Plan Review Notes
Plan Review Notes For Project Z22080024
Project Number Z22080024
Review Stop PU-CS
Sequence Number 1
Notes
Date Text
2022-09-06 16:19:05PLEASE PROVIDE WRITTEN RESPONSES TO THE FOLLOWING:
 -SOUTHWESTERN PROPOSED DRIVEWAY FLARE IS EXTENDING PAST
 PROPERTY LINE.
 -SHOW AND LABEL 12 FOOT D.E. RUNNING THROUGH PROPERTY
 ON CIVIL PLANS AS SHOWN ON SURVEY.
 -40 FOOT CANAL EASEMENT IS NOT SHOWING ON CIVIL PLANS
 AS SHOWN ON SURVEY. PLEASE UPDATE.
 -SURVEY NOTE NUMBER 5 SAYS THAT THERE MAY BE ADDITIONAL
 EASEMENTS OR RESTRICTIONS NOT SHOWN ON SURVEY.
 -ADD DEMO PLAN SHEET TO ENGINEERING PLAN SET IF THERE
 WILL BE DEMOLITION.
 -SHOW AND LABEL EXISTING AND PROPOSED RIGHT OF WAY
 SIDEWALK.
 -WILL THE NORTHERN SWING GATE HIT THE DUMPSTER
 STRUCTURE WHEN OPENS? ALSO WILL THAT SWING GATE HIT
 VEHICLES TRAVELING NORTH PAST IT?
 -WILL MARQUEE SIGN REMAIN, OR IS REPLACEMENT PROPOSED?
 ALSO, PLEASE SHOW AND LABEL IT ON ENGINEERING PLANS.
 -SHOW AND LABEL ALL UTILITY POLES AND LIGHT POLES NEAR
 PROPERTY AND WHAT IS HAPPENING TO THEM.
 -HISTORIC PICTURES SHOW EXISTING FENCES AT SOUTH AND
 EAST SIDES OF PROPERTY. WHO OWNS THOSE FENCES AND ARE
 THE PROPOSED FENCES ADDITIONS OR REPLACEMENTS?
 -PROPOSED SOUTHWESTERN DRIVEWAY LOOKS TO CONFLICT WITH
 EXISTING STORM STRUCTURE.
 -UTILITY BILLING SYSTEM IS SHOWING EXISTING FIRELINE
 WATER SERVICE FOR THE ADDRESS. VERIFY IF THAT IS
 CORRECT AND IF SO, SHOW AND LABEL ON PLANS.
 -VERIFY IF PROPOSED PRIVATE FIRE SYSTEM WILL HAVE ANY
 AUXILIARY WATER SUPPLIES SUCH AS WELLS CONNECTED TO IT.
 -EXISTING DOMESTIC METER SIZE IS 1.5 INCH PER UTILITY
 BILLING SYSTEM.
 -ADD WATER AND SEWER DEMAND CALCULATIONS TO WATER PLAN.
 -SHOW AND LABEL EXISTING SEWER LATERAL AND WHAT IS
 HAPPENING TO IT.
 -CALLOUT HORIZONTAL CLEARANCE DISTANCE BETWEEN SEWER
 LATERAL AND POTABLE PLUMBING.
 -ARCHITECTURAL PLAN SHOWS ADDITIONAL DUMPSTER NOT SHOWN
 ON ENGINEERING PLAN.
 -ADD ENGINEERING PLAN SHEET SHOWING RV PARKING BEFORE
 PHASE II IS COMPLETE.
 -ON LP2, SOME OF THE RV PARKING SPOTS LOOK PROBLEMATIC
 WHERE THE RV?S MAY HIT THE SWING GATES COMING OUT OF
 THE PARKING SPOTS.
 -WILL THE IRRIGATION RUN OFF OF DOMESTIC WATER SERVICE,
 OR IS A SEPARATE METERED IRRIGATION WATER SERVICE
 NEEDED?
 RESPECTFULLY,
 MARK HURLEY [email protected]
  Print


Account Summary | Usage Policy | Privacy Policy