2022-06-16 16:18:481) NOT SATISFIED. PROVIDE COUNTY TPS LETTER
 2) SATISFIED. PROVIDE A MINIMUM 3' LONG
 TURNAROUND/MANEUVERING AREA AT THE DEAD-END/EAST-SIDE
 OF THE NORTHERN PARKING LOT. REMOVE THE LAST PARKING
 STALL ON THE NORTH-EAST CORNER IF NECESSARY AND MARK IT
 AS TURNAROUND ZONE.
 3) SATISFIED. MAXIMUM ALLOWED DRIVEWAY WIDTH IS 25?.
 TWO-WAY DRIVEWAY GREATER THAN 25 FEET COULD BE PROVIDED
 ONLY WHEN ABSOLUTELY NECESSARY AND JUSTIFIED WITH
 AUTOTURN, IN WHICH CASE DIAGONAL HATCHING SHOULD BE
 USED TO DELINEATE DRIVEWAY LANES FOR PASSENGER CARS.
 4) NOT SATISFIED. THE EASTERLY DRIVEWAY MUST BE CLOSED,
 AS THE PROPOSED DEVELOPMENT WOULD REQUIRE VEHICLES
 BACKING OUT TO PUBLIC ROW IN ORDER TO EXIT. PER CITY
 CODE SEC. 94-485(M): ?ALL VEHICULAR MOVEMENT AND
 MANEUVERING THAT MAY BE REQUIRED TO UTILIZE OFF-STREET
 PARKING FACILITIES SHALL BE RETAINED ON-SITE. PUBLIC
 RIGHTS-OF-WAY SHALL NOT BE UTILIZED TO ALLOW OR ENHANCE
 MOVEMENT OR MANEUVERING EXCEPT FOR THOSE USES WITHIN
 THE DOWNTOWN MASTER PLAN AREA PURSUANT TO SUBSECTION
 94-102(W)
 5) SHOW ON THE SITE PLAN AND INSTALL STOP SIGN AND STOP
 BAR AT THE ACCESS DRIVEWAY
  
 VALERIO ORICCHIO
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]
  