Plan Review Notes
Plan Review Notes For Project Z22070022
Project Number Z22070022
Review Stop Z
Sequence Number 2
Notes
Date Text
2023-05-01 16:21:201. SETBACKS
 - PLEASE PROVIDE SETBACK LINES ON ALL SITE PLAN AND
 ARCHITECTURAL DRAWINGS
 SETBACKS NEED TO BE RECALCULATED AND LABELED:
 - 7TH STREET IS FRONT, PRIMARY PEDESTRIAN ON THIS
 FRONTAGE REQUIRES 16??? SETBACK
 - NORTH RAILROAD AVENUE IS SIDE STREET, PRIMARY
 PEDESTRIAN REQUIRES 16??? SETBACK
 - REAR IS ALLEY, REQUIRES 5??? SETBACK
 - SIDE INTERIOR IS EAST PROPERTY LINE, REQUIRES 0? OR
 NFPA
 RESPONSE: PER A MEETING WITH STAFF THE SETBACKS ARE
 ALIGNED WITH THE APPLICANTS SITE PLAN PROGRAMMING WITH
 N. RAILROAD AS A FRONT SETBACK (0???); 7TH STREET AS A
 FRONT SETBACK (16???); ALLEY AT NORTH BOUNDARY AS SIDE
 INTERIOR (5??? 0??? PROVIDED EXISTING CONDITION); AND,
 EAST BOUNDARY AS REAR SETBACK (5??? FOR NON-RESIDENTIAL
 / 5??? PROPOSED FOR ADDITION).
 1. ZONING REVIEW 5.1.23 ??? [NOT SATISFIED]
 DISCUSSION WAS REGARDING THE BPD-R SETBACKS WHICH HAVE
 A PROVISION SPECIFICALLY CALLING OUT RAILROAD AVE.
 SETBACKS. THE BPD-5 SUBDISTRICT DOES NOT CALL OUT
 RAILROAD AVE., HOWEVER BECAUSE THIS PROPERTY IS NOT IN
 A RESIDENTIAL SUBDISTRICT THE SETBACKS ARE CALCULATED
 FROM BACK OF CURB, NOT PROPERTY LINE.
 SETBACKS STILL APPEAR TO BE MET, JUST NEED TO BE
 PROPERLY LABELED.
 RAILROAD AVE. IS A PRIMARY PEDESTRIAN STREET THEREFORE
 16??? IS REQUIRED ON THIS FRONTAGE (FROM CURB)
 7TH STREET IS A PRIMARY PEDESTRIAN SETBACK REQUIRES
 16??? SETBACK (FROM CURB)
 ALLEY IS CONSIDERED REAR AND WOULD REQUIRE 5???
 (EXISTING STRUCTURE WOULD BE CONSIDERED LEGAL
 NONCONFORMITY)
 SIDE INTERIOR IS EASTERN PROPERTY LINE, REQUIRES 0???
 OR NFPA.
  
 2. LANDSCAPING
 - 12% PRIVATE OPEN SPACE REQUIREMENT. HOW IS THIS BEING
 MET? PLEASE PROVIDE OPEN SPACE TYPE AND HOW IT MEETS
 THE STANDARDS OF THAT TYPE. SEE. TABLE IV-6 AND TABLE
 IV-7.
 - PLEASE PROVIDE STREETSCAPE LANDSCAPING DETAILS FOR N
 RAILROAD AVE. AND 7TH ST. FRONTAGES.
 RESPONSE: ACKNOWLEDGED. SEE SITE ANALYSIS EXHIBIT
 PROVIDED HEREIN.
 2. ZONING REVIEW 5.1.23 ??? [NOT SATISFIED]
 PER SEC. 94-109 ??? OPEN SPACE, PRIVATE; IF PRIVATE
 OPEN SPACE IS LOCATED ON THE GROUND FLOOR AND LOCATED
 ALONG THE LOT FRONTAGE, IT SHALL BE DESIGNED IN
 COMPLIANCE WITH THE PUBLIC OPEN SPACE REQUIREMENTS, AND
 IT SHALL BE ACCESSIBLE BY THE PUBLIC FOR PUBLIC USE.
 PLEASE PROVIDE CLARIFICATION AND IDENTIFY ON SITE PLAN
 & LP-1 WHAT TYPOLOGY OF PUBLIC OPEN SPACE IS BEING
 PROVIDED PER SEC. 94-109 TABLE IV-6 AND TABLE IV-7
 (I.E. PASSAGEWAY, GARDEN PLAZA, AND GARDEN COURTYARD);
 PLEASE BE SURE TO MEET THE STANDARDS OF TABLE IV-7 FOR
 THE SELECTED CLASSIFICATION. PLEASE REVISE SITE
 ANALYSIS EXHIBITS SHEET AND LP-1 ACCORDINGLY.
 MAX OVERHEAD COVER IS A PERCENTAGE; USUALLY 20% PLEASE
 CLARIFY HOW MUCH OF THIS SPACE IS BEING COVERED BY
 ROOFS OR OVERHEAD STRUCTURES.
  
 3. TRANSPARENCY REQUIREMENTS - PLEASE PROVIDE
 TRANSPARENCY CALCULATIONS; 50% ON N RAILROAD AND 50% ON
 7TH
 RESPONSE: ACKNOWLEDGED. SEE SITE ANALYSIS EXHIBIT
 PROVIDED HEREIN.
 3. ZONING REVIEW 5.1.23 ??? [PARTIALLY SATISFIED]
 TRANSPARENCY CALCULATIONS APPEAR TO BE MET, PLEASE
 PROVIDE MARKUP OF FIRST FLOOR ELEVATION THAT DIMENSIONS
 THE BUILDING FRONTAGE AND FENESTRATION/TRANSPARENCY
 (PLEASE REFERENCE SEC. 94-109 FIGURE IV-33) ONLY THE
 ACTIVE USES AND FIRST 10FT. OF HEIGHT FROM SIDEWALK
 ELEVATION NEEDS TO BE CALCULATED.
  
  
 4. SITE PLAN MENTIONS PARKING REQUIREMENTS BEING MET
 WITH VALET SERVICE OFFSITE, PLEASE INDICATE WHERE THE
 OFF-SITE PARKING IS LOCATED. - IS ALL OF THE PARKING
 UNDER A VALET SERVICE?
 RESPONSE: PARKING SHALL BE PROVIDED WITHIN THE CENTRAL
 PARKING LOT; ON-STREET AND WITHIN THE TEMPORARY PARKING
 LOT LOCATED AT THE NORTH END OF THE PROJECT. EACH
 TENANT OR BUILDING WILL COORDINATE VALET PARKING
 SERVICES FOR THEIR RESPECTIVE CUSTOMERS.
 4. ZONING REVIEW 5.1.23 ??? [SATISFIED] OFFSITE PARKING
 TO GO BEFORE DAC
  
 5. WHERE IS THE GARBAGE ENCLOSURE LOCATED? DETAIL IS
 SHOWN ON SITE PLAN, BUT NO LOCATION INDICATED. PLEASE
 CLARIFY LOCATION AND OPERATION.
 RESPONSE: THE DUMPSTER DETAIL HAS BEEN REMOVED FROM
 THE PLAN. A TRASH ROOM THAT WILL ACCOMMODATE GARBAGE;
 RECYCLING AND BULK PICK UP ITEMS HAD BEEN FURNISHED AT
 THE NORTH END OF THE BUILDING ACCESSING THE ALLEY.
 5. ZONING REVIEW 5.1.23 ??? [SATISFIED] ARE THE CANS TO
 BE ROLLED OUT TO THE ALLEY? BE SURE SANITATION IS OKAY
 WITH PROPOSAL.
  
 6. WHERE IS THE LOADING OPERATION LOCATED? DETAIL IS
 SHOWN ON SITE PLAN, BUT NO LOCATION INDICATED. PLEASE
 CLARIFY LOCATION AND OPERATION.
 RESPONSE: ACKNOWLEDGED. THE SITE WILL BE ACCESSED FROM
 THE PUBLIC ALLEY FOR LOADING/UNLOADING AND TRASH
 REMOVAL. SEE UPDATED SITE PLAN INDICATING THE LOCATION
 OF THE SERVICE AREA OF THE BUILDING AND TRASH ROOM
 ACCORDINGLY.
 6. ZONING REVIEW 5.1.23 ??? [SATISFIED]
  
 7. PHOTOMETRIC ANALYSIS SHOWS SOUTHEASTERN CORNER OF
 PROPERTY ALONG 7TH STREET WITH AREAS BELOW REQUIRED 0.6
 FOOTCANDLES.
 RESPONSE: SEE UPDATED PHOTOMETRIC PLAN FOR
 MODIFICATIONS TO THE AREAS OF THE PLAN NOT IN
 COMPLIANCE WITH THE 0.6 FOOTCANDLE REQUIREMENT.
 7. ZONING REVIEW 5.1.23 ??? [NOT SATISFIED]
 PHOTOMETRICS STILL SHOW AREAS AT 0.5 AT SOUTHEAST END
 OF PROPERTY.
  
 8. PLEASE INDICATE WHERE REQUIRED BIKE PARKING SPACES
 ARE LOCATED.
  
 RESPONSE: BICYCLE PARKING EXISTS WITHIN THE R-O-W (UP
 TO THREE BIKE RACKS ARE PROVIDED) IN CLOSE PROXIMITY TO
 THE PUBLIC ENTRANCE TO THE SITE. SEE UPDATED SITE PLAN
 AND ASSOCIATED STREETSCAPE PLAN.
 8. ZONING REVIEW 5.1.23 ??? [SATISFIED] BIKE PARKING
 FACILITATED IN ROW; REQUIREMENT FOR THE TABLE IS 1
 SPACE FOR EVERY 100??? OF FRONTAGE; THEREFORE 2 SPACES
 REQUIRED. THOSE ARE IN ROW.
  
 9. RENDERING SHOWS NORA NEIGHBORHOOD SIGNAGE ONSITE,
 PLEASE NOTE ANY SIGNAGE WILL BE UNDER A SEPARATE
 PERMIT.
 RESPONSE: ACKNOWLEDGED
 9. ZONING REVIEW 5.1.23 ??? [SATISFIED]
  
  
 NEW ZONING COMMENTS 5.1.23:
 1. PLEASE PROVIDE PROJECTION DETAILS OR DIMENSIONS FOR
 THE CANOPY ELEMENTS SHOWN ON THE ELEVATIONS. BE SURE
 THAT THESE ELEMENTS MEET THE STANDARDS IN SEC. 94-109
 TABLE IV-5. ELEVATIONS PROVIDED, PLEASE SHOW
 PROJECTIONS.
  
 2. ANY ROOFTOP MECHANICAL EQUIPMENT SHALL BE SCREENED
 FROM VIEW. PER SEC. 94-109 PROJECTION, VERTICAL:
 MECHANICAL EQUIPMENT AND APPURTENANCES NECESSARY TO THE
 OPERATION OR MAINTENANCE OF THE BUILDING OR STRUCTURE
 ITSELF SUCH AS, BUT NOT LIMITED TO, COOLING TOWERS,
 ELEVATORS, STAIRS AND MECHANICAL PENTHOUSES, VENT
 STACKS AND ANTENNAS SHALL BE ENCLOSED AND SCREENED IN
 SUCH A MANNER THAT THE ENCLOSURE IS DESIGNED AS AN
 INTEGRAL PART OF THE OVERALL BUILDING DESIGN.
  
 3. MECHANICAL EQUIPMENT ON THE GROUND CAN ENCROACH INTO
 SETBACKS A MAXIMUM OF 4FT MUST LEAVE AT LEAST 1FT. BE
 SURE THAT THE MECHANICAL EQUIPMENT MEETS THIS
 ENCROACHMENT STANDARD.
  
  
 CHRIS KIMMERLY, AICP
 URBAN DESIGN PLANNER
 822.1426 [email protected]
  