| Date |
Text |
| 2023-01-24 11:41:56 | DEVELOPMENT SERVICES DEPARTMENT |
| | CHRIS KIMMERLY, URBAN DESIGN PLANNER |
| | (561) 822-1426 |
| | [email protected] |
| | |
| | 1.) BICYCLE PARKING NOT INCLUDED, PLEASE PROVIDE BIKE |
| | SPACES MEETING THE REQUIRED STANDARDS: |
| | A. 1 BIKE SPACE PER 15 PARKING SPACES? 12 SPACES WITHIN |
| | BUILDING |
| | B. 1 BIKE SPACE PER 100 FT. OF FRONTAGE? 3 SPACE ALONG |
| | ROW/EXTERIOR |
| | BIKE RACKS ARE SHOWN ON DATURA FRONTAGE, PLEASE PROVIDE |
| | DETAILS AS TO THE SPACING BETWEEN RACKS AND THE TYPE OF |
| | RACKS USE TO SECURE THE BIKES. PLEASE DETAIL THE |
| | INTERNAL BIKE STORAGE ROOM FOR RESIDENTS, INCLUDE |
| | DIMENSIONS, SPACING DETAILS, AND METHODS OF SECURING |
| | BIKES. |
| | RESPONSE: PLASE REFER TO SHEET A 1.00, , PROJECT DATA |
| | WAS UPDATED TO SHOW THE NUMBER OF BICYCLE PARKING |
| | SPACES PROVIDED FOR RESIDENTS IN THE PROJECT, SHEET |
| | A0.6.2 INCLUDES DETAILS OF THE BICYCLE RACKS PROPOSED |
| | IN THE PROJECT AND SHEET A3.01 SHOW THE LOCATION OF THE |
| | RESIDENTS BICYCLE STORAGE AND STREET RACKS. |
| | |
| | ZONING 1/19/23: [NOT SATISFIED] SHEET A100 DATA TABLE |
| | IS INCORRECTLY LABELED FOR THE PARKING SECTION. ZONING |
| | IS CWD-10 (CWD 10-12 INCENTIVE DISTRICT). |
| | |
| | PARKING IS REQUIRED WITHIN THIS SUBDISTRICT AT THE |
| | FOLLOWING RATIOS: |
| | |
| | RESIDENTIAL ??? MIN. 1 SPACE PER UNIT PLUS 1 SPACE PER |
| | 20 UNITS FOR GUEST PARKING. MAX. IS 2 SPACES PER UNIT |
| | PLUS 1 SPACE PER 20 UNITS FOR GUEST PARKING. |
| | |
| | RETAIL/COMMERCIAL/RESTAURANT ??? MIN. IS 2 SPACES PER |
| | 1,000 SF. MAX. 4 SPACES PER 1,000 SF. FLOORS 3-12 |
| | PROVIDE 140 UNITS, PARKING CALCULATION ONLY SPECIFIES |
| | 95 SPACES PROVIDED, DOES NOT MEET MINIMUM. |
| | |
| | NOTE BICYCLE PARKING IS REQUIRED, 1 SPACE PER 100 |
| | LINEAR FEET (LOCATION WITHIN ROW) |
| | |
| | PLEASE REVISE DATA TABLE TO CORRECTLY REFLECT REQUIRED |
| | AND PROVIDED PARKING. |
| | |
| | 2. NO FACADE ARTICULATION SHEETS SHOWING COMPLIANCE TO |
| | STANDARDS, PLEASE PROVIDE DETAILS ON FENESTRATION, |
| | TRANSPARENCY, PLANAR BREAKS, ARCHITECTURAL TREATMENTS, |
| | ETC. PLEASE REFERENCE SEC. 94-109 TABLE IV-4 FOR FACADE |
| | ARTICULATION REQUIREMENTS. PLEASE PROVIDE ILLUSTRATIONS |
| | SHOWING COMPLIANCE AND TABULAR CALCULATIONS SHOWING |
| | COMPLIANCE. |
| | RESPONSE: PLEASE REFER TO SHEETS A0.5.1 TO SHEET A0.5.8 |
| | GRAPHIC AND TABULAR INFORMATION WAS INCLUDED TO SHOW |
| | CODE COMPLIANCE WITH FENESTRATION, TRANSPARENCY AND |
| | PLANAR BREAK REQUIREMETS. |
| | ZONING 1/19/23: [NOT SATISFIED] PLEASE PROVIDE THE |
| | ACTIVE USE CALCULATIONS AND TRANSPARENCY CALCULATIONS |
| | FOR THE 120 S DIXIE BUILDING (HISTORICALLY ELIGIBLE |
| | STRUCTURE) AS PART OF SHEET A0.5.3 AND A0.5.8. |
| | |
| | ON SHEET A0.5.5, A0.5.6, AND A0.5.7, THE TOWER PLANAR |
| | BREAK DOES NOT APPLY TO THIS PROJECT, PLEASE REMOVE. |
| | |
| | REGARDING THE GROUND-PODIUM PLANAR BREAK (FLOORS 1-5) |
| | PLEASE ADJUST THE CALCULATIONS AND AREA SHADED IN SHEET |
| | A0.5.6 TO COUNT ONLY THE PORTIONS WHERE THE PRIMARY |
| | FACE OR PLANE OF THE BUILDING IS INTERRUPTED BY A 3 FT. |
| | + PROJECTION OR RECESSED AREA. PLEASE PROVIDE THE |
| | DIMENSION OF THE DEPTH OF THE RECESS OR PROJECTION AS |
| | WELL. |
| | |
| | REQUIREMENTS APPEAR TO BE MET, THE GRAPHIC |
| | REPRESENTATION OR TOTAL CALCULATIONS ARE INCORRECT. |
| | |
| | 3. PRIVATE OPEN SPACE REQUIREMENT IS 25% OF LOT AREA, |
| | REQUIRING 9,788SF. PLEASE INDICATE WHERE THIS SPACE IS |
| | PROVIDED ON THE PLANS, IS THE TERRACE MEETING THIS |
| | REQUIREMENT? PLEASE BE SURE TO LABEL AND INCLUDE THE |
| | PERMITTED PRIVATE OPEN SPACES PER SEC. 94-109 TABLE |
| | IV-6 AND TABLE IV-7. PROPERLY LABEL THE TYPE OF PRIVATE |
| | OPEN SPACE PROVIDED AND BE SURE TO DETAIL HOW THE |
| | REQUIREMENTS ARE MET. |
| | RESPONSE: PLEASE REFER TO SHEETS A0.03, PRIVATE OPENS |
| | SPACE CALCULATION DIAGRAM WAS ADDED. |
| | ZONING 1/19/23: [NOT SATISFIED] PLEASE PROVIDE ON SHEET |
| | A0.03 THE CALCULATION AND BREAKDOWN OF THE PRIVATE OPEN |
| | SPACE REQUIRED AND PROVIDED: |
| | |
| | I.E. REQUIRED 25% LOT AREA = 9810SF, 30% VEGETATED = |
| | 2,943, MAX. 30% OVERHEAD COVER, AND TREE CANOPY 20%. |
| | THEN PROVIDE THE ACTUAL COUNT PROVIDED FOR EACH. |
| | |
| | 4. SHEET A2.00, DOES NOT ACCURATELY REFLECT CURRENT |
| | STREETSCAPE CONDITIONS ALONG S. DIXIE HIGHWAY, THERE |
| | ARE TWO EXISTING ON-STREET PARKING SPACES ALONG THE |
| | WESTERN SIDE OF THE ROAD. |
| | RESPONSE: SITE PLAN WAS UPDATED TO REFLECT CURRENT |
| | STREETSCAPE CONDITIONS ALONG S. DIXIE HIGHWAY |
| | ZONING 1/19/23: [SATISFIED] |
| | |
| | 5. SHEET A2.00 ILLUSTRATES A PROPOSED ON-STREET DROP |
| | OFF, STAFF DOES NOT SUPPORT THE INCLUSION OF THIS |
| | ON-STREET DROP-OFF AS THERE IS NOT ADEQUATE SPACE TO |
| | PROVIDE FOR THE REQUIRED STREETSCAPE LANDSCAPING AND AN |
| | 8FT. CLEAR SIDEWALK. |
| | RESPONSE: PLEASE REFER TO SHEET A200 AND A301, STREET |
| | DROP OFF WAS REMOVED FROM DIXIE HWY. |
| | ZONING 1/19/23: [SATISFIED] |
| | |
| | 6. PLEASE ILLUSTRATE SITE VISIBILITY TRIANGLES FROM THE |
| | DRIVEWAY ACCESS, STAFF WOULD LIKE TO VERIFY THERE ARE |
| | NO OBSTRUCTIONS. |
| | RESPONSE: PLEASE REFER TO SHEET A301, VISIBILITY |
| | TRIANGLES WERE ADDED TO THE DRIVEWAY ACCESS AND NOTE |
| | INDICATING HEIGHT OF THE PLANTERS AND GLASS HANDRAIL |
| | PROPOSED ON THE EMERGENCY EXIT STAIR. |
| | ZONING 1/19/23: [SATISFIED] |
| | |
| | NOTE: SITE VISIBILITY CAN BE ADJUSTED TO BE FROM THE |
| | PROPERTY LINE INTERSECTION WITH THE DRIVEWAY. SEE SEC. |
| | 94-305 FOR MORE INFORMATION OR REFER TO FIGURE X-1. |
| | |
| | 7. PLEASE INCLUDE AN FAR DIAGRAM, ILLUSTRATING WHICH |
| | ROOMS ARE COUNTED TOWARD FAR AND THOSE THAT ARE NOT. |
| | PLEASE ALSO PROVIDE A TABULAR BREAKDOWN OF THESE SPACES |
| | AND FAR CALCULATIONS. SHEET A0.04 SEEMS TO PROVIDE SOME |
| | DETAIL BUT IT IS NOT CLEAR AS TO WHAT IS OR ISN???T |
| | COUNTED. THE COLOR COORDINATION IS NOT CLEAR. PLEASE |
| | NOTE FAR CALCULATIONS ARE THE SAME AS GBA. PER SECTION |
| | 94-109. GROSS BUILDING AREA MEANS THE TOTAL FLOOR AREA |
| | OF A BUILDING, INCLUDING AIR-CONDITIONED OR FULLY |
| | ENCLOSED STORAGE SPACES, ENCLOSED AREAS ON THE ROOFTOP, |
| | SUCH AS BATHROOMS AND LOBBIES, STAIRS AND ELEVATOR |
| | AREAS, AND EXTERNAL UNENCLOSED CIRCULATION AREAS. THE |
| | GROSS BUILDING AREA DOES NOT INCLUDE PARKING AREAS; |
| | UNENCLOSED COLONNADES, PORCHES AND BALCONIES; |
| | MECHANICAL AND ELECTRICAL SPACES; AND TRASH ROOMS. |
| | STORAGE SPACES WITHOUT WINDOWS AND ENCLOSED BY SURFACES |
| | THAT ALLOW FOR NATURAL VENTILATION OR OUTSIDE AIR |
| | CIRCULATION SHALL NOT BE INCLUDED. GROSS BUILDING AREA |
| | REQUIREMENTS: |
| | |
| | 1. ANY PORTION OF THE PARKING AREA WHICH EXCEEDS THE |
| | MAXIMUM PARKING RATIO SHALL BE INCLUDED IN THE |
| | CALCULATIONS OF GROSS BUILDING AREA. THIS SHALL INCLUDE |
| | STALLS AND ALL ASSOCIATED CIRCULATION AREAS. |
| | 2. PARKING LOCATED BELOW GRADE SHALL NOT BE COUNTED AS |
| | PART OF THE GROSS BUILDING AREA. |
| | 3. THE GROSS BUILDING AREA SHALL BE MEASURED FROM THE |
| | OUTSIDE FACE OF EXTERIOR WALLS. |
| | RESPONSE: PLEASE REFER TO SHEETS A0.04.2 INFORMATION |
| | RELATED TO FAR CALCULATIONS WAS INCLUDED. |
| | |
| | ZONING 1/19/23: [NOT SATISFIED] FAR CALCULATION DOES |
| | INCLUDE ELEVATOR WELLS AND STAIRCASES. FAR CALCULATION |
| | IS BASED UPON THE STANDARDS WITHIN THE DEFINITION FOR |
| | GROSS BUILDING AREA ??? SEC. 94-109. PLEASE REVISE |
| | CALCULATIONS. |
| | |
| | PLEASE PROVIDE THE FAR FOR THE HISTORICALLY ELIGIBLE |
| | STRUCTURE AS WELL, THIS BUILDING COUNTS TOWARDS THE |
| | TOTAL DEVELOPMENT CALCULATION FOR THE ENTIRE PROJECT |
| | SITE/LOT. PLEASE BE SURE THIS GROSS BUILDING AREA AND |
| | FAR IS INCLUDED ON SHEET A100. |
| | |
| | 8. BECAUSE THE PROJECT IS SEEKING TO UTILIZE TDRS AND |
| | THE HEIGHT/FAR INCENTIVE, PER SECTION. 94-131 ELIGIBLE |
| | HISTORIC STRUCTURES LOCATED WITHIN THE SUBJECT SITE ARE |
| | PRESERVED ACCORDING TO THE SECRETARY OF INTERIOR |
| | STANDARDS, AND INTEGRATED AS PART OF THE NEW |
| | DEVELOPMENT IN A MANNER WHICH MAINTAINS THE INTEGRITY |
| | OF THE HISTORIC STRUCTURE. AS SUCH, PLEASE INCLUDE |
| | PLANS, DETAILS, ELEVATIONS, AND ANY |
| | IMPROVEMENTS/RENOVATIONS TO THE DATURA STATION |
| | BUILDING. |
| | RESPONSE: PLEASE REFER TO SHEETS A0.7.1 A NEW SHEET WAS |
| | INCLUDED DESCRIBING THE SCOPE OF IMPROVEMENTS TO THE |
| | HISTORINC BUILDING. |
| | ZONING 1/19/23: [SATISFIED] |
| | |
| | 9. PLEASE OVERLAY AND PROVIDE SETBACK LINES ON SITE |
| | PLANS, FLOOR PLANS, AND ELEVATION DRAWINGS. |
| | RESPONSE: ALL DRAWINGS WERE UPDATED TO SHOW PROPERTY |
| | LINE AND SETBACKS IN BOTH FLOOR PLANS AND ELEVATIONS |
| | DRAWINGS |
| | ZONING 1/19/23: [PARTIALLY SATISFIED] SETBACKS SHOWN ON |
| | DRAWINGS, HOWEVER GROUND FLOOR SETBACK ALONG DATURA |
| | INCORRECTLY MEASURED. SETBACK IS FROM THE BACK OF THE |
| | CURB. PLANS SHOW FROM INSIDE ON-STREET PARKING. SHEET |
| | A2.00, SHEET A3.01, SHEET A4.02, SHEET A4.03, |
| | |
| | 10. PLEASE PROVIDE ACTIVE USE DIAGRAMS AND TABULAR |
| | CALCULATIONS, PLEASE NOTE PER SEC. 94-109: ACTIVE USE |
| | MEANS A USE WITHIN AN ENCLOSED BUILDING DESIGNED FOR |
| | HUMAN OCCUPATION WITH A DIRECT VIEW TO ADJACENT STREETS |
| | OR PUBLIC OPEN SPACE. ACTIVE USE REQUIREMENTS: |
| | 1. ACTIVE USES ARE REGULATED AS A PERCENTAGE OF THE |
| | BUILDABLE LOT FRONTAGE. IN THOSE CASES WHERE PUBLIC |
| | OPEN SPACE IS PROVIDED ALONG THE FRONTAGE LINE, THE |
| | OPEN SPACE MAY BE COUNTED AS ACTIVE USE AS LONG AS |
| | ACTIVE USES ARE PROVIDED ON THE FIRST FLOOR OF THE |
| | BUILDING ADJOINING THE PUBLIC OPEN SPACE. |
| | |
| | RESIDENTIAL AMENITIES NOT INTENDED TO ATTRACT |
| | PEDESTRIAN ACTIVITY SHALL NOT BE PERMITTED TO COUNT AS |
| | THE MINIMUM ACTIVE USE REQUIREMENT IN THE GROUND FLOOR |
| | ALONG PRIMARYPEDESTRIAN STREETS, UNLESS OPEN TO THE |
| | GENERAL PUBLIC. SUCH AMENITIES INCLUDE, BUT ARE NOT |
| | LIMITED TO GYMS, MOVIE ROOMS, AND YOGA ROOMS. |
| | RESPONSE: PLEASE REFER TO SHEET A0.5.8 GRAPHIC AND |
| | TABULAR INFORMATION WAS INCLUDED TO SHOW CODE |
| | COMPLIANCE. |
| | ZONING 1/19/23: [PARTIALLY SATISFIED] PLEASE INCLUDE |
| | THE HISTORIC BUILDING WITHIN THE ACTIVE USE |
| | CALCULATIONS FOR THE DATURA ST. FRONTAGE AND PROVIDE |
| | THE S DIXIE HWY ACTIVE USE CALCULATIONS AS WELL. PLEASE |
| | CLARIFY WITHIN THE TABULAR DATA THE LINEAR LENGTH OF |
| | ACTIVE FRONTAGE AND THE PERCENTAGE, CURRENTLY ONLY |
| | SHOWS THE TRANSPARENCY AND PERCENTAGE. |
| | |
| | 11. DUE TO THE INCLUSION OF STACKERS, PER SEC. 94-111 |
| | (K.): MECHANICAL AND AUTOMATED PARKING. PARKING |
| | STRUCTURES WITH MECHANICAL PARKING SHALL PROVIDE A |
| | COMMERCIAL ATTENDANT DURING THE OPERATING HOURS OF THE |
| | FACILITY. SUCH OPERATION SHALL BE ENFORCED THROUGH A |
| | RESTRICTIVE COVENANT RECORDED IN THE PUBLIC RECORDS. |
| | ALL RESTRICTIVE COVENANTS AND OTHER DOCUMENTS REQUIRED |
| | TO BE RECORDED SHALL BE ON CITY APPROVED FORMS, AND |
| | RECORDED IN THE PUBLIC RECORDS. |
| | |
| | PLEASE PROVIDE DETAIL OF THE STACKERS. |
| | RESPONSE: PLEASE REFER TO SHEET A300, STACKERS WERE |
| | REMOVED FROM THE PARKING GARAGE AND NO COMMERCIAL |
| | ATTENDANT WILL BE REQUIRED. |
| | ZONING 1/19/23: [SATISFIED] |
| | RESTRICTIVE COVENANT AND RECORDED DOCUMENTATION WILL BE |
| | A CONDITION OF APPROVAL. |
| | |
| | 12. PLEASE PROVIDE PARKING STRIPING AND DIMENSION |
| | DETAIL PER FIGURE XV-2 IN SECTION 94-485 |
| | RESPONSE: PLEASE REFER TO SHEET A0.6.0, A300, A301, |
| | PARKING SPACE DETAIL WAS ADDED TO SHOW PARKING SPACES |
| | DIMS AND STRIPING DETAIL AS PER SEC.94-485, FIG. XV-2 |
| | ZONING 1/19/23: [SATISFIED] |
| | |
| | 13. FOR RESIDENTIAL USES, TANDEM PARKING, IF PROVIDED, |
| | MAY COUNT AS TWO SPACES, PROVIDED BOTH SPACES ARE |
| | DEDICATED TO THE SAME RESIDENTIAL UNIT, AND A |
| | RESTRICTIVE COVENANT IS RECORDED ON CITY APPROVED |
| | FORMS, AND RECORDED IN THE PUBLIC RECORDS. |
| | RESPONSE: NOTED |
| | ZONING 1/19/23: [SATISFIED] |
| | |
| | 14. ELEVATION DRAWINGS SHOW THE PARKING RAMPS AT 16%. |
| | PARKING RAMP MAXIMUM SLOPE. MAXIMUM SLOPES FOR PARKING |
| | RAMPS SHALL BE IN ACCORDANCE WITH ADA REQUIREMENTS AND |
| | SHALL NOT EXCEED SIX PERCENT. NON-PARKING RAMPS SHALL |
| | NOT EXCEED 16 PERCENT. IF THE RAMP IS GREATER THAN 14 |
| | PERCENT, A BREAK-OVER TRANSITION SHALL BE REQUIRED. THE |
| | PREFERRED STANDARD IS TEN PERCENT FOR NON-PARKING RAMP |
| | SLOPES. |
| | RESPONSE: PLEASE REFER TO SHEETS A300, A301, A500, A |
| | 501, NOTES INDICATING THE RAMP BREAK AT THE BEGINNING |
| | AND THE END OF THE RAMP WERE INCLUDED (RAMP TRANSITION |
| | ??) |
| | ZONING 1/19/23: [SATISFIED] |
| | |
| | |
| | 15. PLEASE ILLUSTRATE THE BREAK-OVER TRANSITION SPACE. |
| | RESPONSE: PLEASE REFER TO SHEETS A300, A301, A500 AND |
| | A501, A NOTE INDICATING THE RAMP TRANSITIONS AT THE |
| | BEGINNING AND END PORTION WAS INCLUDED. |
| | ZONING 1/19/23: [SATISFIED] |
| | |
| | ZONING 1.19.23 ??? NEW COMMENTS: |
| | |
| | 1. THE HISTORICALLY ELIGIBLE STRUCTURE FRONTING DIXIE |
| | MUST BE INCLUDED WITHIN ALL BUILDING REQUIREMENT AND |
| | SITE CALCULATIONS. INCLUDING BUT NOT LIMITED TO: FAR, |
| | BUILDING FOOTPRINT, LOT COVERAGE, GROSS BUILDING AREA, |
| | AND PARKING CALCULATIONS. BE SURE TO UPDATE ALL |
| | ACCOMPANYING SHEETS AND DATA TABLES. |
| | |
| | 2. ON SHEET A2.00 PLEASE ADDRESS GRAPHIC ISSUES WITH |
| | MICROMOBILITY AND BIKE RACKS LOCATED WITHIN TREES, |
| | PLEASE CLARIFY WHAT THE SQUARE ITEMS ARE BETWEEN THE |
| | TREES AND WITHIN THE LANDSCAPE STRIP (ARE THESE |
| | TREEGRATES OR CONCRETE PADS FOR THE BIKES?) |
| | |
| | 3. STREETSCAPE ALONG DATURA STREET DOES NOT APPEAR TO |
| | MEET THE MAXIMUM SPACING OF TREES PER SEC. |
| | 94-113(D.)(2.) MAXIMUM ALLOWED IS 30 FT. ON CENTER. |
| | TREES ON EITHER SIDE OF DRIVEWAY APPEAR TO EXCEED 30 |
| | FT. |
| | |
| | 4. ON SHEET A2.00 AND A3.01, PLEASE CLARIFY HOW THE |
| | SURFACE PARKING ON THE GROUND LEVEL WORKS? IT APPEARS |
| | THAT THERE ARE STRUCTURAL COLUMNS OR POSTS WITHIN THE |
| | 5??? REAR SETBACK. PLEASE PROVIDE DETAILS OF THE |
| | OVERHEAD TRELLIS STRUCTURE. |
| | |
| | 5. PER SEC. 94-113(F.) SURFACE PARKING LOTS. ALL |
| | OFF-STREET SURFACE PARKING LOTS SHALL MEET THE |
| | FOLLOWING LANDSCAPING REQUIREMENTS: |
| | |
| | A) SETBACKS AND LANDSCAPE BUFFER. SURFACE PARKING LOTS |
| | SHALL MEET THE MINIMUM GROUND FLOOR SETBACK |
| | REQUIREMENTS AS PROVIDED IN THE SUBDISTRICT BUILDING |
| | REQUIREMENTS TABLE. A FIVE-FOOT LANDSCAPE BUFFER SHALL |
| | BE PROVIDED IN ADDITION TO THE GROUND FLOOR SETBACK TO |
| | VISUALLY SCREEN PARKING AREAS. THE LANDSCAPE BUFFER |
| | SHALL BE COMPRISED OF A HEDGE PLANTED AT TWO-FOOT TO |
| | THREE-FOOT INTERVALS AND MAINTAINED AT A MAXIMUM HEIGHT |
| | OF 36 INCHES AT MATURITY. SHADE TREES SHALL BE PLANTED |
| | AT 30-FOOT INTERVALS. A FIVE-FOOT LANDSCAPE BUFFER |
| | SHALL ALSO BE PROVIDED MEETING THESE REQUIREMENTS FOR |
| | THE ENTIRE PERIMETER OF THE SURFACE LOT. SURFACE |
| | PARKING AREAS LOCATED BEHIND BUILDINGS ARE EXEMPT FROM |
| | THE FRONT SETBACK LANDSCAPE REQUIREMENTS. |
| | |
| | B) TERMINAL ISLANDS, INTERIOR ISLANDS AND DIVIDER |
| | MEDIANS. ALL OTHER PARKING AREA LANDSCAPING SHALL MEET |
| | THE REQUIREMENTS OF CHAPTER XIV. |
| | |
| | PLEASE REVISE PLANS TO PROVIDE THE 5??? LANDSCAPE |
| | BUFFER FOR PARKING. |
| | |
| |
Print |