| Date |
Text |
| 2022-07-28 08:42:09 | TRAFFIC COMMENTS |
| | 1) SATISFIED. GIVEN THE SENSITIVE LOCATION OF THE |
| | PROPOSED DEVELOPMENT, A METHODOLOGY MEETING SHALL BE |
| | SCHEDULED FOR A COMPREHENSIVE TRAFFIC STUDY |
| | 2) SATISFIED. PROVIDE A THOROUGH VALET SERVICE/QUEUE |
| | ANALYSIS |
| | 3) PARTIALLY SATISFIED. PROVIDE COUNTY TPS LETTER, ONCE |
| | RECEIVED |
| | 4) PARTIALLY SATISFIED. PROVIDE FDOT D4 ACCESS |
| | MANAGEMENT LETTER, ONCE RECEIVED |
| | |
| | SITE COMMENTS |
| | 5) NOT SATISFIED. ON THE SITE PLAN, PLEASE SHOWCASE |
| | BASIC CURB DETAILS (I.E. DRIVEWAY AND PARKING STALLS) |
| | ON THE OPPOSITE SIDE OF THE ROADS SURROUNDING THE |
| | PROPOSED DEVELOPMENT. PLEASE PROVIDE DOCUMENT NAME AND |
| | SHEET NUMBER SHOWCASING SUCH FEATURES. REQUEST IS FOR A |
| | CLEAN SITE PLAN, SHOWCASING AND HIGHLIGHTING |
| | TRANSPORTATION ELEMENTS (E.G. NO UNDERGROUND UTILITY |
| | DETAILS, ONLY SURFACE ITEMS SUCH AS POLES AND BASINS). |
| | ALSO, NONE OF THE CIVIL OR ARCHITECTURAL PLANS ARE |
| | SHOWCASING PAVEMENTS MARKINGS AND LANE WIDTHS OF THE |
| | SURROUNDING ROADWAY NETWORK. PLEASE PROVIDE A DEDICATED |
| | AND DETAILED TRANSPORTATION-ORIENTED SITE PLAN. |
| | 6) SATISFIED. SHEET C-102, RIGHT DRAWING. WB-40 |
| | MANEUVERING SHOWS ENCROACHMENT WITH THE INTERNAL |
| | SIDEWALK BY THE DROP-OFF AREA. IS THAT PORTION OF THE |
| | WALKWAY CURB LESS? |
| | 7) SATISFIED. SHEET A1.04 TO 06, PROVIDE AND CLEARLY |
| | MARK TURNAROUND SPACE AT THE SOUTHERN DEAD-END |
| | 8) SATISFIED. SHEET A1.07, PROVIDE AND CLEARLY MARK |
| | TURNAROUND SPACE AT THE SOUTHERN AND NORTHERN DEAD-ENDS |
| | 9) SATISFIED. IDENTIFY AND DESIGNATE AN EASILY |
| | ACCESSIBLE MICRO-MOBILITY STATION AREA (MINIMUM 8 X 20 |
| | FEET) AND PROVIDE BASIC ELECTRIFICATION READINESS. FOR |
| | THE LATTER ITEM, MORE SPECIFICALLY: A CONDUIT (2? |
| | SCHEDULE 40 PVC) TO THE POWER SOURCE WITH AN ELECTRICAL |
| | PULL BOX (240V 10,000W CIRCUIT). PLEASE PROVIDE |
| | DOCUMENT NAME AND SHEET NUMBER SHOWCASING SUCH FEATURE. |
| | 10) SATISFIED. PROVIDE NUMBER AND LOCATION OF BICYCLE |
| | PARKING |
| | 11) SATISFIED. A MINIMUM OF 2 ADA VAN ACCESSIBLE |
| | PARKING SPACES MUST BE PROVIDED, PLEASE INDICATE THOSE |
| | STALLS |
| | 12) NOT SATISFIED. PROVIDE 10 FEET WIDE SIDEWALKS |
| | AROUND THE PROPOSED DEVELOPMENT. THIS ITEM WILL BE |
| | REVIEWED AND CLEARED ONCE A TRANSPORTATION SPECIFIC |
| | SITE PLAN IS PROVIDED. |
| | 13) SATISFIED. REMOVE THE PARALLEL PARKING STALLS ON |
| | DIXIE |
| | 14) PARTIALLY SATISFIED. MAKE THE NORTHERN DRIVEWAY ON |
| | LAKEVIEW AVE EXIT ONLY. PROVIDE A TRAFFIC ANALYSIS |
| | QUANTIFYING THE INCREASE IN TRAFFIC, IF ANY. DRIVEWAY |
| | CONFIGURATION OF NEARBY BUILDINGS IS NOT A SUFFICIENT |
| | JUSTIFICATION. |
| | 15) PARTIALLY SATISFIED CONSIDER MAKING THE SOUTHERN |
| | DRIVEWAY ON OKEECHOBEE BLVD ENTRY ONLY. PROVIDE A |
| | TRAFFIC. ANALYSIS QUANTIFYING THE INCREASE IN TRAFFIC. |
| | PROVIDE A TRAFFIC ANALYSIS QUANTIFYING THE INCREASE IN |
| | TRAFFIC, IF ANY. DRIVEWAY CONFIGURATION OF NEARBY |
| | BUILDINGS IS NOT A SUFFICIENT JUSTIFICATION. |
| | |
| | VALERIO ORICCHIO |
| | CITY TRANSPORTATION ENGINEER |
| | 561-494-1092 |
| | [email protected] |
| | |
| |
Print |