Plan Review Notes
Plan Review Notes For Project Z22080016
Project Number Z22080016
Review Stop TRAFFIC
Sequence Number 1
Notes
Date Text
2022-09-07 20:56:33 
 1) GIVEN THE CHANGE IN SQUARE FOOTAGE, CIRCULATION AND
 DRIVEWAY CONFIGURATION. PROVIDE AN UPDATED TRAFFIC
 ANALYSIS
 2) PROVIDE A CLEAN TRANSPORTATION SPECIFIC SITE PLAN
 FOR THE GROUND FLOOR. SHOWCASING TRANSPORTATION RELATED
 FEATURES (E.G. ROADWAY WIDTHS, DRIVING AISLES, PARKING
 STALLS, SIDEWALK, CURB, GUTTER, DRIVEWAY, GATES,
 CROSSWALKS, VISIBILITY TRIANGLE, CORNER & DRIVEWAY
 SEPARATION DISTANCES, SLOPES, ETC.) PROPERLY LABELED
 AND DIMENSIONED. THE SITE PLAN SHOULD BE NAMED T-1.0
 3) IN THE T-1.0 SITE PLAN, PLEASE SHOWCASE BASIC CURB
 DETAILS (E.G. DRIVEWAY, CURB CUTS, PAVEMENT MARKINGS,
 PARKING STALLS, ETC.) ON THE OPPOSITE SIDE OF THE ROADS
 SURROUNDING THE PROPOSED DEVELOPMENT
 4) PROVIDE A SIGNAGE AND PAVEMENT MARKING PLAN.
 INCLUSIVE OF ALL FEATURES WITHIN THE PROPOSED
 DEVELOPMENT AND ALONG ALL ROADS FRONTING THE SITE. THE
 SITE PLAN IS PART OF THE TRANSPORTATION REVIEW AND
 SHOULD BE NAMED ACCORDINGLY (E.G. T-1.1 OR T-2.0)
 5) PROVIDE AUTOTURN ANALYSIS FOR GARBAGE TRUCK AND/OR
 SERVICE VEHICLES DRIVING IN AND OUT OF THE PROPOSED
 DEVELOPMENT WITH VEHICLE DYNAMIC ENVELOPES AND WHEEL
 PATHS CLEARLY DISTINCT AND DEFINED IN DIFFERENT COLORS.
 SITE PLAN(S) CONTAINING THE ANALYSIS ARE PART OF THE
 TRANSPORTATION REVIEW AND SHOULD BE NAMED ACCORDINGLY
 (E.G. T1.2, T-3.0)
 6) PROVIDE ENGINEERING REFERENCE AND SPECS SHEETS FOR
 EACH OF THE PROPOSED TRANSPORTATION FEATURES (E.G.
 CURB, RAMP, GATE, SIGNAGE, PAVEMENT MARKING, SIGNAL,
 ETC.)
 7) IDENTIFY AND DESIGNATE TWO EASILY ACCESSIBLE
 MICRO-MOBILITY STATION AREA (MINIMUM 8 X 20 FEET) AND
 PROVIDE BASIC ELECTRIFICATION READINESS WITH THE
 FOLLOWING SPECS: A CONDUIT (2-INCH SCHEDULE 40 PVC) TO
 THE POWER SOURCE WITH AN ELECTRICAL PULL BOX (240V /
 10,000W CIRCUIT). PLEASE INSERT THIS FEATURE IN THE
 T-1.0 OR T1.1 SITE PLAN. IDEALLY, ONE STATION SHOULD BE
 LOCATED ON OLIVE, WHILE THE OTHER ON FLAGLER
 8) PROVIDE A PARKING TABLE SHOWCASING THE NUMBER OF
 REQUIRED AND PROVIDED PARKING SPACES, INCLUSIVE OF ADA
 AND BICYCLE ONES
 9) IN THE PAVEMENT, MARKING & SIGN PLAN, PROVIDE A
 TABLE SHOWCASING THE NUMBER OF EXISTING AND PROPOSED
 ON-STREET PARKING STALLS. PROVIDE THE NUMBER OF METERED
 STALLS THAT ARE BEING REMOVED OR RELOCATED, IF ANY
 10) ARE THERE ANY GATES PROPOSED? IF SO, CLEARLY
 SHOWCASE THE REQUIRED 20 FEET SETBACK DISTANCE FROM THE
 BACK OF THE SIDEWALK
 11) ARE THERE ANY BUS STOPS BEING IMPACTED?
 12) UNLESS THE ANGLE PARKING STALLS OF THE EASTERN
 PARKING LOT BY THE INTRACOASTAL ARE REVERSED, IT IS
 RECOMMENDED TO CHANGE DIRECTIONALITY. ENTRY DRIVEWAY
 SHOULD BE ON THE NORTH, WHILE EXIT ONE TO THE SOUTH
 13) SOME OF THE STALLS AND DRIVE AISLE OF THE EASTERN
 PARKING LOT BY THE INTRACOASTAL ARE NOT CODE COMPLIANT.
 PLEASE REVISE ACCORDINGLY
 14) PICK-UP/DROP OFF AREA FOR THE ELEMENTARY SCHOOL
 SHOULD BE RELOCATED TO THE NORTHERN SIDE OF THE PARKING
 LOT, SO TO PROVIDE A LONGER STAKING DISTANCE. THERE IS
 A DISCREPANCY BETWEEN THE PSP-1 SITE PLAN AND THE ONE
 SHOWN IN THE OPERATIONAL ANALYSIS
 15) PICK-UP/DROP OFF AREA FOR THE EARLY CHILDHOOD
 SCHOOL SHOULD BE RELOCATED FURTHER SOUTH BY THE MIDDLE
 SCHOOL DROP OFF, SO TO PROVIDE A LONGER STAKING
 DISTANCE
 16) THE FOUR PARKING STALLS BY THE 1-STORY GYMNASIUM
 SHOULD BE EITHER REMOVED, AND REPLACED BY A SIDEWALK SO
 TO PROVIDE LONGER STAKING BY DESIGNATING THE AREA FOR
 EARLY CHILDHOOD SCHOOL PICK-UP/DROP-OFF, OR CONVERTED
 TO ADA, AS THEY ARE THE CLOSEST AND SAFEST ONES TO THE
 ENTRANCE
 17) INSTALL HIGH VISIBILITY CROSSWALKS ACROSS 7TH AND
 8TH ST AT THE INTERSECTION OF FLAGLER DR
 18) INSTALL A MINIMUM OF 8 FEET SIDEWALK ALONG THE
 NORTHERN SIDE OF 7TH ST
  
 VALERIO ORICCHIO
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]
  
  
  
  