2022-07-05 13:35:351. SURVEY, PLANS AND ACREAGE NEED TO BE REVISED TO
 REFLECT PREVIOUS ACQUISITION BY CITY AND FDOT
 MAINTENANCE MAPS. AREAS ARE NOT CLAIMED BUT ARE VESTED
 IN THE CITY PER STATE STATUTE 95.361.
 2. EXPLAIN HOW EXISTING BUILDING IS TO RETAIN OWNERSHIP
 WHEN PROPERTY IS RE-PLATTED(REQUIRED). WILL THIS BE A
 SEPARATE PARCEL?
 3. FDOT APPROVAL OF ENTRANCE AND PERMIT FOR UTILITIES
 WILL BE REQUIRED.
 4. FPL CONDUIT WILL REQUIRE SEPARATE R/W PERMIT.
 CABINET PME-9 NEEDS TO BE OUTSIDE OF MAINTENANCE R/W.
 5. METERS AND BACKFLOWS OFF OF DIXIE NEED TO BE OUTSIDE
 OF R/W.
 6. EXISTING SERVICES TO BE CUT BACK TO MAIN.
 7. SHOW ALL PROPOSED UTILITIES ON LANDSCAPE PLANS.
 8. NEED EXISTING ELEVATIONS ON ALL ROADWAYS AND
 PROPOSED F.F. ELEVATIONS.
 9. DOORWAYS CANNOT OPEN INTO RIGHT-OF-WAY OR AREAS
 PROPOSED FOR PEDESTRIAN ACCESS EASEMENTS.
  
  
 ADDITIONAL COMMENTS WILL BE FORTHCOMING AFTER REVISED
 SUBMITTAL.