| 2022-10-13 00:04:11 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL |
| | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION |
| | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE |
| | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT |
| | APPLICATION PROCESSES. |
| | |
| | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE |
| | PLAN APPROVAL: |
| | |
| | 1. BE CONSISTENT WITH THE VERTICAL DATUM USED ON THE |
| | SURVEY AND ON THE ENGINEERING PLANS. THE CITY???S |
| | OFFICIAL VERTICAL DATUM PER CITY CODE IS NGVD1929. THE |
| | NAVD1988 VERTICAL DATUM MAY BE USED IF THE CONVERSION |
| | EQUATION BETWEEN NAVD1988 ABD NGVD1929 IS PROVIDED. |
| | LIST THE VERTICAL DATUM AND CONVERSION EQUATION (IF |
| | APPLICABLE) ON EVERY SHEET WITH ELEVATION INFORMATION. |
| | |
| | 2. PROVIDE A DETAIL OF THE CONTROL STRUCTURE. |
| | |
| | 3. CONSIDER PROVIDING 2 FEET OF OVERHANG FOR THE EAST |
| | PARKING SPACES. SHOW AND LABEL THE PARKING OVERHANG. |
| | |
| | |
| | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO |
| | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING |
| | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. |
| | |
| | 1. DRAINAGE SYSTEM TO BE DESIGNED TO MEET SFWMD ERP |
| | CRITERIA. STORMWATER CALCULATIONS WILL BE REVIEWED WITH |
| | THE ENGINEERING PERMIT SUBMITTAL. |
| | |
| | 2. PROVIDE COPY OF SFWMD ERP PERMIT BEFORE START OF |
| | CONSTRUCTION. |
| | |
| | 3. PROVIDE EROSION AND SEDIMENT CONTROL PLAN WITH THE |
| | ENGINEERING PERMIT SUBMITTAL. |
| | |
| | |
| | TRACY WARD, PE |
| | SENIOR STORMWATER ENGINEER |
| | ENGINEERING SERVICES DEPARTMENT |
| | 561-494-1120 (O) |
| | [email protected] |
| | |
| |
Print |