Plan Review Notes
Plan Review Notes For Project Z22090015
Project Number Z22090015
Review Stop TRAFFIC
Sequence Number 1
Notes
Date Text
2022-10-13 04:06:28TRAFFIC COMMENTS
 1) SETUP A METHODOLOGY MEETING
 2) PROVIDE A FULL DETAILED TRAFFIC ANALYSIS. NOTE: THIS
 SHOULD BE A SEPARATE DOCUMENT FROM THE TRAFFIC IMPACT
 STATEMENT
 3) PROVIDE LATEST SITE PLAN IN THE ANALYSIS
 4) PROVIDE COUNTY TPS LETTER, ONCE RECEIVED
 5) PROVIDE VALID TRANSPORTATION DEMAND MANAGEMENT (TDM)
 MEASURES
 SITE COMMENTS
 6) PROVIDE A TRANSPORTATION SPECIFIC SITE PLAN FOR THE
 GROUND FLOOR. SHOWCASING TRANSPORTATION RELATED
 FEATURES (E.G. ROADWAY WIDTHS, DRIVING AISLES, PARKING
 STALLS, SIDEWALK, CURB, GUTTER, DRIVEWAY, GATES,
 CROSSWALKS, VISIBILITY TRIANGLE, CORNER & DRIVEWAY
 SEPARATION DISTANCES, SLOPES, ETC.) PROPERLY LABELED
 AND DIMENSIONED
 7) IN THE TRANSPORTATION SITE PLAN, PLEASE SHOWCASE
 BASIC CURB DETAILS (E.G. DRIVEWAY, CURB CUTS, PAVEMENT
 MARKINGS, PARKING STALLS, ETC.) ON THE OPPOSITE SIDE OF
 THE ROADS SURROUNDING THE PROPOSED DEVELOPMENT
 8) PROVIDE A SIGNAGE AND PAVEMENT MARKING PLAN.
 INCLUSIVE OF ALL FEATURES WITHIN THE PROPOSED
 DEVELOPMENT AND ALONG ALL ROADS FRONTING THE SITE
 9) PROVIDE AUTOTURN ANALYSIS FOR GARBAGE TRUCK VEHICLES
 10) PROVIDE ENGINEERING REFERENCE AND SPECS SHEETS FOR
 EACH OF THE PROPOSED TRANSPORTATION FEATURES (E.G.
 CURB, RAMP, GATE, SIGNAGE, PAVEMENT MARKING, SIGNAL,
 ETC.)
 11) IDENTIFY AND DESIGNATE AN EASILY ACCESSIBLE
 MICRO-MOBILITY STATION AREA (MINIMUM 8 X 20 FEET) AND
 PROVIDE BASIC ELECTRIFICATION READINESS WITH THE
 FOLLOWING SPECS: A CONDUIT (2-INCH SCHEDULE 40 PVC) TO
 THE POWER SOURCE WITH AN ELECTRICAL PULL BOX (240V /
 10,000W CIRCUIT)
 12) PROVIDE A PARKING TABLE SHOWCASING THE NUMBER OF
 REQUIRED AND PROVIDED PARKING SPACES, INCLUSIVE OF ADA
 AND BICYCLE ONES
 13) ARE THERE ANY VEHICULAR GATES PROPOSED WITHIN
 20-FEET FROM THE BACK OF THE SIDEWALK?
 14) IS VALET SERVICE PROPOSED? IF SO, PROVIDE AN
 OPERATIONAL ANALYSIS. DETAILS OF THE ANALYSIS SHOULD BE
 DISCUSSED DURING THE METHODOLOGY MEETING
 15) EXISTING SIDEWALK ON DATURA IS 10-FEET WIDE, THAT
 MEASUREMENT SHOULD BE PRESERVED IF NOT EXCEEDED
 16) PER CITY CODE SEC 94-111(Q)(2): NON-PARKING RAMPS
 SHALL NOT EXCEED 16 PERCENT. IF THE RAMP IS GREATER
 THAN 14 PERCENT, A BREAK-OVER TRANSITION SHALL BE
 REQUIRED. THE PREFERRED STANDARD IS TEN PERCENT FOR
 NON-PARKING RAMP SLOPES. PLEASE PROVIDE SLOPE
 PERCENTAGES FOR EACH RAMP AND CONFORM TO CODE
 PERTAINING THE BREAK-OVER TRANSITION
 17) PER CITY CODE SEC 94-111(C)(1): IN THOSE CASES
 WHERE THE SIDE OF ANY STALL IS ADJACENT TO A WALL,
 FENCE, BUILDING, OR OTHER PHYSICAL OBSTRUCTION, THE
 STALL WIDTHS SHALL BE INCREASED BY A MINIMUM OF ONE
 FOOT. WHERE THERE IS AN OBSTRUCTION ON BOTH SIDES OF
 THE STALL, THE STALL WIDTHS SHALL BE INCREASED BY A
 MINIMUM OF TWO FEET. PROVIDE DIMENSIONS FOR EACH
 PARKING STALL ADJACENT TO A WALL OR OBSTRUCTIONS
  
 VALERIO ORICCHIO
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]
  