY LANDSCAPE DESIGN OPTIONS
 CHART TO MAKE THE FOLLOWING CORRECTIONS:
 ??? GROUNDCOVER SHOWN HAS NO NATIVE SPECIES, SO DESIGN
 OPTION (3)(D) CANNOT BE TAKEN.
  
 5. REVISE THE PLANT LIST TO ALIGN THE COLUMNS FOR
 FLORIDA NATIVE PLANTS AND FOR DROUGHT TOLERANCE LEVEL
 FOR EACH SPECIES FOR CLARITY.
  
 6. FILL IN NON-NATIVE COLUMN FOR BOUGAINVILLEA AND CAT
 PALM.
  
 7. CORRECT THE LANDSCAPE REQUIREMENTS CHART AND THE
 PLAN TO SHOW THE 15 FOOT REQUIRED BUFFER ALONG
 AUSTRALIAN AVENUE PROPERTY LINE SEGMENT AS A SEPARATE
 LINE ON THE CHART. SEE COMMENT #10.
  
 8. PROVIDE SCREENING FOR ALL GROUND MOUNTED VALVES AND
 EQUIPMENT.
  
 9. SHOW THE LOCATIONS OF ALL SITE LIGHTING ON THE
 LANDSCAPE PLAN AND RESOLVE ANY CONFLICTS WITH TREES.
  
 RESOLUTION NO. 16-21
  
 10. PER EXHIBIT F, THE WEST PROPERTY LINE ALONG
 AUSTRALIAN AVE. REQUIRES A BUFFER WITH A MINIMUM
 AVERAGE WIDTH OF 15 FEET.
  
 11. PER EXHIBIT F, APPROVAL FROM THE ARCHITECTURAL
 REVIEW BOARD MUST BE PROVIDED FOR THE LANDSCAPE AND
 IRRIGATION PROPOSED WHEN FINAL PLANS HAVE BEEN REVIEWED
 AND APPROVED.
  
 12. PER EXHIBIT F, PLANT MATERIAL, A MINIMUM OF 33
 PERCENT OF ALL PLANT MATERIALS SHALL BE NATIVE TO
 SOUTHERN FLORIDA. PROVIDE VERIFICATION.
  
 13. PER EXHIBIT F, ALL SHRUB AND HEDGE MATERIAL SHALL
 BE A MINIMUM OF 24 INCHES UPON PLANTING.
  
 14. SHOW LOCATION OF PUMP EQUIPMENT AND SOURCE FOR THE
 IRRIGATION SYSTEM TO MEET CONDITION #11 REQUIRING USE
 OF SURFACE WATER FROM LAKES.
  
 15. VERIFY CONDITION #12 IS MET FOR ALL REQUIREMENTS
 FOR NATIVE VEGETATION INCLUDING AT LEAST 50 PERCENT OF
 THE TREES BEING NATIVE SPECIES ADAPTED TO SOIL
 CONDITIONS ON SITE.
  
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  