Plan Review Notes
Plan Review Notes For Project Z22080012
Project Number Z22080012
Review Stop Z
Sequence Number 1
Notes
Date Text
2022-09-07 15:31:021. ACTIVE USE: PLEASE NOTE THAT ACTIVE USES ARE
 REGULATED AS A PERCENTAGE OF THE BUILDABLE LOT
 FRONTAGE, NOT THE BUILDING FRONTAGE. PLEASE ADJUST
 CALCULATIONS ACCORDINGLY. THE PERCENTAGE SHOULD BE 80%
 OF THE ENTIRE N ROSEMARY AVE. PROPERTY LINE (60% FOR
 LINERS 2-5), 30% OF THE 3RD ST. PROPERTY LINE, AND THEN
 30% OF THE W. RAILROAD AVE. PROPERTY LINE.
  
 2. PLEASE PROVIDE OWNERS CONSENT OR PROOF OF AGREEMENT
 BETWEEN THE NEIGHBORING PROPERTY OWNER OF 411 W
 RAILROAD AVE. TO ALLOW FOR THE EXTENSION OF 4TH ST.
 OVER THEIR PROPERTY.
  
 3. RADIUS OF THE CURB-CUT OR APRON FOR THE NORTHERN
 SERVICE ACCESS ENCROACHES INTO CITY PROPERTY, PLEASE
 ADJUST.
  
 4. THE SERVICE ACCESS ALONG THE SOUTHERN AND NORTHERN
 SIDE OF THE PROPERTY DOES NOT PROVIDE REQUIRED 5 FT.
 LANDSCAPE BUFFER ALONG THE PROPERTY LINE AND TO SCREEN
 THE VEHICULAR USES. SERVICE ROADS WILL HAVE TO BE
 ADJUSTED TO ACCOMMODATE FOR THE BUFFER.
  
 5. SHEET A0.2 ? SITE INFORMATION TABLES REQUIRE
 CORRECTIONS:
 - IF LOT AREA IS 108,638; THEN WITH A 2.75 FAR MAXIMUM
 ALLOWED IS 298,755 SF, NOT 298,729 SF.
 - REQUIRED PRIVATE OPEN SPACE AT 25% IS 27,160 SF, NOT
 27,158 SF.
 - CONDITIONAL 50? SETBACK IS FROM ABOVE THE 5TH FLOOR,
 NOT THE 6TH.
 - GBA SHOULD MATCH FAR CALCULATION.
 - PLEASE DOUBLE CHECK ALL CALCULATIONS AND DIMENSIONS
 FOR CONSISTENCY ACROSS PLANS.
  
 6. OPEN SPACE REQUIREMENT:
 - PLEASE CLARIFY THE 4TH ST. EXTENSION. IS IT A PRIVATE
 ROAD WITH PUBLIC ACCESS AGREEMENT/EASEMENT? DOES IT
 SERVE AS A PUBLIC ROW?
 - IF 4TH ST. IS AN EXTENSION OF THE PUBLIC ROW, THEN IT
 REQUIRES A SETBACK ON EITHER SIDE AND SHOULD BE
 DESIGNED WITH STREETSCAPE REQUIREMENTS IN MIND. IF IT
 IS NOT CONSIDERED A PUBLIC ROW, THEN PUBLIC OPEN SPACE
 #2 DOES NOT MEET REQUIREMENT OF A COURTYARD TO HAVE
 PUBLIC ROW ABUTMENT. PUBLIC OPEN SPACES SHOULD NOT BE
 LOCATED ALONG THE PRIVATE DRIVE AS THAT IS NOT THE
 INTENTION OF THE CODE, SPACES SHOULD BE PUBLICALLY
 ACCESSIBLE AND VISIBLE; OTHERWISE, PEDESTRIANS WILL NOT
 UTILIZE THE SPACE AS DESIGNED.
 - ON SHEET A1.4 PUBLIC OPEN SPACE #1 AND #2 SHOULD BE
 COMBINED INTO A SINGLE SPACE, THE WALKWAY/SIDEWALK DOES
 NOT DELINEATE SEPARATE SPACES, AS IT IS SHOWN THE OPEN
 SPACE WOULD HAVE TO HAVE ITS PROPORTIONS CHANGED AS NO
 SINGLE SIDE CAN BE 5X THE LENGTH OF THE OTHER. THIS IS
 A VERY LINEAR OPEN SPACE.
 - WHAT IS THE GROUND LEVEL PRIVATE OPEN SPACE AT THE
 NORTH WEST CORNER OF SHEET L-1? IS THIS PART OF THE
 REQUIRED PRIVATE OPEN SPACE COUNT? SUGGEST EXPANDING
 2BR UNIT TO SCREEN LOADING/SERVICE ROAD FROM THE
 PRIVATE OPEN SPACE AND N ROSEMARY.
 - PLEASE PROVIDE CALCULATIONS FOR HOW THE PROPOSED OPEN
 SPACES MEET THE REQUIREMENTS FOR SIZE, ACTIVE USE
 ABUTMENT, ROW ABUTMENT, SEATING, VEGETATION, OVERHEAD
 COVER, ETC. AS IS APPLICABLE.
  
 7. PLEASE ADJUST GROSS BUILDING AREA (GBA) CALCULATIONS
 ON SHEET A0.2 AND A1.1:
 - GROSS BUILDING AREA MEANS THE TOTAL FLOOR AREA OF A
 BUILDING, INCLUDING AIR-CONDITIONED OR FULLY ENCLOSED
 STORAGE SPACES, ENCLOSED AREAS ON THE ROOFTOP, SUCH AS
 BATHROOMS AND LOBBIES, STAIRS AND ELEVATOR AREAS, AND
 EXTERNAL UNENCLOSED CIRCULATION AREAS. THE GROSS
 BUILDING AREA DOES NOT INCLUDE PARKING AREAS;
 UNENCLOSED COLONNADES, PORCHES AND BALCONIES;
 MECHANICAL AND ELECTRICAL SPACES; AND TRASH ROOMS.
 STORAGE SPACES WITHOUT WINDOWS AND ENCLOSED BY SURFACES
 THAT ALLOW FOR NATURAL VENTILATION OR OUTSIDE AIR
 CIRCULATION SHALL NOT BE INCLUDED.
 - THE GROSS BUILDING AREA SHALL BE MEASURED FROM THE
 OUTSIDE FACE OF EXTERIOR WALLS.
 - SHEET A1.1 AND A1.2 SHOULD MATCH IN TERMS OF TOTALS.
  
 8. SHEET A1.0 PLEASE PROVIDE ALL CURBCUT WIDTH
 DIMENSIONS ALONG PROPERTY LINE, CANNOT EXCEED 25?.
  
 9. ON SHEET L-1 AND A1.0 STREETSCAPE AND LANDSCAPE
 REQUIREMENTS NOT MET:
 - STREET TREES ARE REQUIRED TO BE ADJACENT TO THE CURB,
 N ROSEMARY AVENUE SIDE ON FEATURES 5 (EXISTING) TREES,
 REQUIREMENT IS TREES SPACED OUT AT A MAX. OF 30 FT. ON
 CENTER; APPROX. 16 STREET TREES REQUIRED ALONG N
 ROSEMARY.
 - FURTHER DISCUSSION IS NECESSARY WITH CRA AS THERE ARE
 PLANS TO RECONFIGURE THE N ROSEMARY STREETSCAPE.
 - PLEASE ILLUSTRATE THE SITE VISIBILITY TRIANGLES FROM
 ALL INTERSECTIONS IN ACCORDANCE WITH SEC. 94-305(E.) ?
 LANDSCAPE APPEARS TO IMPEDE.
  
 10. PLEASE PROVIDE SETBACK LINES ON ALL ELEVATIONS.
  
 11. PLEASE PROVIDE SEPARATE SHEETS ON FACADE
 ARTICULATION AND HOW THE PROJECT MEETS PLANAR BREAK
 REQUIREMENTS, TRANSPARENCY/FENESTRATION REQUIREMENTS,
 AND PROVIDE ADDITIONAL DETAILS FOR ANY PROJECTIONS,
 SCREENING, OR ARCHITECTURAL FEATURES.
  
 12. THE WALLS ON THE INTERIOR OF THE PUBLIC OPEN SPACE
 COURTYARD (BETWEEN 4TH AND 3RD) ARE BLANK, PLEASE
 PROVIDE SOME FENESTRATION, ARCHITECTURAL TREATMENT OR
 FACADE ARTICULATION ON THESE WALLS.
 - NORTHERN FA?ADE OF THE BUILDING (FACING SALVATION
 ARMY) APPEARS TO HAVE A LARGE BLANK WALL (>20%) PLEASE
 PROVIDE ADDITIONAL FENESTRATION, ARCHITECTURAL
 TREATMENT OR FACADE ARTICULATION TO THIS FRONTAGE.
 - WEST RAILROAD AVENUE, GROUND LEVEL FACADE WOULD
 BENEFIT FROM ADDITIONAL ARTICULATION.
  
 13. BICYCLE PARKING REQUIRES 1 SPACE PER EVERY 100 FT.
 OF FRONTAGE, PUBLICLY ACCESSIBLE ALONG ROW/CURB (~5-6
 SPACES ON ROSEMARY; ~2 SPACES ON 3RD; ~3 SPACES ON W
 RAILROAD.)
  
 14. PLEASE INDICATE LOCATION OF BIKE ROOM, PROVIDE
 DETAILS OF HOW ROOM IS ACCESSED, AND PROVIDE THE TYPE
 OF RACKS OR DETAIL HOW THE BIKES ARE SECURED WITHIN THE
 ROOM.
  
 15. PLEASE PROVIDE PARKING STALL DETAILS, MAKE SURE THE
 STRIPING AND DIMENSIONS MEET CITY STANDARD. PLEASE
 PROVIDE DRIVE AISLE WIDTH, REQUIRED 24FT. MINIMUM.
 PLEASE PROVIDE PARKING RAMP SLOPES. PROVIDE DIMENSION
 OF LOADING AREA.
  
 16. FOR DAC PLEASE PROVIDE ACCURATE AND FULL DETAIL
 RENDERS OF THE PROJECT.
  
 17. CITY/CRA IN PARTNERSHIP WITH GEHL HAS PRODUCED A
 STUDY TO REDEVELOP N ROSEMARY AVENUE AND ITS
 STREETSCAPE, AS PART OF THIS STUDY N ROSEMARY IS TO BE
 A MORE ACTIVE FRONTAGE.
 - CRA RECOMMEND INCORPORATING GROUND-LEVEL COMMERCIAL
 USES ALONG THE PORTION OF N. ROSEMARY AND THE 3RD ST.
 FRONTAGE OR CORNER. FROM 3RD ST. TO 4TH ST.
 COMMERCIAL/RETAIL OPPORTUNITIES FOR BOTH THE PROJECT'S
 RESIDENTS AS WELL AS THE SURROUNDING NEIGHBORHOOD.
 - PORTION FROM 4TH ST. UP TO THE SALVATION ARMY
 PROPERTY LINE CAN REMAIN AS THE WALK-UP UNITS. HOWEVER
 ADDITIONAL GROUND-LEVEL RETAIL IS ENCOURAGED BY CRA.
 - RELOCATE INTERIOR LOBBY TO THE INTERSECTION OF 4TH
 AND N ROSEMARY, MIRROR THE CONDITION ON THE 2ND
 BUILDING'S LOBBY.
 - SUGGEST FURTHER DISCUSSION WITH CRA.
  
 18. RECOMMEND EXPLORING ADDITIONAL ARCHITECTURAL
 TREATMENTS, FACADE ARTICULATION, OR DESIGNS TO THE
 CORNER/INTERSECTION OF 3RD AND N ROSEMARY. THIS IS A
 FOCAL POINT AND SERVES AS A GATEWAY INTO THE NORTHWEST
 NEIGHBORHOOD, GREAT OPPORTUNITY TO MAKE A STANDOUT OR
 SPECIAL FRONTAGE.
  
 19. ON SHEET A1.1 AND A1.2, THE DIAGRAM FOR LEVEL 4 AND
 LEVEL 8 ARE MISSING, VALUES ARE SHOWN IN TABLE.
  
 20. SHEET A2.3 THE BRIDGE SPANNING OVER 4TH ST. SHOWS
 PARKING SPACES, HOWEVER THERE ARE SEVERAL WALLS DRAWN,
 PLEASE CLARIFY HOW THIS BRIDGE/SPACE FUNCTIONS. WHAT IS
 THE GREY ROOM TO THE LEFT OF THE BRIDGE PARKING; IS
 THIS STORAGE?
  
 21. SHEET A4.1 & A4.2, PLEASE EXPLAIN OR CLARIFY HOW
 THE BRIDGE AND PARKING LEVELS RELATE TO THE OVERALL
 FLOOR PLATES OF THE BUILDING, DOES NOT APPEAR TO BE
 LEVEL/LOOKS TO BE A HALF OR QUARTER-FLOOR DIFFERENCE IN
 THE ALIGNMENT. HOW DOES THIS SPACE FUNCTION IN RELATION
 TO THE OVERALL BUILDING? INTERNALLY RAMPS UP?
  
 22. UPDATED RENDERS PROVIDED ON 9.8.22 SHOW THE
 GROUND-LEVEL WALKUP UNITS ENCLOSED BY A RAILING OR
 FENCE, WHAT IS THE TOTAL HEIGHT OF THE WALL + RAILING?
  
 23. PER CONVERSATION WITH HISTORIC PRESERVATION STAFF,
 WHILE THE PROJECT LIES OUTSIDE OF THE BOUNDARIES FOR
 THE NORTHWEST NEIGHBORHOOD, STAFF ENCOURAGES DESIGN
 THAT PROVIDES RELATIONSHIP OR REFERENCE TO THE HISTORIC
 NATURE OF THE NEIGHBORHOOD THIS PROJECT FACES/OPENS TO.
 ADDITIONAL ARCHITECTURAL ELEMENTS TO CONSIDER INCLUDE:
 ANGLED CORNERS ON THE BALCONIES CONNECTING TO THE
 BUILDING FA?ADE (CREATING A TRAPEZOID LOOK), CABLED
 SUPPORTS FROM THE BALCONIES TO THE BUILDING FA?ADE
 (MIMIC AWNING OR CANOPY SUPPORTS), A THICKER BALCONY
 SLAB FOR THE BALCONY ABOVE THE 3RD ST. ACCESS ROAD
 (CREATING MORE OF A MARQUEE ELEMENT), AND OPENING UP
 THE CORNER OF 3RD AND N ROSEMARY BY SETTING THE MASS
 BACK AND CREATING A FOCAL POINT AT THE CORNER.
  
 CHRIS KIMMERLY, AICP
 URBAN DESIGN PLANNER
 822.1426 [email protected]
  