Plan Review Notes
Plan Review Notes For Project Z22070024
Project Number Z22070024
Review Stop Z
Sequence Number 2
Notes
Date Text
2023-05-01 15:34:421. SETBACKS:
 - PLEASE PROVIDE SETBACK LINES ON SITE PLAN AND
 ARCHITECTURAL DRAWINGS
 - SETBACKS NEED TO BE RECALCULATED AND LABELED:
 - 10TH STREET IS FRONT, MIN. 20 FT. SETBACK REQUIRED
 - RAILROAD AVENUE IS SIDE STREET, 0 FT. SETBACK
 REQUIRED
 - ALLEY, 5 FT. MIN. SETBACK REQUIRED - SIDE INTERIOR
 MIN. 25 FT. SETBACK REQUIRED FOR MIXED USE FRONTING RR
 AVE.
 RESPONSE: IN ORDER TO ENCOURAGE AND DIRECT PUBLIC
 ACTIVITY AND MOVEMENT ALONG N. RAILROAD AVENUE, THE
 APPLICANT ORIENTED THE PUBLIC ACCESS TO 444 ALONG N.
 RAILROAD AVENUE AND PLACED ALL BACK-OF-HOUSE SERVICES
 (I.E. LOADING, PARKING, TRASH ENCLOSURE, UTILITIES) TO
 THE REAR OF THE PROPERTY. AS SUCH, THE ALLEY AND 10TH
 STREET FRONTAGES HAVE BEEN TREATED AS ???SIDE STREET
 RESIDENTIAL??? AND ???ALLEY??? BUFFERS BASED ON THIS
 UPDATED BUILDING AND SITE PROGRAMMING. THE APPLICANT
 RESPECTFULLY REQUESTS THAT THE NORTH BUFFER BE
 CONSIDERED A ???SIDE RESIDENTIAL STREET??? BUFFER TO
 MAXIMIZE THE AMOUNT OF ACTIVE BUILDING FRONTAGE THAT
 CAN BE CREATED/PROGRAMMED ALONG N. RAILROAD FOR THE
 BENEFIT OF THE URBAN STREETSCAPE THAT IS ATTEMPTING TO
 BE CREATED ALONG THIS CORRIDOR.
 1. ZONING REVIEW 5.1.23 ??? [PARTIALLY SATISFIED]
 AFTER STAFF REVIEW OF BPD-R PROVISIONS; SETBACKS SHALL
 BE SUCH:
 RAILROAD AVENUE ??? 0???
 ALLEY ??? 5???
 SIDE RESIDENTIAL STREET (10TH ST. FRONTAGE) ??? 10???
 SIDE INTERIOR SETBACK (EASTERN PROPERTY LINE) ??? 25???
 NO REAR OR FRONT SETBACKS BY CODE BECAUSE OF COMMERCIAL
 PROPERTY FRONTING RAILROAD.
 STAIRCASE ENCROACHES INTO SIDE INTERIOR SETBACK BY
 1.5FT. PLEASE ADJUST.
  
 2. PARKING REQUIREMENTS:
 - PLEASE PROVIDE BREAKDOWN OF OFFICE AND RETAIL SF.
 BOTH 7,900 SF?
 - WHAT IS WIDTH OF PARKING DRIVE? APPEARS TO BE 24FT
 BUT PLEASE BE SURE TO FALL UNDER 25FT MAXIMUM WIDTH.
 - PAINTING/STRIPING DETAILS NEED TO MEET CITY STANDARD
 FOR STALL
 - SITE PLAN MENTIONS PARKING REQUIREMENTS BEING MET
 WITH VALET SERVICE OFFSITE, PLEASE INDICATE WHERE THE
 OFF-SITE PARKING IS LOCATED.
 RESPONSE: THE BUILDING SQUARE FOOTAGE IS DIVIDED
 EQUALLY INTO GROUND FLOOR RETAIL/RESTAURANT AND SECOND
 STORY OFFICE USES (7,900 SF RESPECTIVELY). THE PARKING
 DRIVE AISLE IS 24 FEET WIDE AND A DIMENSION HAS BEEN
 ADDED TO THE PLAN TO IDENTIFY SAID WIDTH. THE PARKING
 STRIPING HAS BEEN UPDATED TO MATCH THE CITY STANDARDS.
 A NOTE HAS BEEN ADDED TO THE SITE PLAN INDICATING THE
 LOCATION OF THE OFFSITE PUBLIC AND VALET PARKING LOTS
 THAT SERVE THE VARIOUS USES WITHIN NORA.
 2. ZONING REVIEW 5.1.23 ??? [SATISFIED]
  
 3. SANITATION/LOADING: PLEASE PROVIDE AUTOTURN ANALYSIS
 FOR ALLEY AND LOADING AREA.
 RESPONSE: ACKNOWLEDGED. AN AUTOTURN ANALYSIS HAS BEEN
 PREPARED TO IDENTIFY THE ABILITY OF UTILITY VEHICLES TO
 ACCESS THE TRASH ENCLOSURE AND THE LOADING ZONE.
 3. ZONING REVIEW 5.1.23 ??? [NOT SATISFIED] NO AUTOTURN
 PROVIDED IN SUBMITTAL PACKAGE
  
 4. PHOTOMETRIC ANALYSIS SHOWS PROPERTY AS A 1-STORY
 10,185 SF BUILDING, PLEASE BE CONSISTENT ACROSS PLAN
 SETS.
 RESPONSE: ACKNOWLEDGED. THE PHOTOMETRIC PLAN SHALL BE
 UPDATED FOR BACKGROUND CONSISTENCY.
 4. ZONING REVIEW 5.1.23 ??? [SATISFIED]
  
 5. CURB CUT FOR TRASHCAN/ALLEY CUTS INTO ADJACENT
 RESIDENTIAL PROPERTY. PLEASE ADJUST.
 RESPONSE: ACKNOWLEDGED. THE RADIAL CURB HAS BEEN
 REPLACED WITH A FLARE TO AVOID CONFLICT/ENCROACHMENT
 WITH THE ADJACENT PROPERTY TO THE EAST. SEE UPDATED
 SITE AND LANDSCAPE PLANS.
 ZONING REVIEW 5.1.23 ??? [SATISFIED]
  
 6. PLEASE INDICATE WHERE REQUIRED BIKE PARKING SPACES
 ARE LOCATED
 RESPONSE: ACKNOWLEDGED. BIKE RACK HAVE BEEN PROVIDED
 THROUGHOUT NORA WITHIN THE PREVIOUSLY APPROVED
 STREETSCAPE PLAN AND PUBLIC OFF-STREET PARKING PLAN
 PROJECTS. AN ADDITIONAL BIKE RACK HAS BEEN SPECIFIED AT
 THE REAR OF THE BUILDING IN THE PAVER PLAZA AREA.
 ZONING REVIEW 5.1.23 ??? [SATISFIED]
  
 7. PLEASE PROVIDE STREETSCAPE LANDSCAPING DETAILS FOR N
 RAILROAD AVE. AND 10TH ST. FRONTAGES.
 RESPONSE: ACKNOWLEDGED. LANDSCAPE DETAILS HAVE BEEN
 PROVIDED FOR BOTH RIGHTS-OF-WAYS ALONG THE BOUNDARY OF
 THE SUBJECT SITE.
 ZONING REVIEW 5.1.23 ??? [SATISFIED]
  
 8. 5FT. LANDSCAPE BUFFER BETWEEN ADJACENT TO
 RESIDENTIAL USES REQUIRES INSTALLATION OF A WALL.
 RESPONSE: ACKNOWLEDGED. A WALL SHALL BE ADDED ALONG
 THE EAST PROPERTY BOUNDARY AS REQUIRED. SEE UPDATED
 SITE AND LANDSCAPE PLAN.
 PLEASE PROVIDE HEIGHT DETAIL OF MASONRY WALL
  
 NEW ZONING COMMENTS 5.1.23:
 1. PLEASE PROVIDE PROJECTION DETAILS OR DIMENSIONS FOR
 THE CANOPY ELEMENTS SHOWN ON THE ELEVATIONS. BE SURE
 THAT THESE ELEMENTS MEET THE STANDARDS IN SEC. 94-109
 TABLE IV-5. ELEVATIONS PROVIDED, PLEASE SHOW
 PROJECTIONS.
  
 2. ANY ROOFTOP MECHANICAL EQUIPMENT SHALL BE SCREENED
 FROM VIEW. PER SEC. 94-109 PROJECTION, VERTICAL:
 MECHANICAL EQUIPMENT AND APPURTENANCES NECESSARY TO THE
 OPERATION OR MAINTENANCE OF THE BUILDING OR STRUCTURE
 ITSELF SUCH AS, BUT NOT LIMITED TO, COOLING TOWERS,
 ELEVATORS, STAIRS AND MECHANICAL PENTHOUSES, VENT
 STACKS AND ANTENNAS SHALL BE ENCLOSED AND SCREENED IN
 SUCH A MANNER THAT THE ENCLOSURE IS DESIGNED AS AN
 INTEGRAL PART OF THE OVERALL BUILDING DESIGN.
 3. FOR THE LANDSCAPING ON SHEET LP-1:
 SEC.94-113(D.) AND SEC.94-113(G.) APPLIES
 SEC. 94-443(A.)(1.) PROTECTIVE SCREEN WALLS AND
 (2.)LANDSCAPE BUFFER APPLIES; THESE SECTIONS PROVIDE
 MORE DETAIL ON THE REQUIREMENTS OF SEC. 94-113(G.)
 PLEASE AMEND LP-1 & LP-2 TO REFLECT THE THREE
 APPLICABLE CODE SECTIONS ABOVE AND THEIR REQUIREMENTS.
 THE REFERENCE TO 94-442 CAN BE REMOVED.
  
  