Date Text
2023-01-13 19:11:451) PARTIALLY SATISFIED. PROVIDE COUNTY TPS LETTER, ONCE
 RECEIVED
 2) SATISFIED. PROVIDE A PARKING TABLE SHOWCASING THE
 NUMBER OF REQUIRED AND PROVIDED PARKING SPACES,
 INCLUSIVE OF ADA AND BICYCLE ONES. PROVIDE DOCUMENT
 NAME AND SHEET NUMBER CONTAINING SUCH INFORMATION
 3) SATISFIED. PROVIDE AN ACCESSIBILITY ROUTE FOR EACH
 ADA STALL
 4) PARTIALLY SATISFIED. MINIMUM DRIVE AISLE IS 24-FEET
 FOR EITHER 90-DEGREE PARKING ANGLE OR TWO-WAY DIRECTION
 MOVEMENT. SOME OF THE PROPOSED DRIVE AISLES ARE
 20-FEET, PLEASE CORRECT. THE 20-FEET WIDTH COULD BE
 ACCEPTABLE IF UTILIZED BY DEALERSHIP PERSONNEL. PLEASE
 INSTALL SIGNAGE AND/OR PAVEMENT MARKING TO LIMIT PUBLIC
 ACCESS TO SUCH DRIVE AISLES.
 5) SATISFIED. PROVIDE ENGINEERING REFERENCE AND SPECS
 SHEETS FOR THE ADA PARKING STALLS, VERIFY COMPLIANCE
 ACCORDINGLY. PROVIDE DOCUMENT NAME AND SHEET NUMBER
 CONTAINING SUCH INFORMATION
 6) NOT SATISFIED. PROVIDE AUTOTURN ANALYSIS FOR GARBAGE
 TRUCK AND/OR SERVICE VEHICLES DRIVING IN AND OUT OF THE
 PROPOSED DEVELOPMENT WITH VEHICLE DYNAMIC ENVELOPES AND
 WHEEL PATHS CLEARLY DISTINCT AND DEFINED IN DIFFERENT
 COLORS. PROVIDE DOCUMENT NAME AND SHEET NUMBER
 CONTAINING SUCH ANALYSIS. LATEST SUBMISSION IS NOT
 SUFFICIENT AND NOT SHOWING THE
 7) PROVIDE A VALET OPERATIONAL ANALYSIS. PLEASE PROVIDE
 A SHORT NARRATIVE AND SHOWCASE PICK-UP/DROP-OFF
 LOCATION(S), VALET PARKING STALLS, AND TYPICAL VALET
 VEHICLE CIRCULATION TO/FROM SUCH STALLS
  
 VALERIO ORICCHIO
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]
  
  
  