| Date |
Text |
| 2022-07-08 13:39:47 | TRAFFIC COMMENTS |
| | 1) PROVIDE COUNTY TPS LETTER |
| | 2) A METHODOLOGY MEETING SHOULD BE SCHEDULED WITH THE |
| | CITY'S TRANSPORTATION GROUP |
| | 3) PROVIDE A REVISED TRAFFIC STUDY INCLUSIVE OF THE |
| | RESIDENTIAL PORTION OF THE PROPOSED DEVELOPMENT |
| | |
| | SITE COMMENTS |
| | 4) PROVIDE A CLEAN SITE PLAN SHOWCASING ALL |
| | TRANSPORTATION FEATURES (E.G. ROADWAY, DRIVING AISLES, |
| | PARKING STALLS, SIDEWALK, CURB, DRIVEWAY, GATES, |
| | SIGNAGE, PAVEMENT MARKINGS, ETC.) PROPERLY LABELED AND |
| | DIMENSIONED. |
| | 5) IN THE TRANSPORTATION SITE PLAN, PLEASE SHOWCASE |
| | BASIC CURB DETAILS (I.E. DRIVEWAY, CURB CUTS, AND |
| | PARKING STALLS) ON THE OPPOSITE SIDE OF THE ROADS |
| | SURROUNDING THE PROPOSED DEVELOPMENT |
| | 6) PROVIDE AUTOTURN ANALYSIS FOR GARBAGE TRUCK AND/OR |
| | SERVICE VEHICLES DRIVING IN AND OUT OF THE PROPOSED |
| | DEVELOPMENT WITH VEHICLE DYNAMIC ENVELOPES CLEARLY |
| | DEFINED. ANALYSIS SHOULD BE PROVIDED IN A SEPARATE |
| | FILE/DRAWING FOR EACH VEHICLE PARKING MANEUVERS. |
| | ANALYSIS PRESENTED IN A1.01 IS NOT PROPER NOR |
| | ACCEPTABLE |
| | 7) IDENTIFY AND DESIGNATE AN EASILY ACCESSIBLE |
| | MICRO-MOBILITY STATION AREA (MINIMUM 8 X 20 FEET) AND |
| | PROVIDE BASIC ELECTRIFICATION READINESS. MORE SPECIFICS |
| | ON THE ELECTRIFICATION: A CONDUIT (2" SCHEDULE 40 PVC) |
| | TO THE POWER SOURCE WITH AN ELECTRICAL PULL BOX (240V |
| | 10,000W CIRCUIT). PLEASE PROVIDE DOCUMENT NAME AND |
| | SHEET NUMBER SHOWCASING SUCH FEATURE |
| | 8) PROVIDE PARKING TABLE SHOWCASING THE NUMBER OF |
| | REQUIRED AND PROVIDED PARKING SPACES, INCLUSIVE OF ADA |
| | AND BICYCLE ONES. IF ALREADY PROVIDED, PLEASE INDICATE |
| | SHEET NAME/NUMBER |
| | 9) PER CITY CODE 94-312(4)(C): ACCESS TO ALL |
| | RESIDENTIAL LOTS IN A PROPOSED SUBDIVISION SHALL BE |
| | PROVIDED FROM THE LOWEST FUNCTIONAL CLASS OF ROADWAY |
| | HAVING FRONTAGE ON THE LOT. THUS, THE DRIVEWAY UNTO S |
| | DIXIE HIGHWAY WILL NOT BE ALLOWED, AS BOTH FERN ST AND |
| | GARDENIA ST CAN ACCOMMODATE ANY ACCESS NEEDS |
| | 10) EXPLAIN THE REASONING OR NECESSITY OF TWO EXIT |
| | LANES AND ONE ENTRY LANE AT THE FERN ST DRIVEWAY. |
| | MAXIMUM ALLOWED DRIVEWAY WIDTH IS 25 FEET |
| | 11) EXPLAIN THE USE OF THE PARKING AREA ON DIXIE |
| | 12) PROVIDE GARAGE RAMPS SLOPES |
| | 13) CLEARLY MARK/CALLOUT THE TURNAROUND SPACES AT THE |
| | GARAGE DEAD-ENDS |
| | 14) COORDINATE WITH PARKING DEPARTMENT THE REMOVAL OF |
| | METERED SPACES |
| | |
| | VALERIO ORICCHIO |
| | CITY TRANSPORTATION ENGINEER |
| | 561-494-1092 |
| | [email protected] |
| | |
| |
Print |