| Date |
Text |
| 2022-09-06 15:29:29 | 9/6/22 ? FAILED |
| | |
| | |
| | PLEASE NOTE THE FOLLOWING PROCESS COMMENTS WHEN |
| | RESUBMITTING: |
| | A. WRITTEN RESPONSES TO COMMENTS MADE BY ALL |
| | DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION. |
| | B. PROVIDE AN ELECTRONIC COPY OF ALL PLANS AND REQUIRED |
| | MATERIALS AND 2 SETS OF FOLDED PHYSICAL PLANS, ALONG |
| | WITH ONE (1) REDUCED COPY (11 IN X 17 IN). |
| | C. PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO |
| | ADDITIONAL COMMENTS. |
| | D. IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE |
| | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE |
| | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL |
| | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. |
| | E. PLEASE NOTE THAT YOU ARE PERMITTED ONE (1) |
| | RESUBMITTAL AT NO ADDITIONAL COST. A RESUBMITTAL FEE OF |
| | 20% OF THE ORIGINAL APPLICATION FEE WILL BE ASSESSED |
| | AFTER THE FIRST RESUBMITTAL. |
| | |
| | REQUIRED MATERIALS MUST BE PROVIDED: |
| | F. PLEASE PROVIDE CONFIRMATION LETTERS FROM PUBLIC |
| | UTILITIES (AT&T TELECOMMUNICATION, FLORIDA PUBLIC |
| | UTILITIES, AND COMCAST CABLE COMMUNICATIONS) CONFIRMING |
| | THAT THE PROPOSED PROJECT DOES NOT ENCROACH INTO THEIR |
| | EASEMENTS OR OTHERWISE INTERFERE WITH THE PROVISIONS OF |
| | THEIR SERVICES. |
| | G. PLEASE PROVIDE EVIDENCE OF THE UNIFIED CONTROL OF |
| | THE ENTIRE AREA. |
| | H. PLEASE PROVIDE THE AGREEMENTS, PROVISIONS OR |
| | COVENANTS WHICH GOVERN THE USE, MAINTENANCE AND |
| | CONTINUED PROTECTION OF THE PD AND ANY OF ITS COMMON |
| | AREAS OR FACILITIES. |
| | I. PLEASE PROVIDE REVISED PLANS ADDRESSING THE REVIEW |
| | COMMENTS BELOW. |
| | J. PLEASE PROVIDE/INDICATE/DEMONSTRATE CONSISTENT |
| | INFORMATION ON ALL THE DIFFERENT PLANS AND REQUIRED |
| | MATERIALS WITHIN THE APPLICATION PACKET RESUBMITTAL. |
| | K. PLEASE PROVIDE COMPLETED PUBLIC NOTICE MAILER |
| | AFFIDAVITS WHEN MAILERS HAVE BEEN SENT OUT. |
| | L. PLEASE PROVIDE COMPLETED SIGN POSTING AFFIDAVITS |
| | WHEN SIGNS HAVE BEEN PUT UP. |
| | |
| | REVIEW COMMENTS MUST BE ADDRESSED: |
| | 1. IN ACCORDANCE WITH THE CITY?S ZONING AND LAND |
| | DEVELOPMENT REGULATIONS (ZLDR) SUBSECTION |
| | 94-207(B)(9)(A)(1), PLEASE IDENTIFY/INDICATE THE NAME |
| | OF THE DEVELOPER ON THE ?COVER? SHEET NUMBER A-0 AND/OR |
| | ?SITE PLAN? SHEET NUMBER A-1. |
| | 2. THE PROPOSAL DEMONSTRATED IS NOT IN COMPLIANCE WITH |
| | THE (VISIBILITY TRIANGLE AT INTERSECTIONS REQUIREMENT) |
| | ZLDR SUBSECTION 94-207(B)(6), THEREFORE, PLEASE REVISE |
| | THE DIFFERENT PLANS, ELEVATIONS, AND SECTION, |
| | ACCORDINGLY. |
| | 3. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE EXISTING |
| | AND PROPOSED EASEMENTS ON THE DIFFERENT PLANS. |
| | 4. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE EXISTING |
| | AND PROPOSED FIRE HYDRANTS (OR OPERATIONAL EQUIVALENTS) |
| | WITHIN 250 FEET OF THE PROPOSED STRUCTURE(S) ON THE |
| | ?SITE PLAN? SHEET NUMBER A-1. |
| | 5. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE LOCATION OF |
| | ANY SPECIAL UTILITY STRUCTURES SUCH AS VALVES, METERS, |
| | BACKFLOW CONNECTIONS, PUMP STATIONS, TRANSFORMERS, AND |
| | ALL ABOVE GROUND APPURTENANCES ON THE ?SITE PLAN? SHEET |
| | NUMBER A-1. |
| | 6. THE PROPOSED LOADING SPACES ARE NOT IN COMPLIANCE |
| | WITH THE MINIMUM LOADING SPACE DIMENSIONAL REQUIREMENTS |
| | OF THE ZLDR SUBSECTION 94-485(P), THEREFORE PLEASE |
| | REVISE THE DIFFERENT PLANS, ACCORDINGLY. |
| | 7. PLEASE FURTHER EXPLAIN/CLARIFY/CONFIRM WHETHER THE |
| | PROPOSED LOADING SPACES ARE FOR THE PROPOSED |
| | SELF-STORAGE USE OR FOR ALL THE PROPOSED USES. |
| | 8. IN ACCORDANCE WITH THE ZLDR SUBSECTION 94-485(Q), |
| | PLEASE IDENTIFY/INDICATE THE REQUIRED AND PROPOSED |
| | NUMBER OF BICYCLE PARKING SPACES IN THE ?PARKING? TABLE |
| | ON THE ?SITE PLAN? SHEET NUMBER A-1. |
| | 9. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE EXISTING |
| | BIKE LANE (TO REMAIN) ALONG LA KIRKSEY/15TH STREET ON |
| | THE ?BOUNDARY SURVEY? AND ?SITE PLAN? SHEET NUMBER A-1. |
| | 10. IN ACCORDANCE WITH THE ZLDR SUBSECTION |
| | 94-207(B)(9)(A)(7), PLEASE |
| | IDENTIFY/INDICATE/DEMONSTRATE THE LOCATION OF PROPOSED |
| | MASS TRANSIT FACILITIES ON THE ?SITE PLAN? SHEET NUMBER |
| | A-1. |
| | 11. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE CURB |
| | CUTS/CONCRETE DRIVE ACCESSES REMOVED ALONG DIXIE |
| | HIGHWAY ON THE DIFFERENT PLANS, ACCORDINGLY, SIMILAR TO |
| | THE INFORMATION DISPLAYED ON THE ?SITE PLAN? SHEET |
| | NUMBER C-02, ?DEMOLITION PLAN? SHEET NUMBER C-03, AND |
| | ?PAVING, GRADING, AND DRAINAGE PLANS? SHEET NUMBER |
| | C-04. |
| | 12. PLEASE DEMONSTRATE HOW THE CITY?S SANITATION |
| | SERVICE TRUCKS WILL ACCESS/COLLECT THE TRASH FROM THE |
| | PROPOSED TRASH AREA TO THE SOUTH ON THE ?AUTOTURN |
| | EXHIBIT? SHEET NUMBER C-07. |
| | 13. IN ACCORDANCE WITH THE ZLDR SUBSECTION 94-443, |
| | PLEASE REVISE THE DIFFERENT PLANS AND ELEVATIONS, |
| | ACCORDINGLY, TO IDENTIFY/INDICATE/DEMONSTRATE THE |
| | REQUIRED PROTECTIVE SCREEN WALL ALONG THE WEST PROPERTY |
| | LINE ADJACENT TO THE RESIDENTIAL PROPERTY/RESIDENTIAL |
| | ZONING DISTRICT. |
| | 14. IT HAS BEEN IDENTIFIED THAT THERE ARE |
| | INCONSISTENCIES BETWEEN THE PLANS AND ELEVATIONS |
| | REGARDING THE PROPOSED FIVE-FOOT-HIGH SECURITY/ALUMINUM |
| | FENCE, THEREFORE PLEASE REVISE, ACCORDINGLY. |
| | 15. PLEASE PROVIDE AN |
| | ILLUMINATION/LIGHTING/PHOTOMETRICS PLAN DEMONSTRATING |
| | COMPLIANCE WITH THE ZLDR SUBSECTION 94-207(D)(8). |
| | 16. IN ACCORDANCE WITH THE ZLDR SUBSECTION 94-409, |
| | PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE PROPOSED |
| | BUILDING FA?ADE SIZE, PERCENT SIGNAGE PERMITTED, AND |
| | PERMITTED SIGN SIZE FOR THE PROPOSED WALL MOUNTED SIGNS |
| | ON THE ?COLOR ELEVATIONS? SHEET NUMBERS A-3 TO A-4. |
| | 17. THE PROPOSED ?WEST ELEVATION? WALL MOUNTED SIGN IS |
| | NOT IN COMPLIANCE WITH THE ZLDR SUBSECTION |
| | 94-402(B)(2)(7), THEREFORE PLEASE REVISE THE ?COLOR |
| | ELEVATION? SHEET NUMBER A-4, ACCORDINGLY. |
| | 18. PLEASE PROVIDE THE STANDARD CITY DETAILS OF |
| | VEHICLE/BICYCLE PARKING (STANDARD, COMPACT, ADA), |
| | LOADING, ADA RAMPS, DRIVEWAYS, DUMPSTERS AND SIGNS. |
| | 19. PLEASE UPDATE THE ?SITE DATA? ON THE ?SITE PLAN? |
| | SHEET NUMBER A-1 TO IDENTIFY/INDICATE THE CORRESPONDING |
| | DATA FOR THE ?ALLOWED? INFORMATION WITHIN THE EXISTING |
| | MF14 AND GC ZONING DISTRICTS. |
| | 20. PLEASE UPDATE THE ?SITE DATA? ON THE ?SITE PLAN? |
| | SHEET NUMBER A-1 TO IDENTIFY/INDICATE THE MAXIMUM AND |
| | PROPOSED LOT COVERAGE BY BUILDINGS AND IMPERMEABLE |
| | SURFACE ACCORDING TO THE ZLDR SECTIONS 94-241 AND |
| | 94-243. |
| | 21. PLEASE CORRECT THE ?SITE DATA? ON THE ?SITE PLAN? |
| | SHEET NUMBER A-1 TO IDENTIFY/INDICATE THE MAXIMUM |
| | BUILDING HEIGHTS (?ALLOWED?) INFORMATION ACCORDING TO |
| | THE ZLDR SUBSECTIONS 94-241 AND 94-243 FOR THE EXISTING |
| | MF14 AND GC ZONING DISTRICTS AND ADD THE PROPOSED |
| | HEIGHT ?TO THE TOP OF THE PARAPET? INFORMATION TO |
| | REFLECT THE SAME INFORMATION DEMONSTRATED IN THE |
| | ELEVATIONS. |
| | 22. PLEASE CORRECT THE ?SITE DATA? ON THE ?SITE PLAN? |
| | SHEET NUMBER A-1 TO IDENTIFY/INDICATE THE PROPOSED |
| | ?FRONT (EAST SIDE)? SETBACK TO REFLECT THE SAME |
| | INFORMATION DEMONSTRATED IN THE GRAPHIC/PLAN. |
| | 23. PLEASE CORRECT THE ?PARKING? TABLE ON THE ?SITE |
| | PLAN? SHEET NUMBER A-1 TO IDENTIFY/INDICATE THE |
| | PROPOSED NUMBER OF PARKING SPACES IN WHOLE NUMBERS |
| | ACCORDING TO THE ZLDR SUBSECTION 94-485(H); TO |
| | IDENTIFY/INDICATE CORRECT INFORMATION FOR THE MINIMUM |
| | NUMBER OF REQUIRED ?STORAGE OFFICE? PARKING SPACES |
| | ACCORDING TO THE ZLDR SECTION 94-486; TO |
| | IDENTIFY/INDICATE THE CORRECT INFORMATION FOR THE TOTAL |
| | MINIMUM NUMBER OF REQUIRED PARKING SPACES; AND TO |
| | IDENTIFY/INDICATE THE MINIMUM REQUIRED NUMBER OF ?H.C. |
| | (INCLUSIVE)? PARKING SPACES ACCORDING TO THE ZLDR |
| | SUBSECTION 94-485(O). |
| | 24. PLEASE CORRECT THE ?LOADING? TABLE ON THE ?SITE |
| | PLAN? SHEET NUMBER A-1 TO INDICATE THE MINIMUM LOADING |
| | SPACE DIMENSIONAL REQUIREMENTS ACCORDING TO THE ZLDR |
| | SUBSECTION 94-485(P). |
| | 25. IT HAS BEEN IDENTIFIED THAT THERE ARE |
| | INCONSISTENCIES BETWEEN THE ?SITEPLAN? SHEET NUMBER |
| | A-1, ?SITE PLAN? SHEET NUMBER C-02, AND ?LANDSCAPE |
| | PLAN? SHEET NUMBER L-2.0 REGARDING THE SITE DATA |
| | INFORMATION, THEREFORE PLEASE REVISE, ACCORDINGLY. |
| | |
| | |
| | KEVIE DEFRANC |
| | PLANNER - PLANNING DIVISION |
| | [email protected] |
| | 561-822-1449 |
| | |
| |