Plan Review Notes
Plan Review Notes For Project Z22080016
Project Number Z22080016
Review Stop TRAFFIC
Sequence Number 2
Notes
Date Text
2023-06-20 00:51:26TRAFFIC COMMENTS
 1) NOT SATISFIED. GIVEN THE CHANGE IN SQUARE FOOTAGE,
 CIRCULATION AND DRIVEWAY CONFIGURATION. PROVIDE AN
 UPDATED TRAFFIC ANALYSIS. LATEST RESUBMISSION DID NOT
 PROVIDE A REVISED OPERATIONAL MANAGEMENT PLAN
 2) PLEASE PROVIDE FURTHER NARRATIVE AND ELABORATION
 PERTAINING THE EXPECTED QUEUES WITHIN THE PROPOSED
 DEVELOPMENT AS WELL AS THE SURROUNDING ROADWAY NETWORK.
 THE LATTER IS SIGNIFICANTLY IMPACTED DURING PICK-UP
 OPERATIONS, DUE TO PARENTAL VEHICLES ARRIVING AHEAD OF
 TIME CAUSING QUEUE SPILLBACKS AND TRAVEL LANES BLOCKAGE
 ON N FLAGLER DRIVE
 3) THE CONCLUSION IN THE REPORT IS BASED ON A TRIVIAL
 EVALUATION, INSTEAD OF TRAFFIC ENGINEERING PRINCIPLES
 AND METHODOLOGIES. THUS, PLEASE PROVIDE A COMPREHENSIVE
 QUEUE ANALYSIS, INCLUSIVE OF PROPERLY CALCULATED
 DISCHARGE RATES
  
 SITE COMMENTS
 4) PARTIALLY SATISFIED. PROVIDE A CLEAN TRANSPORTATION
 SPECIFIC SITE PLAN FOR THE GROUND FLOOR. SHOWCASING
 TRANSPORTATION RELATED FEATURES (E.G. ROADWAY WIDTHS,
 DRIVING AISLES, PARKING STALLS, SIDEWALK, CURB, GUTTER,
 DRIVEWAY, GATES, CROSSWALKS, VISIBILITY TRIANGLE,
 CORNER & DRIVEWAY SEPARATION DISTANCES, SLOPES, ETC.)
 PROPERLY LABELED AND DIMENSIONED. THE SITE PLAN SHOULD
 BE NAMED T-1.0. PROPOSED TRAFFIC OPERATIONAL EXHIBIT IS
 INCOMPLETE
 5) PARTIALLY SATISFIED. IN THE T-1.0 SITE PLAN, PLEASE
 SHOWCASE BASIC CURB DETAILS (E.G. DRIVEWAY, CURB CUTS,
 PAVEMENT MARKINGS, PARKING STALLS, ETC.) ON THE
 OPPOSITE SIDE OF THE ROADS SURROUNDING THE PROPOSED
 DEVELOPMENT. PROPOSED TRAFFIC OPERATIONAL EXHIBIT IS
 INCOMPLETE
 6) NOT SATISFIED. PROVIDE A SIGNAGE AND PAVEMENT
 MARKING PLAN. INCLUSIVE OF ALL FEATURES WITHIN THE
 PROPOSED DEVELOPMENT AND ALONG ALL ROADS FRONTING THE
 SITE. THE SITE PLAN IS PART OF THE TRANSPORTATION
 REVIEW AND SHOULD BE NAMED ACCORDINGLY (E.G. T-1.1 OR
 T-2.0). THE PROPOSED TRAFFIC OPERATIONAL EXHIBIT DOES
 NOT CONTAIN THE REQUESTED INFORMATION
 7) NOT SATISFIED. PROVIDE AUTOTURN ANALYSIS FOR GARBAGE
 TRUCK AND/OR SERVICE VEHICLES DRIVING IN AND OUT OF THE
 PROPOSED DEVELOPMENT WITH VEHICLE DYNAMIC ENVELOPES AND
 WHEEL PATHS CLEARLY DISTINCT AND DEFINED IN DIFFERENT
 COLORS. SITE PLAN(S) CONTAINING THE ANALYSIS ARE PART
 OF THE TRANSPORTATION REVIEW AND SHOULD BE NAMED
 ACCORDINGLY (E.G. T1.2, T-3.0). NO REVISED PLANS IN
 LATEST SUBMISSION
 8) NOT SATISFIED. PROVIDE ENGINEERING REFERENCE AND
 SPECS SHEETS FOR EACH OF THE PROPOSED TRANSPORTATION
 FEATURES (E.G. CURB, RAMP, GATE, SIGNAGE, PAVEMENT
 MARKING, SIGNAL, ETC.). PLEASE PROVIDE DOCUMENT NAME
 AND SHEET NUMBER, AS THE PROPOSED TRAFFIC OPERATIONAL
 EXHIBIT DOES NOT CONTAIN THE REQUESTED INFORMATION
 9) NOT SATISFIED. IDENTIFY AND DESIGNATE TWO EASILY
 ACCESSIBLE MICRO-MOBILITY STATION AREA (MINIMUM 8 X 20
 FEET) AND PROVIDE BASIC ELECTRIFICATION READINESS WITH
 THE FOLLOWING SPECS: A CONDUIT (2-INCH SCHEDULE 40 PVC)
 TO THE POWER SOURCE WITH AN ELECTRICAL PULL BOX (240V /
 10,000W CIRCUIT). PLEASE INSERT THIS FEATURE IN THE
 T-1.0 OR T1.1 SITE PLAN. IDEALLY, ONE STATION SHOULD BE
 LOCATED ON OLIVE, WHILE THE OTHER ON FLAGLER
 10) SATISFIED. PROVIDE A PARKING TABLE SHOWCASING THE
 NUMBER OF REQUIRED AND PROVIDED PARKING SPACES,
 INCLUSIVE OF ADA AND BICYCLE ONES. NO REVISED PLANS IN
 LATEST SUBMISSION
 11) SATISFIED. IN THE PAVEMENT, MARKING & SIGN PLAN,
 PROVIDE A TABLE SHOWCASING THE NUMBER OF EXISTING AND
 PROPOSED ON-STREET PARKING STALLS. PROVIDE THE NUMBER
 OF METERED STALLS THAT ARE BEING REMOVED OR RELOCATED,
 IF ANY
 12) SATISFIED. ARE THERE ANY GATES PROPOSED? IF SO,
 CLEARLY SHOWCASE THE REQUIRED 20 FEET SETBACK DISTANCE
 FROM THE BACK OF THE SIDEWALK
 13) SATISFIED. ARE THERE ANY BUS STOPS BEING IMPACTED?
 14) SATISFIED. UNLESS THE ANGLE PARKING STALLS OF THE
 EASTERN PARKING LOT BY THE INTRACOASTAL ARE REVERSED,
 IT IS RECOMMENDED TO CHANGE DIRECTIONALITY. ENTRY
 DRIVEWAY SHOULD BE ON THE NORTH, WHILE EXIT ONE TO THE
 SOUTH
 15) SATISFIED. SOME OF THE STALLS AND DRIVE AISLE OF
 THE EASTERN PARKING LOT BY THE INTRACOASTAL ARE NOT
 CODE COMPLIANT. PLEASE REVISE ACCORDINGLY
 16) NOT SATISFIED. PICK-UP/DROP OFF AREA FOR THE
 ELEMENTARY SCHOOL SHOULD BE RELOCATED TO THE NORTHERN
 SIDE OF THE PARKING LOT, SO TO PROVIDE A LONGER STAKING
 DISTANCE. THERE IS A DISCREPANCY WITH THE PSP-1 SITE
 PLAN AND THE ONE SHOWN IN THE OPERATIONAL ANALYSIS. NO
 REVISED PLANS IN LATEST SUBMISSION
 17) SATISFIED. PICK-UP/DROP OFF AREA FOR THE EARLY
 CHILDHOOD SCHOOL SHOULD BE RELOCATED FURTHER SOUTH BY
 THE MIDDLE SCHOOL DROP OFF, SO TO PROVIDE A LONGER
 STAKING DISTANCE
 18) NOT SATISFIED. THE FOUR PARKING STALLS BY THE
 1-STORY GYMNASIUM SHOULD BE EITHER REMOVED, AND
 REPLACED BY A SIDEWALK SO TO PROVIDE LONGER STAKING BY
 DESIGNATING THE AREA FOR EARLY CHILDHOOD SCHOOL
 PICK-UP/DROP-OFF, OR CONVERTED TO ADA, AS THEY ARE THE
 CLOSEST AND SAFEST ONES TO THE ENTRANCE. THE REMOVAL OF
 SUCH STALLS WAS EXPLAINED AND AGREED UPON, AS BESIDES
 INCREASING THE QUEUE STACK, IT ALSO HELPS REDUCING
 CONFLICT POINTS AND INCREASING PEDESTRIAN SAFETY
 19) NOT SATISFIED. INSTALL HIGH VISIBILITY CROSSWALKS
 ACROSS 7TH AND 8TH ST AT THE INTERSECTION OF FLAGLER
 DR. PLEASE PROVIDE SPECIFICATIONS AND SHOWCASE THE ITEM
 ON THE PLANS
 20) SATISFIED. INSTALL A MINIMUM OF 8 FEET SIDEWALK
 ALONG THE NORTHERN SIDE OF 7TH ST
  
 VALERIO ORICCHIO
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]
  