| 2022-12-13 10:38:44 | 1. VARIANCE REQUEST FOR BUILDING FOOTPRINT LEVEL 6-7 |
| | (MAX. 60%) PROPOSED AT 63%. PER SECTION 95-54 (D.)(4).) |
| | UNAUTHORIZED VARIANCES. THE DAC IS NOT AUTHORIZED TO |
| | GRANT VARIANCES FOR ANY OF THE FOLLOWING: (E.) AN |
| | INCREASE IN THE MAXIMUM BUILDING FOOTPRINT ABOVE THE |
| | MAXIMUM FOOTPRINT ALLOWED BY THE URBAN REGULATIONS. |
| | |
| | RESPONSE: THE APPLICANT BELIEVES A VARIANCE CAN BE |
| | GRANTED. WE HAVE REQUESTED A MEETING TO DISCUSS. |
| | |
| | ZONING REVIEW 12/2/22 ??? [SATISFIED] APPLICANT NO |
| | LONGER ASKING FOR FOOTPRINT VARIANCE, VARIANCE IS FROM |
| | SECTION 94-132(E.)(3.)(C.) FOR FUTURE ROW AREA IN |
| | BUILDING CALCULATIONS. |
| | |
| | 2. WHAT IS THE TOTAL SQUARE FOOTAGE FOR OFFICE SPACE |
| | AND RETAIL? JUSTIFICATION LETTER STATES OFFICE AT |
| | 425,798 SF; SHEET A0.01 STATES 378,137 SF; PLEASE |
| | CLARIFY SO STAFF MAY VERIFY PARKING REQUIREMENTS. |
| | RETAIL IN JUSTIFICATION LETTER IS 9,369 SF; SHEET A0.01 |
| | STATES 9,161 SF. PARKING COUNT WILL HAVE TO BE ADJUSTED |
| | TO MEET RESPECTIVE REQUIREMENTS, THE RATIOS PER USE |
| | PROVIDED ON A0.01 ARE CORRECT. |
| | |
| | RESPONSE: THE GROSS BUILDING AREA PER USE AND OVERALL |
| | FAR IS CLARIFIED ON REVISED SHEET A0.01 AND THE |
| | JUSTIFICATION STATEMENT. SEE ALSO SHEET A0.10 BUILDING |
| | AREAS FOR FULL GROSS BUILDING AREA TABULAR PER USE. |
| | |
| | PER SECTION 94-111 OF THE ZONING CODE, PARAGRAPH B.2., |
| | ???PARKING REQUIREMENT CALCULATIONS SHALL BE BASED ON |
| | NET INTERIOR AREA.??? NET INTERIOR AREA (OFFICE) OF |
| | 378,137 SF IS CORRECT AS SHOWN IN THE PARKING TABULAR |
| | TABLE ON SHEET A0.01. NET INTERIOR AREA (RETAIL) OF |
| | 9,161 SF IS CORRECT AS SHOWN IN THE PARKING TABULAR |
| | TABLE ON SHEET |
| | A0.01. SEE ALSO SHEET A0.09 NET INTERIOR AREA FOR FULL |
| | TABULAR AND DIAGRAMS. |
| | |
| | ZONING REVIEW 12/2/22 ??? [NOT SATISFIED] DEFICIENT 180 |
| | SPACES FOR OFFICE USE. MIN. REQ. 946 PROVIDING 766. |
| | (19% REDUCTION) |
| | |
| | SEC. 94-485 - ALL SMALL CAR PARKING SPACES SHALL BE |
| | MARKED WITH INDIVIDUAL SIGNS STATING "SMALL CARS ONLY." |
| | SMALL CAR PARKING SPACES SHALL HAVE DOUBLE STRIPING ON |
| | EACH SIDE OF THE SPACE. |
| | |
| | 3. PLEASE PROVIDE DIMENSIONS OR CALLOUTS SPECIFYING |
| | DEPTH OF ALL SETBACKS ON SITE PLANS, FLOOR PLANS, AND |
| | ELEVATIONS. MINIMUM AND MAXIMUM SETBACKS SHOW. |
| | A. CONDITIONAL SETBACK FOR PARKING USES ABOVE THE 5TH |
| | FLOOR; SHEET A1.06 ONLY SHOWS EVERNIA STREET SET BACK |
| | (PLEASE LABEL REQUIRED 27 FT FROM BACK OF THE CURB) |
| | ZONING REVIEW 12/2/22 ??? [SATISFIED] VARIANCE |
| | REQUESTED. |
| | |
| | B. REQUIRED CONDITIONAL SETBACK ALONG FERN AND |
| | QUADRILLE PLAZA DR. IS 31 FT (PLEASE LABEL ON SHEET |
| | A1.06 AND A1.07) |
| | ZONING REVIEW 12/2/22 ??? [SATISFIED] VARIANCE |
| | REQUESTED. |
| | |
| | C. PLEASE LABEL OR PROVIDE THE FEC ROW ABUTMENT |
| | SETBACKS AND CONDITIONAL SETBACKS ON SHEET A0.05 AND |
| | A1.01 ONWARD. |
| | |
| | RESPONSE: DIMENSIONS AND CALLOUTS HAVE BEEN ADDED TO |
| | THE DRAWINGS AS REQUESTED. |
| | ZONING REVIEW 12/2/22 ??? [SATISFIED] VARIANCE |
| | REQUESTED. |
| | |
| | 4. SHEET A0.08 FAR |
| | A. LEVEL 1 FAR- FAR COUNT NEEDS TO INCLUDE STORAGE |
| | SPACE ADJACENT TO PARKING RAMP |
| | B. LEVEL 2 FAR- PORTION OF NORTHEAST STAIRWELL NOT |
| | SHOWN AS IT IS ON A1.02, PORTION NEEDS TO BE COUNTED IN |
| | FAR |
| | C. MINOR NOTE: SHEET A1.03 DOESN'T SHOW SOUTHERN |
| | ELEVATOR AS YELLOW SHADING FOR CIRCULATION |
| | D. LEVEL 4 FAR- PORTION OF NORTHWEST STAIRWELL NOT |
| | SHOWN AS IT IS ON A1.04, PORTION NEEDS TO BE COUNTED IN |
| | FAR |
| | E. PENTHOUSE FAR- ROOFTOP ON A1.26 SHOWS UNLABELED ROOM |
| | BELOW THE ELEVATOR OVERRUNS, PLEASE LABEL AND IF NOT |
| | MECHANICAL, SPACE WILL COUNT TOWARD FAR. |
| | |
| | RESPONSE: PLEASE SEE SHEETS A0.08, A1.03, AND A1.26 FOR |
| | REVISIONS. SEE ALSO UPDATED FAR DATA ON SHEET A0.01. |
| | ZONING REVIEW 12/2/22 ??? [SATISFIED] |
| | |
| | 5. PUBLIC OPEN SPACE REQUIREMENT NEEDS TO BE ADJUSTED. |
| | 3% REQUIREMENT FOR LOTS 50,000- 80,000SF; TOTAL |
| | REQUIRED 2,292 SF PLUS THE ADDITIONAL 3,501 SF FROM THE |
| | ALLEY ABANDONMENT 1:1 REPLACEMENT. TOTAL REQUIRED 5,793 |
| | SF. PLEASE ADJUST TABLE ON SHEET A0.06 OR LP-1 TO |
| | REFLECT THE CORRECT NUMBER. |
| | |
| | RESPONSE: PUBLIC OPEN SPACE CALCULATIONS ON SHEETS |
| | LP-1, LP-2 AND A0.06 ARE CORRECT. PARCEL 1 + PARCEL 2 + |
| | PARCEL 3 AREAS (PER SURVEY) = 26,629 SF + 39,621 SF + |
| | 6,656 SF = 72,906 SF X .03 = 2,187 SF. PLUS 3,501 SF |
| | (PARCEL 4 AT 1:1) = 5,688 SF TOTAL |
| | REQUIRED. |
| | ZONING REVIEW 12/2/22 ??? [SATISFIED] |
| | |
| | 6. WILL THE QUADRILLE PLAZA DRIVE RIGHT-OF-WAY BE A |
| | DEDICATED ROW? WHAT IS THE FINAL ROW WIDTH? PLEASE |
| | INDICATE ROW LINE ON PLANS, AS IT IMPACTS SETBACKS AND |
| | SITE CONFIGURATION. PLEASE PROVIDE DETAILED DIMENSIONS |
| | AND CONDITIONS OF THE QUADRILLE PLAZA DR. EXTENSION |
| | (SIDEWALK, TRAVEL LANE, LANDSCAPE BUFFERS, |
| | PLANTERS/LANDSCAPE BEDS, ETC.) ON SITE AND GROUND FLOOR |
| | PLANS, AS IS SHOWN IN CIVIL PLANS. |
| | |
| | RESPONSE: THE APPLICANT IS OPEN TO DISCUSSING WHETHER |
| | IT WILL BE A DEDICATED ROW OR EASEMENT. SEE SHEET A0.05 |
| | FOR PROPOSED 60??? ROW FOR QUADRILLE PLAZA DRIVE. A |
| | 16??? SETBACK LINE IS SHOWN FROM BACK OF CURB. |
| | ZONING REVIEW 12/2/22 ??? [SATISFIED] |
| | 60' ROW SHALL BE A DEDICATION OR PUBLIC ACCESS |
| | EASEMENT. |
| | |
| | 7. REMOVAL OF METERED ON-STREET PARKING WILL INCUR A |
| | REMOVAL FEE. PERMANENT REMOVAL FEE INCLUDED WITHIN |
| | RESOLUTION 191-22, $24,000 PER SPACE. PLEASE SPEAK WITH |
| | ED DAVIS- PARKING ADMINISTRATOR FOR ANY QUESTIONS |
| | REGARDING THE REMOVAL PROCESS OR FEES. |
| | |
| | RESPONSE: ACKNOWLEDGED. THE PROJECT WILL REMOVE 11 |
| | SPACES AND WORK WITH ED DAVIS AT PARKING ON THIS ISSUE. |
| | ZONING REVIEW 12/2/22 ??? [SATISFIED] |
| | REMOVAL OF PARKING TO BE DISCUSSED FURTHER WITH PARKING |
| | ADMIN. |
| | |
| | 8. PLEASE NOTE; IN THOSE CASES WHERE THE SIDE OF ANY |
| | PARKING STALL IS ADJACENT TO A WALL, FENCE, BUILDING, |
| | OR OTHER PHYSICAL OBSTRUCTION, THE STALL WIDTHS SHALL |
| | BE INCREASED BY A MINIMUM OF ONE FOOT. WHERE THERE IS |
| | AN OBSTRUCTION ON BOTH SIDES OF THE STALL, THE STALL |
| | WIDTHS SHALL BE INCREASED BY A MINIMUM OF TWO FEET. |
| | |
| | RESPONSE: ACKNOWLEDGED. PLEASE SEE SHEETS A1.02 THROUGH |
| | A1.05 FOR ADDITIONAL DIMENSIONS. LEVELS 6 AND 7 ARE |
| | ENTIRELY VALET PARKING AND UTILIZE FABRICATED STACKERS. |
| | ZONING REVIEW 12/2/22 ??? [SATISFIED] |
| | |
| | 9. HISTORIC PRESERVATION: THE 501 FERN ST. BUILDING IS |
| | HISTORICALLY ELIGIBLE, PER THE REQUIREMENT OF SEC. |
| | 94-131 THE BUILDING SHALL BE INTEGRATED INTO THE |
| | PROJECT AS PART OF THE NEW DEVELOPMENT. IF THE NEW |
| | QUADRILLE PLAZA DR. ROW DOES NOT CONSUME THIS BUILDING, |
| | BOTH HISTORIC PRESERVATION AND PLANNING STAFF REQUEST |
| | THAT THE DESIGN ELEMENTS FROM THE FRONT FACADE OF THE |
| | 501 BUILDING IS PRESERVED, REPLICATED, OR INTEGRATED |
| | INTO THE GROUND-FLOOR DESIGN OF THE PROPOSED 515 |
| | BUILDING AT THIS CORNER. PARTICULARLY THE FLUTED |
| | COLUMN-LIKE ELEMENTS AND THE HORIZONTAL STRIATIONS OF |
| | THE CORNICE AND ENTRY CANOPY. |
| | |
| | RESPONSE: THE BUILDING REFERENCED IS IN THE PROPOSED |
| | 60??? ROW AND THE BUILDING WILL BE REMOVED. |
| | ZONING REVIEW 12/2/22 ??? [PARTIALLY SATISFIED] PER |
| | CONVERSATION WITH PLANNING & HISTORIC PRESERVATION |
| | STAFF, HAS THERE BEEN ANY ALTERATION OR PROPOSED |
| | INCLUSION OF ARCHITECTURAL ELEMENTS OR REFERENCES TO |
| | THE REMOVED ELIGIBLE STRUCTURE? |
| | |
| | 10. PLEASE LABEL AND PROVIDE SIDEWALK DIMENSIONS, AS |
| | WELL AS DIMENSIONS FOR PLANTERS/LANDSCAPE AREAS OR |
| | ELEMENTS WITHIN THE ROW ON BOTH THE GROUND FLOOR AND |
| | SITE PLAN A0.05 AND A0.01; APPEARS TO BE 8-12 FEET |
| | CLEAR, STAFF WOULD LIKE TO VERIFY THAT THE 8 FOOT CLEAR |
| | PATH IS MAINTAINED. CIVIL PLANS PROVIDE THESE |
| | DIMENSIONS. |
| | |
| | RESPONSE: PLEASE SEE SHEETS A0.05 AND A1.01 FOR |
| | ADDITIONAL SIDEWALK AND PLANTER LABELS AND DIMENSIONS |
| | ZONING REVIEW 12/2/22 ??? [SATISFIED] |
| | |
| | 11. SHEET A0.06D FOR THE FA??ADE ARTICULATION |
| | COMPLIANCE MATRIX: WEST, ON THE PROVIDED FENESTRATION |
| | IT IS NOTED THAT FA??ADE E & G ARE MORE THAN 3 FEET |
| | FROM THE LOT LINE; SHOULD THIS READ AS LESS THAN 3 FT.? |
| | |
| | RESPONSE: NOTE IN MATRIX WAS IN ERROR. FACADES E AND H |
| | ARE NON-APPLICABLE AS THEY ARE NON-ACTIVE USE FACADES. |
| | THE BALANCE OF THE WEST FACADES ARE ACTIVE USES AND |
| | COMPLY. PLEASE SEE REVISED MATRIX, SHEET A0.06D. |
| | ZONING REVIEW 12/2/22 ??? [SATISFIED] |
| | |
| | 12. DUE TO THE SIGNIFICANCE IN SCALE FOR THE PROPOSED |
| | DEVELOPMENT PROJECT AND ITS IMPACT ON THE SURROUNDING |
| | ROADWAY NETWORK, STAFF REQUESTS THAT TDM STRATEGIES ARE |
| | DISCUSSED FOR THIS PROJECT. |
| | |
| | RESPONSE: SIMILAR TO 360 ROSEMARY, GIVEN THE EVOLVING |
| | NATURE OF TRANSPORTATION MANAGEMENT STRATEGIES, THE |
| | APPLICANT WILL WORK WITH THE CITY ON A TDM PROGRAM FOR |
| | THE PROJECT THAT WILL BE IN PLACE PRIOR TO THE ISSUANCE |
| | OF A TCO. |
| | ZONING REVIEW 12/2/22 ??? [SATISFIED] TO BE DISCUSSED |
| | FURTHER WITH CITY STAFF AND APPLICANT |
| | |
| | 13. ON THE SHEET A0.06E, PLEASE PROVIDE PROJECTION |
| | DIMENSION ON THE HORIZONTAL FEATURES. |
| | |
| | RESPONSE: PLEASE SEE SHEETS A0.06E, A0.6F, AND A0.6H |
| | FOR ADDED DIMENSIONS AT HORIZONTAL FEATURES. |
| | |
| | ZONING REVIEW 12/2/22 ??? [SATISFIED] |
| | |
| | 14. QUADRILLE PLAZA DR. EXTENSION SHOULD BE |
| | RIGHT-TURN-ONLY AT FERN ST. INTERSECTION, NOT ENOUGH |
| | QUEUING OR STACKING SPACE BEFORE THE TRAIN TRACKS. |
| | |
| | RESPONSE: ACKNOWLEDGED. |
| | |
| | ZONING REVIEW 12/2/22 ??? [SATISFIED] |
| | |
| | 15. PLEASE ILLUSTRATE SITE VISIBILITY TRIANGLES SO THAT |
| | STAFF MAY VERIFY THAT THERE ARE NO OBSTRUCTIONS AT THE |
| | INTERSECTIONS AND DRIVES. |
| | |
| | RESPONSE: SITE VISIBILITY TRIANGLES HAVE BEEN ADDED TO |
| | THE DRAWINGS, AND THE PROPOSED PLANTING HAS BEEN |
| | ADJUSTED, SEE SHEET LP-2. |
| | |
| | ZONING REVIEW 12/2/22 ??? [NOT SATISFIED] SITE |
| | VISIBILITY TRIANGLES NEED TO BE ADJUSTED TO BE FROM THE |
| | INTERSECTION OF THE PROPERTY LINES AND CORNERS. SEE |
| | SEC. 94-305(E.) AND FIGURE X-1. |
| | |
| | VISIBILITY AT INTERSECTIONS. AT ANY ROAD INTERSECTIONS, |
| | VISIBILITY SHALL NOT BE OBSCURED BY THE CONSTRUCTION, |
| | PLACEMENT, OR MAINTENANCE OF A STRUCTURE WALL, SIGN, |
| | FENCE, BERM, PLANT MATERIAL, SHRUBS, OR ANY SIMILAR |
| | ITEM BETWEEN 18 INCHES OR EIGHT FEET IN HEIGHT WITHIN A |
| | TRIANGLE BEGINNING AT THE POINT WHERE PROPERTY LINES |
| | MEET AT THE CORNER, THEN 20 FEET ALONG THE FRONT |
| | PROPERTY LINE, THENCE DIAGONALLY TO A POINT ALONG THE |
| | SIDE PROPERTY LINE 20 FEET FROM THE POINT OF BEGINNING, |
| | AND THENCE TO THE POINT OF BEGINNING. IN THE EVENT THE |
| | CORNER OF AN INTERSECTION IS ROUNDED, THE MEASUREMENT |
| | SHALL BEGIN AT THE POINT THE PROPERTY LINES WOULD MEET |
| | WITHOUT ROUNDING. (SEE FIGURE X-1) |
| | |
| | 16. MINOR NOTE: DRAWINGS ONLY PROVIDE ENTRY TO BIKE |
| | ROOM FROM OUTSIDE PLAZA, IS THIS INTENTIONAL? |
| | |
| | RESPONSE: YES, THIS IS INTENTIONAL, IN ORDER TO ALLOW |
| | ALL BUILDING OCCUPANTS TO PASS THROUGH THE LOBBY |
| | CONTROL AREA. |
| | ZONING REVIEW 12/2/22 ??? [NOT SATISFIED] PLEASE |
| | CONSIDER ALTERNATIVE ENTRY INTO BUILDING FROM BIKE |
| | ROOM, IF THE CONCERN IS SECURITY PLEASE NOTE MANY OF |
| | THE INTERNAL CORRIDORS AND BACK OF HOUSE ROOMS ADJACENT |
| | TO LOADING OPERATION PROVIDE ACCESS TO THE INTERIOR OF |
| | BUILDING. THE BIKE ROOM SHOULD REFLECT A SIMILAR |
| | CONDITION, AS CIRCULATING USERS OUTSIDE OF THE BUILDING |
| | DISCOURAGES BIKE USE. |
| | |
| | 17. PLEASE PROVIDE A DETAILED AND DIMENSIONED SCHEMATIC |
| | FOR THE INTERNAL BIKE ROOM, SHOWING THE PROPOSED RACKS |
| | FROM A3.01 WITH ADEQUATE SPACING/SEPARATION WITHIN THE |
| | ROOM. PLEASE PROVIDE THE SPACING DETAILS FOR THE |
| | OUTSIDE BIKE RACK AS WELL. |
| | |
| | RESPONSE: PLEASE SEE SHEET A3.01 / DETAIL 6 FOR INDOOR |
| | BIKE ROOM LAYOUT. DIMENSIONS FOR THE OUTSIDE BIKE RACKS |
| | HAVE BEEN ADDED, SEE SHEET LH-1. |
| | ZONING REVIEW 12/2/22 ??? [SATISFIED] |
| | |
| | 18. PER SEC. 94-111; A MINIMUM OF ONE SHOWER AND |
| | CHANGING FACILITY SHALL BE PROVIDED OR BE AVAILABLE FOR |
| | ALL TENANTS AND SHALL BE LOCATED WITHIN THE BUILDING, |
| | OR WITHIN 200 FEET OF THE BUILDING ENTRANCE, FOR |
| | DEVELOPMENTS GREATER THAN 50,000 SQUARE FEET IN GROSS |
| | BUILDING AREA. |
| | PLEASE INDICATE ON THE PLANS WHERE THIS SHOWER FACILITY |
| | IS LOCATED. |
| | |
| | RESPONSE: PLEASE SEE SHEET A1.01. THE SHOWER IS |
| | INDICATED JUST WEST OF STAIR 1, ALONG THE CORRIDOR |
| | CONNECTING THE BUILDING LOBBY TO THE MANAGEMENT OFFICES |
| | AND THE LOADING AREA. THE SHOWER IS LOCATED |
| | APPROXIMATELY 110 FEET FROM THE MAIN BUILDING ENTRANCE. |
| | ZONING REVIEW 12/2/22 ??? [NOT SATISFIED] PLEASE |
| | CONSIDER RELOCATING THE SHOWER FACILITY CLOSER TO THE |
| | STORAGE ROOM OF THE BIKES, CIRCULATION OF USERS |
| | DOESN???T SEEM TO MAKE MUCH SENSE, REQUIRES USERS TO GO |
| | AROUND BUILDING AND ON THE OPPOSITE SIDE. PERHAPS WHERE |
| | THE STORAGE ROOM IS LOCATED IS MORE APT FOR SHOWER |
| | FACILITIES. |
| | |
| | 19. SHEET A3.01 PARKING STALL DIMENSIONS NOT COMPLIANT |
| | WITH CITY STANDARD AND STRIPPING DETAIL. STANDARD |
| | SPACES SHOULD BE 8.5FTX18FT AND ADA SPACES ARE |
| | 12FTX18FT WITH 5 ADA AISLE, COMPACT SPACES ARE |
| | TYPICALLY 8FTX16FT. PLEASE NOTE, ONLY 30% OF PARKING |
| | SPACES MAY BE DESIGNATED AS COMPACT SPACES AND SHALL BE |
| | INDICATED COMPACT SPACES WILL REQUIRE SEPARATE SIGNAGE |
| | DESIGNATING THESE SPACES AS COMPACT. |
| | |
| | RESPONSE: PARKING STALL DIMENSIONS AND STRIPING DETAILS |
| | AS SHOWN ON SHEET A3.01 ARE CONSISTENT WITH THE |
| | REQUIREMENTS OF SECTION 94-485 OF THE WEST PALM BEACH |
| | ZONING CODE, INCLUDING FIGURE XV-2 AND THE STALL |
| | PAINTING DETAIL. WE HAVE SPLIT THE STANDARD SPACE AND |
| | ACCESSIBLE SPACE DETAILS INTO TWO SEPARATE DETAILS FOR |
| | FURTHER CLARITY. |
| | |
| | 21% OF PARKING SPACES SHOWN ARE INDICATED AS COMPACT |
| | SPACES AND WILL BE SIGNED TO SO INDICATE. PLEASE SEE |
| | SHEETS A1.02 THROUGH A1.07. |
| | |
| | ZONING REVIEW 12/2/22 ??? [SATISFIED] |
| | |
| | 20. SHEET A1.06 & A1.07 SHOWS WHAT APPEARS TO BE TANDEM |
| | SPACES, PLEASE NOTE PER SEC. 94-111 (E.): FOR |
| | COMMERCIAL USES, TANDEM PARKING SPACES SHALL BE COUNTED |
| | AS ONE SPACE UNLESS THERE IS A VALET ATTENDANT IN |
| | CHARGE OF ALL OPERATING HOURS, AND SUCH REQUIREMENT IS |
| | ESTABLISHED THROUGH A RESTRICTIVE COVENANT. ALL |
| | RESTRICTIVE COVENANTS AND OTHER DOCUMENTS REQUIRED TO |
| | BE RECORDED SHALL BE ON CITY APPROVED FORMS, AND |
| | RECORDED IN PUBLIC RECORDS. |
| | |
| | RESPONSE: ACKNOWLEDGED. ALL TANDEM SPACES WILL BE |
| | SERVED BY A VALET ATTENDANT DURING OPERATING HOURS. THE |
| | PROPERTY OWNER WILL EXECUTE A RESTRICTIVE COVENANT, AS |
| | REQUIRED. |
| | ZONING REVIEW 12/2/22 ??? [SATISFIED] CONDITION OF SITE |
| | PLAN APPROVAL. |
| | |
| | ADDITIONALLY DUE TO THE INCLUSION OF STACKERS, PER SEC. |
| | 94-111(K.): MECHANICAL AND AUTOMATED PARKING. PARKING |
| | STRUCTURES WITH MECHANICAL PARKING SHALL PROVIDE A |
| | COMMERCIAL ATTENDANT DURING THE OPERATIONS HOURS, AND |
| | SUCH OPERATION IS ESTABLISHED THROUGH A RESTRICTIVE |
| | COVENANT RECORDED IN THE PUBLIC RECORDS. ALL |
| | RESTRICTIVE COVENANTS AND OTHER DOCUMENTS REQUIRED TO |
| | BE RECORDED SHALL BE ON CITY APPROVED FORMS, AND |
| | RECORDED IN THE PUBLIC RECORDS. |
| | |
| | RESPONSE: ACKNOWLEDGED. ALL STACKER SPACES WILL BE |
| | SERVED BY A VALET ATTENDANT DURING OPERATING HOURS. THE |
| | PROPERTY OWNER WILL EXECUTE A RESTRICTIVE COVENANT, AS |
| | REQUIRED. |
| | ZONING REVIEW 12/2/22 ??? [SATISFIED] CONDITION OF SITE |
| | PLAN APPROVAL. |
| | |
| | A VALET OR OPERATION ATTENDANT WILL BE REQUIRED FOR |
| | STACKERS, AS SUCH THE TANDEM SPACE IF SERVICED BY THE |
| | VALET OPERATIONS MAY COUNT AS 2 SPACES. PLEASE PROVIDE |
| | DETAILS OF THE STACKERS. |
| | |
| | RESPONSE: PLEASE SEE DETAILS 7 & 9 / SHEET A3.01 FOR |
| | THE STACKER DETAIL. |
| | ZONING REVIEW 12/2/22 ??? [SATISFIED] |
| | |
| | 21. PLEASE CLARIFY MIDDLE OF PARKING STRUCTURE ON SHEET |
| | A1.05, ELECTRIC SPACES APPEAR TO OVERLAP COMPACT |
| | SPACES, AND CONFLICT WITH THE PARKING RAMP. |
| | |
| | RESPONSE: THE AREA IN QUESTION ON SHEET A1.05 IS |
| | SHOWING LEVEL 4.5, BELOW, AND THUS SPACES APPEAR TO BE |
| | OVERLAPPING. WE HAVE MORE CLEARLY INDICATED A GUARD |
| | WALL AT THE EDGE OF SLAB OF LEVEL 5 ON A1.05, REVISED. |
| | |
| | ZONING REVIEW 12/2/22 ??? [SATISFIED] |
| | |
| | 22. SHEET A1.01 SHOWS A CANOPY ON THE FERN ST. SIDE, |
| | PLEASE PROVIDE DETAILS THAT THE CANOPY IS IN COMPLIANCE |
| | WITH THE PROJECTION STANDARDS OF SEC. 94-109 TABLE |
| | IV-5. REQUIRES 10FT. VERTICAL CLEARANCE, MAXIMUM |
| | ENCROACHMENT IN ROW OF 12FT AND MAXIMUM PROJECTION OF |
| | 20FT. |
| | |
| | RESPONSE: PLEASE SEE DETAILS 4 AND 5 ON SHEET A0.06E, |
| | WITH ADDITIONAL DIMENSIONAL INFORMATION. |
| | |
| | ZONING REVIEW 12/2/22 ??? [SATISFIED] |
| | |
| | |
| | ZONING REVIEW 12/12/22 ??? NEW COMMENTS/VARIANCE LIST: |
| | |
| | 1. ALONG FERN ST. FRONTAGE, STREET TREES NEED TO BE |
| | LOCATED ADJACENT TO THE CURB, MOVE TREES INTO PROPOSED |
| | LANDSCAPE BEDS ON EITHER SIDE OF THE PROPOSED DROP-OFF |
| | SPACE. IF REQUIREMENT CANNOT BE ACCOMODATED MAY BE |
| | SUBJECT TO VARIANCE. |
| | |
| | 2. ALONG FERN ST. FRONTAGE, STREET TREES NEED TO MEET |
| | THE 30 FT. ON CENTER MEASUREMENT, PALMS DO NOT COUNT |
| | TOWARD TREE COUNT, NEED AT LEAST 10 ON FERN FRONTAGE. |
| | THE TREES WITHIN TREEGRATES ADJACENT TO THE DROP-OFF |
| | MUST MEET 30 FT. SPACING TOO. IF REQUIREMENT CANNOT BE |
| | ACCOMODATED MAY BE SUBJECT TO VARIANCE. |
| | |
| | VARIANCES: |
| | 1. CONDITIONAL SETBACK OF 27??? FROM BACK OF CURB ALONG |
| | EVERNIA FOR LEVELS 5+ OF PARKING. REQUESTING A 12??? |
| | REDUCTION ON LEVEL 6 & LEVEL 7. |
| | 2. VARIANCE FROM SECTION 94-132(E.)(3.)(C.) TO COUNT |
| | THE PORTION OF THE SETBACK/LAND DEDICATION AREA WITHIN |
| | BUILDING REQUIREMENTS. |
| | 3. VARIANCE FROM PARKING REQUIREMENTS (TABLE IV-9) FOR |
| | OFFICE USES. DEFICIENT 180 SPACES FOR OFFICE USE. MIN. |
| | REQ. 946 PROVIDING 766. (19% REDUCTION) |
| | |
| | |
| |