| 2023-03-02 15:09:39 | ZONING AND PLANNING |
| | PROJECT: SOLESTE - 410 N. ROSEMARY AVE. |
| | DATE: 03.01.23 |
| | CONTACT: CLAUDIA IBAVEN, CITY URBAN DESIGNER, AT |
| | 561-822-1402 OR VIA [email protected]. |
| | I HAVE REVIEWED THE ABOVE REFERENCED PETITION AND |
| | PROVIDE THE FOLLOWING COMMENTS: |
| | |
| | ZONING DATA AND DIAGRAMS |
| | 1. ON SHEET A1.5, ACTIVE USE: PLEASE REVISE BOTH |
| | DIMENSIONS AND TABLE CALCULATIONS BASED ON THE |
| | FOLLOWING: |
| | - FACING N ROSEMARY AVE, THE DIMENSIONS OF THE |
| | 'BUILDABLE LOT FRONTAGE' OF THE NORTH BUILDING SHOULD |
| | BE FROM THE SETBACK TO THE SOUTH END OF THE OPEN SPACE. |
| | ACTIVE USE DIMENSION (179FT) IS NOT SHOWN ON THE TABLE. |
| | - FACING N ROSEMARY AVE, THE DIMENSIONS OF THE |
| | 'BUILDABLE LOT FRONTAGE' OF THE SOUTH BUILDING SHOULD |
| | BE FROM THE SETBACK TO NORTH END OF OPEN SPACE. |
| | COURTYARD SHOULD BE INCLUDED AS ACTIVE USE. |
| | - FACING W RAILROAD AVE, THE DIMENSION OF 'BUILDABLE |
| | LOT FRONTAGE' OF 196FT AND 'ACTIVE USE' OF 77FT DO NOT |
| | MATCH THE TABLE. |
| | - FACING 3RD STREET, PLEASE NOTE ENCLOSED STAIRS DO NOT |
| | COUNT AS ACTIVE USE, PLEASE EXCLUDE FROM DIMENSIONS AND |
| | CALCULATIONS. |
| | |
| | 2. ON SHEET A1.5, PLANAR BREAKS: THE COURTYARD ALSO IS |
| | A PLANAR BREAK, PLEASE INCLUDE IN YOUR CALCULATIONS. |
| | |
| | 3. ON SHEET A1.5, HORIZONTAL PROJECTIONS: THERE ARE |
| | DOTTED LINES THAT SEEM TO BE HORIZONTAL PROJECTIONS BUT |
| | ARE NOT COUNTED AS SUCH, PLEASE REVIEW. AND, PLEASE |
| | MAKE SURE HORIZONTAL PROJECTIONS MATCH OTHER PLANS AND |
| | RENDERINGS. |
| | |
| | 4. ON SHEET A1.4 - OPEN SPACE: PLEASE NOTE, THERE IS NO |
| | BREAKDOWN SHOWING WHERE THE 2,270SQ.FT. OF SEMI-OPEN |
| | SPACE IS COMING FROM. IN ADDITION, THERE ARE SOME |
| | WALK-UP GARDENS THAT LOOK DIFFERENT IN CONFIGURATION |
| | FROM THE SAMPLES. AND SAMPLES ARE SHOWING OVERHEAD |
| | COVERAGES DIFFERENT FROM FLOOR PLANS AND RENDERINGS. |
| | |
| | 5. ON SHEET A1.6, PLEASE CLARIFY WHY THE BUILDING'S |
| | FACADE DIMENSIONS ARE NOT MATCHING OTHER PLANS, |
| | EXAMPLE, ON SHEET A1.0 AND A1.5, THE NORTH BUILDING |
| | FRONTAGE IS 150FT. PLEASE ALSO REVIEW, SEC. 94-109, |
| | FIGURE IV-33 TO SEE TRANSPARENCY SAMPLE CALCULATION. |
| | |
| | 6. PLEASE EXPLAIN WHAT IS THE 'MARKET ROOM' ON THE |
| | NORTH BUILDING. |
| | |
| | |
| | PARKING |
| | 1. PLEASE NOTE, AS PER SEC. 94-111 (C) IN THOSE CASES |
| | WHERE THE SIDE OF ANY STALL IS ADJACENT TO A WALL, |
| | FENCE, BUILDING, OR OTHER PHYSICAL OBSTRUCTION, THE |
| | STALL WIDTHS SHALL BE INCREASED BY A MINIMUM OF ONE |
| | FOOT. WHERE THERE IS AN OBSTRUCTION ON BOTH SIDES OF |
| | THE STALL, THE STALL WIDTHS SHALL BE INCREASED BY A |
| | MINIMUM OF TWO FEET. ON A2.2 SHEET, TANDEM PARKING |
| | SPACES LOCATED ON THE SOUTHEAST OF THE PARKING GARAGE |
| | IN THE SOUTH BUILDING ARE SHOWING AGAINST WALLS |
| | ENCLOSING STAIRS. |
| | |
| | 2. PLEASE PROVIDE ADA RAMPS SHOWING SLOPE RATIO AND |
| | DIMENSIONS. PLEASE MAKE SURE CHANGES ARE REFLECTED ON |
| | ALL PLANS. |
| | |
| | 3. PLEASE CLARIFY IF THE PARKING GARAGE GATES ARE NO |
| | LONGER PROPOSED AND PARKING LOTS ARE ACCESSIBLE 24/7. |
| | AND, WHAT SECURITY MEASURES WILL BE PROPOSED FOR |
| | OPERATIONS? |
| | |
| | 4. PER SEC. 94-111, ALL PARKING STRUCTURE ENTRANCES |
| | FACING A STREET FRONTAGE SHALL BE REQUIRED TO TREAT THE |
| | INTERIOR PORTION OF THE GARAGE ENTRY TO A DEPTH OF AT |
| | LEAST 20 FEET FROM THE BUILDING FACADE. TREATMENT MAY |
| | INCLUDE, BUT SHALL NOT BE LIMITED TO, STUCCO OR |
| | PLASTER, FINISHED AND PAINTED COMPARABLE TO A HABITABLE |
| | SPACE. ALL MECHANICAL, ELECTRICAL, AND PLUMBING SYSTEMS |
| | SHALL BE COVERED OR SCREENED. |
| | |
| | |
| | |
| | STREETSCAPE AND LANDSCAPE |
| | 1. OPEN SPACE DIAGRAMS DO NOT MATCH LANDSCAPE PLANS AND |
| | WE ARE UNABLE TO DETERMINE ON WHETHER THESE SPACES MEET |
| | THE LANDSCAPE AND OPEN SPACE REQUIREMENTS. PLEASE NOTE, |
| | LOADING AREAS AND TRAVEL ROUTES CANNOT GO OVER |
| | LANDSCAPE, TREES, OR SIDEWALKS. SEE ALSO ZONING DATA |
| | AND DIAGRAMS COMMENT #4. |
| | |
| | 2. ON SHEET A1.0, EXISTING CROSSING ON N ROSEMARY AND |
| | 4TH ST DOES NOT MEET SIDEWALK. |
| | |
| | 3. PLEASE NOTE ON ENGINEERING PLANS YOU ARE SHOWING |
| | CURB RAMPS ON CROSSINGS AND DRIVEWAYS, PLEASE MAKE SURE |
| | TO ADD THOSE TO THE SITE PLAN. |
| | |
| | 4. PLEASE PROVIDE DETAILS ON THE TYPE OF PAVEMENT |
| | TREATMENT ON CROSSINGS, WALKWAYS, OPEN SPACES, ETC., |
| | SUCH AS STAMP CONCRETE, PAVERS, ETC. |
| | |
| | 5. PLEASE SHOW LIGHTING POLES ON SITE PLAN AS PROPOSED |
| | IN YOUR PHOTOMETRIC PLANS E1. PLEASE NOTE, YOU WILL |
| | NEED TO UPDATE YOUR PHOTOMETRIC PLANS BASED ON CHANGES. |
| | |
| | |
| | ELEVATIONS |
| | 1. PLEASE CLARIFY IF THE SCREENING ON THE BRIDGE IS |
| | DIFFERENT ON BOTH FACADES, NORTH AND SOUTH, AS SHOWN ON |
| | ELEVATIONS. ALSO CLARIFY, IF COLUMNS ON BRIDGE ARE |
| | DIFFERENT IN SIZE; ON THE WEST ELEVATION, COLUMNS LOOK |
| | WIDER AND PAINTED BLUE, ON EAST ELEVATION, COLUMNS AND |
| | ARE THINNER AND PAINTED WHITE. |
| | |
| | 2. PLEASE MAKE SURE TO ALSO POINT OUT PILASTERS ON |
| | SHEET A3.2A OR ANY OTHER DECORATIVE TREATMENT PROPOSED |
| | ON FACADES. AND, PLEASE ADD METAL RAILINGS DETAIL. |
| | |
| | 3. PLEASE NOTE, SOME DOORS ON ELEVATIONS DO NOT MEET |
| | THE SIDEWALK LEVEL AND HAVE NOT STEPS. SEE EAST |
| | ELEVATION CLOSER TO THE NORTH AND ADD ELEVATION LEVEL |
| | TO SIDEWALKS. |
| | |
| | |
| | SECTIONS |
| | 1. PLEASE ADD ELEVATION LEVELS TO SIDEWALKS. |
| | |
| | 2. ON SHEET A4.1, SECTION A, SOME STAIRS ON LOBBIES ARE |
| | NOT MEETING THE SIDEWALK LEVELS. |
| | |
| | 3. ON SHEET A4.2, SECTION C DOES NOT MATCH FLOOR PLAN |
| | AS PARKING CLOSER TO THE WEST IS AT 6FT LEVEL. IN |
| | ADDITION, THE MAIL ROOM SEEMS TO BE CONNECTED TO THE |
| | PACKAGE ROOM AND MAIL ROOM LOOKS LIKE IT IS AT 6FT |
| | LEVEL AND PACKAGE ROOM AT 3FT LEVEL. AND, UNITS ON |
| | SECTION ARE NOT AT 6FT LEVEL AS SHOWN ON FLOOR PLANS. |
| | |
| | 4. ON SHEET A4.1 SECTION B AND SHEET A3.2, SOUTH |
| | ELEVATION- 4TH ST. PLEASE EXPLAIN HOW THESE MAIN |
| | ENTRANCES TO THE BUILDINGS ARE HIGHLIGHTED WITH THE |
| | DESIGN. PERHAPS MORE TRANSPARENCY CAN BE ADDED OR USE |
| | OF DIFFERENT MATERIALS OR COLORS. AS WELL AS |
| | LANDSCAPING OR HARDSCAPE TO ELEVATE THE DESIGN. |
| | |
| | |
| | RENDERS |
| | 1. PLEASE MAKE SURE RENDERS MATCH LANDSCAPING AND |
| | STREETSCAPE. |
| | |
| | |
| | OTHER COMMENTS: |
| | PLEASE NOTE, AS PER SEC. 94-54 (A)(1), THE APPLICANT |
| | SHALL ADDRESS ANY COMMENTS OF THE PPRC AND SUBMIT A |
| | REVISED APPLICATION WITHIN 60 DAYS OF THE DATE OF SUCH |
| | COMMENTS. FAILURE TO MAKE THE REQUIRED SUBMITTALS |
| | WITHIN THE 60-DAY DEADLINE WILL DEEM THE APPLICATION AS |
| | WITHDRAWN. AT LEAST 15 DAYS PRIOR TO THE EXPIRATION OF |
| | THE 60-DAY REVISION PERIOD, THE APPLICANT MAY REQUEST A |
| | 30-DAY EXTENSION. NO FURTHER EXTENSION REQUEST IS |
| | PERMITTED. COMMENTS RELATING TO REVISED APPLICATIONS |
| | SHALL BE ADDRESSED WITHIN 30 DAYS OF THE DATE OF SUCH |
| | COMMENTS. |
| | |
| | WHEN RESUBMITTING, WRITTEN RESPONSES TO COMMENTS NEED |
| | TO BE PROVIDED AS WELL AS A MINIMUM OF TWO (2) PAPER |
| | COPIES AND AN ELECTRONIC COPY IN .PNG/.PDF FORMAT OF |
| | ALL PLANS AND ALL DOCUMENTATION REQUIRED IN THE |
| | APPLICATION. PLEASE NOTE THAT CHANGES ON THE |
| | RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS |
| | TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL |
| | COMMENTS. |
| | |
| | LASTLY, YOU WERE PERMITTED ONE (1) RESUBMITTAL AT NO |
| | ADDITIONAL COST. AS PREVIOUSLY ISSUED COMMENTS CONTINUE |
| | TO NOT BE SUFFICIENTLY ADDRESSED, THE APPLICANT WILL BE |
| | ASSESSED A RESUBMITTAL FEE. SUCH FEE WILL BE 20% OF THE |
| | ORIGINAL APPLICATION FEE. |
| | |
| |