Plan Review Notes
Plan Review Notes For Project Z22090019
Project Number Z22090019
Review Stop Z
Sequence Number 1
Notes
Date Text
2022-10-06 10:28:2410/6/22 - FAILED
  
  
 PLEASE NOTE THE FOLLOWING PROCESS COMMENTS WHEN
 RESUBMITTING:
 A. WRITTEN RESPONSES TO COMMENTS MADE BY ALL
 DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION.
 B. PROVIDE AN ELECTRONIC COPY OF ALL PLANS AND REQUIRED
 MATERIALS AND 2 SETS OF FOLDED PHYSICAL PLANS, ALONG
 WITH ONE (1) REDUCED COPY (11 IN X 17 IN).
 C. PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO
 ADDITIONAL COMMENTS.
 D. IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE
 ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE
 CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL
 REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION.
 E. PLEASE NOTE THAT YOU ARE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. A RESUBMITTAL FEE OF
 20% OF THE ORIGINAL APPLICATION FEE WILL BE ASSESSED
 AFTER THE FIRST RESUBMITTAL.
  
 REQUIRED MATERIALS MUST BE PROVIDED:
 F. PLEASE PROVIDE LETTERS FROM PUBLIC UTILITIES (AT&T
 TELECOMMUNICATION, FLORIDA PUBLIC UTILITIES, FLORIDA
 POWER & LIGHT COMPANY, COMCAST CABLE COMMUNICATIONS,
 CITY OF WEST PALM BEACH UTILITIES) CONFIRMING THAT THE
 PROPOSED PROJECT DOES NOT ENCROACH INTO THEIR EASEMENTS
 OR OTHERWISE INTERFERE WITH THE PROVISIONS OF THEIR
 SERVICES.
 G. PLEASE PROVIDE A TRAFFIC CONCURRENCY/PERFORMANCE
 STANDARD REVIEW (TPS) LETTER FROM THE PALM BEACH COUNTY
 TRAFFIC DIVISION FOR THE SUBJECT PROJECT.
 H. PLEASE SUBMIT A SUBDIVISION (MAJOR - PLAT/REPLAT)
 APPLICATION.
 I. PLEASE PROVIDE REVISED PLANS ADDRESSING THE REVIEW
 COMMENTS BELOW.
 J. PLEASE PROVIDE/INDICATE/DEMONSTRATE CONSISTENT
 INFORMATION ON ALL THE DIFFERENT PLANS AND REQUIRED
 MATERIALS WITHIN THE APPLICATION PACKET RESUBMITTAL.
  
 PLANS REVIEW COMMENTS MUST BE ADDRESSED:
 1. PLEASE CLARIFY AND CONFIRM IF THE PROPOSED UNITS ARE
 FEE SIMPLE INDIVIDUALLY OWNED OR NOT ON THE REVISED
 PLANS AND MATERIALS, ACCORDINGLY.
 2. IN ACCORDANCE WITH THE CITY???S ZONING AND LAND
 DEVELOPMENT REGULATIONS (ZLDR) SUBSECTION 94-309(G)(3),
 PLEASE IDENTIFY/INDICATE THE PERCENTAGE OF THE PROPOSED
 LOTS AREAS THAT WILL BE CONVEYED TO THE OWNER IN FEE
 SIMPLE TITLE IN THE ???SITE DATA??? SECTION ON SP-1
 SHEET 1 OF 2.
 3. IN ACCORDANCE WITH THE ZLDR SUBSECTION 94-309(G)(3),
 PLEASE IDENTIFY/INDICATE THE PERCENTAGE OF THE PROPOSED
 GROUND FLOOR BUILDING AREAS THAT WILL BE CONVEYED TO
 THE OWNER IN FEE SIMPLE TITLE IN THE ???SITE DATA???
 SECTION ON SP-1 SHEET 1 OF 2.
 4. PLEASE IDENTIFY/INDICATE/DEMONSTRATE/DELINEATE THE
 PROPOSED LOT LINES, LOT WIDTH DIMENSIONS, AND LOT DEPTH
 DIMENSIONS FOR THE INDIVIDUAL UNITS ON THE PLANS,
 ACCORDINGLY. THEREFORE, IDENTIFY/INDICATE/DEMONSTRATE
 THE PROPOSED UNITS??? SETBACK DIMENSIONS FROM THE
 PROPOSED LOT LINES IN THE PLANS, ACCORDINGLY.
 5. IN ACCORDANCE WITH THE ZLDR SUBSECTION 94-309(C),
 PLEASE REVISE THE PLANS TO
 IDENTIFY/INDICATE/DEMONSTRATE ALL PROPOSED LOTS
 ACCESSIBLE VIA PUBLIC RIGHTS-OF-WAY, PUBLIC STREETS,
 PRIVATE STREETS, OR EASEMENTS APPROVED BY THE CITY.
 6. PLEASE COORDINATE WITH THE CITY???S ENGINEERING
 SERVICES DEPARTMENT AND REFER TO THE ZLDR SECTION
 94-342 FOR THE GENERAL DESIGN STANDARDS FOR STREETS,
 EASEMENTS, ETC.
 7. PLEASE IDENTIFY/INDICATE THE PROPOSED MAXIMUM NUMBER
 OF STORIES IN THE ???SITE DATA??? SECTION ON SP-1 SHEET
 1 OF 2.
 8. PLEASE CORRECT THE ???SITE DATA??? SECTION ON SP-1
 SHEET 1 OF 2 BY INDICATING THE MAXIMUM ALLOWED DENSITY
 AS 20.26 DWELLING UNITS PER ACRE.
 9. PLEASE CORRECT THE ???SITE DATA??? SECTION ON SP-1
 SHEET 1 OF 2 BY INDICATING MF20 - TOWNHOUSES PER ZLDR
 SUBSECTION 94-309(G) INSTEAD OF ???NC??? NEXT TO
 ???DEVELOPMENT STANDARDS???.
 10. PLEASE CORRECT THE ???SITE DATA??? SECTION ON SP-1
 SHEET 1 OF 2 BY INDICATING THE MINIMUM REQUIRED
 BUILDING SEPARATION DISTANCE AS 20 FEET.
 11. PLEASE CORRECT THE ???SITE DATA??? SECTION ON SP-1
 SHEET 1 OF 2 BY INDICATING CONSISTENT INFORMATION
 REGARDING THE PROPOSED BUILDING SEPARATION DISTANCES.
 12. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE PROPOSED
 STRUCTURAL INTRUSION SETBACK DIMENSIONS ON SP-1 SHEET 1
 OF 2 TO DEMONSTRATE COMPLIANCE WITH THE ZLDR SUBSECTION
 94-305(B)(2).
 13. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE PROPOSED
 MECHANICAL EQUIPMENT SETBACK DIMENSIONS ON SP-1 SHEET 1
 OF 2 TO DEMONSTRATE COMPLIANCE WITH THE ZLDR SUBSECTION
 94-305(B)(4).
 14. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE DRIVEWAYS
 AND CURB CUTS ADJACENT TO AND ACROSS FROM THE SUBJECT
 PROPERTY ON THE PLANS, ACCORDINGLY.
 15. THE PROPOSED DRIVEWAYS FOR THE INDIVIDUAL UNITS ARE
 NOT MEETING THE MINIMUM DEPTH REQUIREMENT PER THE ZLDR
 SECTION 94-485. THEREFORE, PLEASE REVISE THE PLANS,
 ACCORDINGLY.
 16. IN ACCORDANCE WITH THE PROPOSED NUMBER OF BEDROOMS
 PER UNIT IDENTIFIED/INDICATED/DEMONSTRATED ON SHEET #
 A-301 AND THE ZLDR SECTION 94-486, PLEASE CONFIRM THE
 PROPOSED NUMBER OF BEDROOMS PER UNIT AND REVISE THE
 PARKING CALCULATIONS (IN THE ???SITE DATA??? SECTION ON
 SP-1 SHEET 1 OF 2) AND THE PLANS, ACCORDINGLY.
 17. IN ACCORDANCE WITH THE ZLDR SECTION 94-486, PLEASE
 IDENTIFY/INDICATE/DEMONSTRATE THE REQUIRED AND PROPOSED
 NUMBER OF GUEST PARKING SPACES IN THE PARKING
 CALCULATIONS (IN THE ???SITE DATA??? SECTION ON SP-1
 SHEET 1 OF 2) AND THE PLANS, ACCORDINGLY.
 18. PLEASE COORDINATE WITH THE CITY???S ENGINEERING
 SERVICES, PUBLIC WORKS, AND PARKING ADMINISTRATION
 DEPARTMENTS FOR THE PROPOSED ON-STREET PARKING,
 CONSIDERING THE FACT THAT NOTTINGHAM BOULEVARD IS
 CURRENTLY BEING IMPROVED.
 19. IN ACCORDANCE WITH THE ZLDR SUBSECTION 94-485(Q),
 PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE REQUIRED AND
 PROPOSED NUMBER OF BICYCLE PARKING SPACES IN THE
 PARKING CALCULATIONS (IN THE ???SITE DATA??? SECTION ON
 SP-1 SHEET 1 OF 2) AND THE PLANS, ACCORDINGLY.
 20. PLEASE PROVIDE THE STANDARD CITY DETAILS FOR
 BICYCLE PARKING ON SP-2 SHEET 2 OF 2.
 21. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE MISSING
 ???2???X2??? CONCRETE STEPPING STONE PAVERS??? ON
 SHEETS C2.1 AND C2.2 OF 8 AS IDENTIFIED ON SP-1 SHEET 1
 OF 2.
 22. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE PROPERTY
 LINES AND THE PROPOSED ILLUMINATION INTENSITY TO THE
 PROPERTY LINES ON SHEET L0 TO DEMONSTRATE COMPLIANCE
 WITH THE ZLDR SUBSECTION 94-309(A).
  
  
 KEVIE DEFRANC
 PLANNER - PLANNING DIVISION
 [email protected]
 561-822-1449
  
  Print