| Date |
Text |
| 2023-01-10 16:46:31 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER |
| | 561-822-1462 |
| | PROJECT: 2235 OKEECHOBEE Z22090007 |
| | JANUARY 6, 2023 |
| | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND |
| | PROVIDE THE FOLLOWING COMMENTS: |
| | |
| | 1. PARTIALLY SATISFIED. PROVIDE A TREE DISPOSITION AND |
| | MITIGATION LIST. SECTION 94-448 (D)(3) REQUIRES NATIVE |
| | TREES IN GOOD CONDITION TO BE PRESERVED ON SITE OR |
| | RELOCATED. ANSI A 300 (PART 5) STANDARDS SPECIFY |
| | EXAMPLES OF SUITABILITY RATINGS OF GOOD, MODERATE, OR |
| | POOR FOR RELOCATION. PROVIDE AN ARBORIST REPORT SHOWING |
| | CONDITION AND RELOCATION POTENTIAL FOR ANY NATIVE TREES |
| | OR PALMS TREES AND PALMS PROPOSED TO BE REMOVED. |
| | APPLICANT HAS INDICATED A TREE DISPOSITION LIST WILL BE |
| | PROVIDED WITH THE RESUBMITTAL. |
| | MAKE THE FOLLOWING CORRECTIONS TO THE TREE DISPOSITION |
| | CHART: |
| | ??? TREE #6 PLUMERIA IS CATEGORY 2, SO MITIGATION DUE |
| | IS 150 SQ FT. |
| | ??? TREE #56 QUEEN PALM IS CATEGORY 4, SO MITIGATION |
| | DUE IS 50 SQ FT. |
| | ??? WITH THE ABOVE CHANGES, REVISED TOTAL CANOPY |
| | MITIGATION SHOULD BE 1241 SQ FT. |
| | |
| | 2. PARTIALLY SATISFIED. THE SITE PLAN AND LANDSCAPE |
| | PLAN DO NOT MATCH THE SURVEY ALONG THE EAST PROPERTY |
| | LINE. THE PERVIOUS AREA IS OUTSIDE THE FENCE ON THE |
| | ADJACENT PROPERTY. CORRECT THE PLANS TO MATCH THE |
| | SURVEY. IF PERVIOUS AREA IS BEING ADDED, INDICATE THIS |
| | ON THE SITE PLAN AND PROVIDE THE REQUIRED LANDSCAPE |
| | BUFFER ALONG THE EAST PROPERTY LINE. |
| | THE VEHICLE OVERHANG IS OVERLAPPING 2 FEET OF THE 5 |
| | FOOT BUFFER, ADJUST THE PARKING SPACE TO THE WEST TO |
| | ELIMINATE ENCROACHMENT INTO THE LANDSCAPE BUFFER. |
| | |
| | |
| | 3. PARTIALLY SATISFIED. PER SECTION 94-443(C)(3)A. AND |
| | B., TERMINAL LANDSCAPE ISLANDS AND INTERIOR ISLANDS |
| | MUST HAVE AT LEAST 8 FEET WIDE LANDSCAPE AREA AND RUN |
| | THE FULL LENGTH OF THE ADJACENT PARKING SPACE. EACH |
| | AREA SHALL HAVE AT LEAST ONE SHADE OR FLOWERING TREE |
| | PER ROW OF PARKING AND AN INTERIOR ISLAND MUST BE |
| | PROVIDED SO THERE ARE NO MORE THAN 10 SPACES IN A ROW. |
| | PROVIDE THE REQUIRED LANDSCAPE ISLANDS FOR ALL REQUIRED |
| | PARKING. THERE ARE TERMINAL ISLANDS MISSING IN SEVERAL |
| | LOCATIONS. |
| | THE ROW OF PARKING DIRECTLY SOUTH OF THE NEW BUILDING |
| | IS LACKING A TERMINAL ISLAND ADJACENT TO THE BUILDING |
| | ON THE WEST END OF THE ROW. A TERMINAL ISLAND CURRENTLY |
| | EXISTS IN THIS LOCATION. THE INTERIOR LANDSCAPE ISLAND |
| | ADDED AT THE SOUTHWEST CORNER OF THE PARKING ROW |
| | ADJACENT TO OKEECHOBEE NEEDS TO BE LOCATED ON THE EAST |
| | SIDE OF THE ADA SPACES SO THERE ARE NO MORE THAN 10 |
| | SPACES IN A ROW. |
| | |
| | 4. PARTIALLY SATISFIED. SECTION 94-443(C)(3) REQUIRES |
| | THAT A MINIMUM OF 75 PERCENT OF ALL TREES THAT ARE |
| | REQUIRED TO BE PLANTED WITHIN THE INTERIOR OF AN OFF |
| | STREET PARKING AREA SHALL BE CATEGORY 1 SHADE TREES. |
| | HIGH RISE OAK DOES NOT MEET THE INTENT OF PROVIDING |
| | TREE CANOPY FOR THE PARKING AREAS SO CANNOT BE COUNTED. |
| | MAKE ALL ADJUSTMENTS FROM OTHER COMMENTS AND |
| | RECALCULATE THIS. |
| | |
| | |
| | 5. PARTIALLY SATISFIED. PROVIDE AN EXHIBIT SHOWING THE |
| | PARKING AREA VEHICULAR USE AREA SURFACE CALCULATIONS, |
| | PARKING SPACE AREAS AND LANDSCAPE AREAS PROVIDED TO |
| | DEMONSTRATE COMPLIANCE WITH SECTIONS 94-443 (C)(3) AND |
| | (4). PROVIDE THE CORRECTED CALCULATIONS IN THE |
| | LANDSCAPE REQUIREMENT CHART. REFER TO FIGURE XIV-1. |
| | SHOW THE ACTUAL PROVIDED INTERIOR LANDSCAPE SQUARE |
| | FOOTAGE. BUFFERS AND NON-INTERIOR LANDSCAPING CANNOT BE |
| | COUNTED. |
| | ADDRESS THE MISSING TERMINAL ISLANDS FROM COMMENT #3 |
| | AND ADJUST ON THE PLAN. |
| | |
| | |
| | 6. SATISFIED. STORMWATER LINE AND EXFILTRATION PROPOSED |
| | ALONG THE EAST SIDE OF THE PARKING AREA CONFLICT WITH |
| | THE REQUIRED LANDSCAPE TERMINAL ISLAND AND TREE |
| | REQUIREMENT. ADJUST THE DRAINAGE LINE TO AVOID THE |
| | REQUIRED LANDSCAPING. |
| | |
| | 7. PARTIALLY SATISFIED. PROVIDE A DIAGRAM OF THE 30% |
| | REQUIRED AND PROVIDED LINEAR LANDSCAPE FOR AROUND EACH |
| | BUILDING INCLUDING THE CAR WASH BUILDING AS INDICATED |
| | IN THE CODE REQUIREMENT CHART. THE CODE REQUIRES TREES |
| | SHRUBS OR HEDGES. |
| | THE CALCULATIONS PROVIDED DO NOT CORRECTLY SHOW THE |
| | PERCENTAGE FOR EACH BUILDING. PROVIDE A DIAGRAM SHOWING |
| | COMPLIANCE. |
| | |
| | |
| | 8. SATISFIED. IMPERVIOUS/LANDSCAPE AREA IS NOT WITHIN |
| | THE REQUIREMENT OF 15% OF THE SITE. STAFF SUGGESTS |
| | ADDING LANDSCAPE AREA TO MEET THE 15% REQUIRED. THERE |
| | ARE MANY OPPORTUNITIES THAT CAN BE IMPROVED IN THE |
| | STORAGE AREAS |
| | |
| | 9. SATISFIED. UTILITY LINES ARE SHOWN, BUT THERE ARE |
| | MULTIPLE CONFLICTS WITH THE LOCATIONS OF LINES AND |
| | LANDSCAPING. ADJUST LOCATIONS OF UTILITIES TO AVOID |
| | LANDSCAPE AREAS. |
| | |
| | 10. SATISFIED. MINIMUM NUMBER OF REQUIRED TREES IS NOT |
| | MET FOR THE SITE. ADD TREES TO MEET THE MINIMUM |
| | REQUIRED. UP TO 35% OF THE REQUIRED TREES CAN BE PALM |
| | SUBSTITUTIONS. |
| | |
| | 11. SATISFIED. PROVIDE THE 50 REQUIRED FLORIDA FRIENDLY |
| | POINTS BASED ON THE FINAL PLANT LIST PER SECTION |
| | 94-443(G) AFTER REVISIONS TO PLANS ARE MADE. |
| | |
| | CONDITIONS OF APPROVAL |
| | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON |
| | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE |
| | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT |
| | SERVICES DEPARTMENT, PLANNING DIVISION. |
| | |
| |
Print |