| Date |
Text |
| 2022-08-08 12:08:56 | 1. FLOOR PLAN DOES NOT MATCH SITE PLAN, PLEASE |
| | COORDINATE PLANS APPROPRIATELY. |
| | - SHOWS STAIRWELL IN PATH OF DRIVE AISLE AND |
| | INGRESS/EGRESS |
| | - SHOWS TWO-WAY TRAFFIC FLOW |
| | - SHOWS 8 PARKING SPACES ON SITE, DOES NOT PROVIDE ADA |
| | SPACE |
| | - SERVICE COURT/PARKING LOT APPEARS TO EXTEND ACROSS |
| | THE PROPERTY FROM 8TH TO ALLEY |
| | |
| | 2. SETBACKS |
| | - PLEASE PROVIDE SETBACK LINES ON SITE PLAN AND |
| | ARCHITECTURAL DRAWINGS |
| | - SETBACKS NEED TO BE RECALCULATED AND LABELED |
| | - NORTH RAILROAD AVENUE, REQUIRES 0FT SETBACK |
| | - REAR, REQUIRES 20FT SETBACK |
| | - ALLEY FOR COMMERCIAL USES, REQUIRES 5FT SETBACK |
| | - SIDE RESIDENTIAL STREET (10TH), REQUIRES 10FT |
| | |
| | 3. SITE PLAN MENTIONS PARKING REQUIREMENTS BEING MET |
| | WITH VALET SERVICE OFFSITE, PLEASE INDICATE WHERE THE |
| | OFF-SITE PARKING IS LOCATED. |
| | - IS ALL OF THE PARKING UNDER A VALET SERVICE? |
| | |
| | 4. WHERE IS THE LOADING OPERATION LOCATED? DETAIL IS |
| | SHOWN ON SITE PLAN, BUT NO LOCATION INDICATED. PLEASE |
| | CLARIFY IS THE SERVICE COURT ALSO SERVING AS LOADING |
| | SPACE? |
| | |
| | 5. PHOTOMETRIC ANALYSIS SHOWS SOUTHEASTERN CORNER OF |
| | PROPERTY ALONG ALLEY/ADJACENT TO HVL WITH AREAS BELOW |
| | REQUIRED 0.6 FOOTCANDLES. |
| | |
| | 6. PLEASE PROVIDE AUTOTURN ANALYSIS FOR |
| | SANITATION/LOADING ACCESS |
| | |
| | 7. PLEASE INDICATE WHERE REQUIRED BIKE PARKING SPACES |
| | ARE LOCATED. |
| | |
| | 8. PLEASE PROVIDE STREETSCAPE LANDSCAPING DETAILS FOR N |
| | RAILROAD AVE. AND 8TH ST. FRONTAGES. |
| | |
| | 9. PLEASE PROVIDE COMPLETE LANDSCAPE PLAN WITH CHARTS |
| | AND CALCULATIONS. |
| | |
| | 10. 5FT. LANDSCAPE BUFFER BETWEEN ADJACENT TO |
| | RESIDENTIAL USES REQUIRES INSTALLATION OF A WALL. |
| |
Print |