| Date |
Text |
| 2023-02-01 10:11:41 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, |
| | COMMENTS: |
| | |
| | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE |
| | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH |
| | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE |
| | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. COMMENTS |
| | 2 THROUGH 5 MUST BE ADDRESSED FOR SITE PLAN APPROVAL. |
| | |
| | 2. UNITY OF TITLE. FOR ANY BUILDING CROSSING A PROPERTY |
| | LINE, EITHER A RECORDED UNITY OF TITLE, OR SOME OTHER |
| | APPROVED LEGAL INSTRUMENT, SHALL BE INCLUDED WITH THE |
| | PERMIT APPLICATION, OR THE BUILDING MUST HAVE A FIRE |
| | WALL ALONG THE PROPERTY LINE, PER SECTION 202 OF |
| | FLORIDA BUILDING CODE, BUILDING, FIRE SEPARATION |
| | DISTANCE. |
| | |
| | 3. COMMENT ADDRESSED. NO FURTHER ACTION REQUIRED. |
| | WHEELCHAIR ACCESS TO POOL DECK. THE POOL DECK IS |
| | ACCESSED VIA STAIRS. THE ELEVATOR THE SERVES THE POOL |
| | DECK DOES NOT HAVE ACCESS FROM THE 1ST FLOOR. 1ST FLOOR |
| | PLAN, SHEET A2.0, SHOWS THAT ELEVATOR ACCESSING THE |
| | LOADING AREA ONLY. |
| | |
| | 4. VAN ACCESSIBLE PARKING SPACES. COMMENT NOT |
| | ADDRESSED. THE PARKING DATA TABLE ON SITE DATE SHEET |
| | A0.1 STATES THAT 9 ACCESSIBLE PARKING SPACES WILL BE |
| | PROVIDED, BUT THAT TABLE AND THE FLOOR PLANS SHOW ONLY |
| | ONE OF THOSE SPACES TO BE VAN ACCESSIBLE. AT LEAST 2 |
| | VAN ACCESSIBLE PARKING SPACES ARE REQUIRED. PER SECTION |
| | 208.2.4 OF FLORIDA ACCESSIBILITY CODE, ONE IN EVERY SIX |
| | REQUIRED ACCESSIBLE SPACES (AT LEAST ONE) IN A PARKING |
| | STRUCTURE, SHALL BE VAN ACCESSIBLE AND DESIGNED IN |
| | ACCORDANCE WITH SECTION OF 502 OF FLORIDA ACCESSIBILITY |
| | CODE (VERTICAL CLEARANCE NOT LESS THAN 98 INCHES AT |
| | SPACE AND VEHICULAR ACCESS ROUTE) |
| | |
| | 5. ELECTRIC VEHICLE CHARGING STATION. COMMENT NOT |
| | ADDRESSED. THE FIRST FLOOR PLAN SHOWS 4 EV PARKING |
| | SPACES. IF ELECTRIC VEHICLE (EV) CHARGING STATIONS ARE |
| | PROVIDED AT LEAST 1 IN 25 MUST COMPLY WITH ACCESSIBLE |
| | PARKING SPACE REQUIREMENTS. EITHER PROVIDE A CHARGING |
| | STATION AT ONE OF THE ACCESSIBLE PARKING SPACES, OR |
| | MAKE ONE OF THE EV CHARGING STATIONS COMPLY WITH |
| | ACCESSIBLE PARKING SPACE SIZE, ACCESS, AND SIGNAGE |
| | REQUIREMENTS. |
| | |
| | 6. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT, |
| | THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR |
| | THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT, |
| | AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE |
| | FLORIDA BUILDING CODE. |
| | |
| | 7. BUILDING LOCATION RELATIVE TO THE PROPERTY LINE AND |
| | OTHER STRUCTURES. WHEN SUBMITTED FOR BUILDING PERMIT, |
| | COMPLIANCE WITH ALL BUILDING SEPARATION, PERCENTAGE OF |
| | OPENINGS AND OPENING PROTECTIVE REQUIREMENTS OF |
| | CHAPTERS 6 AND 7 OF THE FLORIDA BUILDING CODE SHALL BE |
| | VERIFIED. |
| | |
| | 8. ENCLOSED PARKING GARAGES. IF THE PARKING GARAGE DOES |
| | NOT HAVE WALL OPENINGS, OR SUFFICIENT WALL OPENINGS TO |
| | MEET THE DEFINITION OF AN OPEN PARKING GARAGE, IT WILL |
| | BE CONSIDERED AN ENCLOSED PARKING GARAGE AND MUST HAVE |
| | EXHAUST SYSTEMS. THE EXHAUST SYSTEMS SHALL BE DESIGNED |
| | TO MINIMIZE NOISE LEVELS USING INLINE FAN SILENCERS OR |
| | OTHER APPROVED METHODS. |
| | |
| | 9. GREASE INTERCEPTOR. IF THE RETAIL SPACE IS TO BE A |
| | REATAURANT A GREASE INTERCEPTOR WILL BE REQUIRED. FOR |
| | INFORMATION ON THE REQUIRED TYPE, SIZE AND LOCATION, |
| | PLEASE CONTACT RYAN BROWN, CHIEF PLUMBING INSPECTOR, |
| | DEVELOPMENT SERVICES DEPARTMENT, AT (561) 805-6692, OR |
| | BY EMAIL: [email protected] |
| | |
| | 10. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS |
| | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE |
| | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED |
| | FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS, |
| | GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND |
| | OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS, |
| | SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC. |
| | |
| | 11. CONTRACTOR VEHICLE PARKING. PROPERTY OWNER AND |
| | CONTRACTOR SHALL MAKE ARRANGEMENTS FOR PARKING OF |
| | CONTRACTOR VEHICLES TO MINIMIZE THE IMPACT ON ALL |
| | NEIGHBORING PROPERTIES. |
| | |
| | 12. PROTECTION OF NEIGHBORING PROPERTY. PROPERTY OWNER |
| | AND CONTRACTOR SHALL PROTECT ALL NEIGHBORING PROPERTY, |
| | INCLUDING VEHICLES, FROM DAMAGE OR DIRT CAUSED BY THE |
| | CONSTRUCTION, AND SHALL NOTIFY THE OCCUPANTS OF |
| | NEIGHBORING PROPERTIES ABOUT ALL STAGES OF CONSTRUCTION |
| | THAT MAY AFFECT THE USE OF THEIR PROPERTY. |
| | |
| | 13. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT |
| | WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL |
| | HAVE A SEPARATE ADDRESS ASSIGNED BASED ON THE LOCATION |
| | OF THE BUILDING ENTRANCE. FOR STREET ADDRESSING, |
| | CONTACT CAROLINE PUELL, ADDRESSING COORDINATOR, AT |
| | (561) 805 6659, OR BY EMAIL: [email protected] |
| | |
| | ROBERT BROWN |
| | BUILDING OFFICIAL |
| | TEL: 561 805 6652 |
| | EMAIL: [email protected] |
| | |
| |
Print |