Plan Review Notes
Plan Review Notes For Project Z22040056
Project Number Z22040056
Review Stop TRAFFIC
Sequence Number 2
Notes
Date Text
2022-08-02 10:31:061) SATISFIED. GIVEN THE CHANGE TO ROADWAY GEOMETRY, USE
 TYPE FOR SOME OF THE PROPOSED FACILITIES, AND
 CORRESPONDING TRIP GENERATION, PROVIDE A REVISED
 TRAFFIC STUDY
 2) PARTIALLY SATISFIED. PROVIDE COUNTY TPS LETTER. PALM
 BEACH COUNTY NEEDS TO UPDATE THE GIS DATABASE PER THE
 CHANGE IN TRIP GENERATION, INDEPENDENTLY IF THERE IS AN
 INCREASE OR DECREASE. EITHER OBTAIN A NEW TPS LETTER OR
 PROVIDE PROOF OF COMMUNICATION AND ACKNOWLEDGEMENT FROM
 THE COUNTY.
 3) SATISFIED. PROVIDE FDOT ACCESS LETTER
 4) SATISFIED. PROVIDE WIDTH OF EACH DRIVEWAY AT THE
 SIDEWALK INTERFACE.
 5) PARTIALLY SATISFIED. PROVIDE PAVEMENT MARKINGS
 AND/OR EXPLAIN OPERATIONS AT THE MODIFIED HOTEL
 DROP-OFF. INTEGRATE PAVEMENT MARKINGS INFORMATION IN
 THE TRANSPORTATION SPECIFIC SITE PLAN
 6) SATISFIED. EXPLAIN THE USE FOR THE PROPOSED NEW
 DRIVING AREA BY THE QUADRILLE DRIVEWAY
 7) NOT SATISFIED. PROVIDE A SEPARATE SITE PLAN
 SHOWCASING BASIC TRANSPORTATION FEATURES AND THEIR
 DIMENSIONS, SUCH AS: SIDEWALK, CURB, PARKING STALLS,
 CROSSINGS, WALKWAY, ROADWAY, DRIVE ISLES, DRIVEWAYS,
 PAVEMENT MARKINGS, SIGNAGE, ETC. PROVIDE A
 TRANSPORTATION SPECIFIC SITE PLAN FOR THE GROUND FLOOR,
 SHEET A1.01 IS A GREAT STARTING POINT. PLEASE NAME IT
 T1.01
 8) SATISFIED. PROVIDE A MID-BLOCK PEDESTRIAN CROSSING
 ON 5TH ST. SPECIFICALLY AT THE WEST END OF THE NORTHERN
 SIDEWALK
 9) PARTIALLY SATISFIED. PROVIDE NARRATIVE PERTAINING
 THE MODIFICATIONS TO THE SOUTHERN PICK-UP/DROP-OFF
 AREA. AS THE PROPOSED DESIGN MAY HAVE SAFETY AND
 OPERATIONAL ISSUES. THE LATEST NARRATIVE IS NOT
 SUFFICIENT, PLEASE PROVIDE AN UPDATED PARKING
 MANAGEMENT PLAN PER COMMENT #14
 10) PER FDOT LETTER, THE QUADRILLE BLVD DRIVEWAY IS
 LEFT-IN, RIGHT-IN AND RIGHT-OUT ONLY. REVISE PAVEMENT
 MARKING(S) AND INSTALL CORRESPONDING SIGNAGE FOR THE
 EXIT MOVEMENT
 11) PER FDOT LETTER, SHOW THE 50 FEET MINIMUM DISTANCE
 FROM THE ULTIMATE RIGHT-OF-WAY LINE TO THE FIRST
 CONFLICT POINT AT THE QUADRILLE DRIVEWAY
 12) INSTALL RIGHT-TURN ONLY PAVEMENT MARKING(S) ALONG
 THE DECELERATION LANE TO THE QUADRILLE DRIVEWAY
 13) PEDESTRIAN CROSSWALK MARKINGS ACROSS THE QUADRILLE
 DRIVEWAY NEED TO BE PROPERLY ALIGNED, PLEASE CORRECT
 14) DUE TO THE SIGNIFICANT CHANGES IN USE TYPE, VALET
 PODIUM LOCATIONS, TRIP GENERATION AND CIRCULATION,
 PLEASE PROVIDE AN UPDATED PARKING MANAGEMENT PLAN
 15) IN THE UPDATED PARKING MANAGEMENT PLAN, PLEASE
 PROVIDE A DETAILED BREAKDOWN OF THE ASSUMED PROCESSING
 TIME IN THE QUEUE ANALYSIS (I.E. TIMINGS FOR VALET
 CHECK-IN/CHECK-OUT, VALET DRIVE/WALK TO/FROM THE
 GARAGE)
 16) SEVERAL DIMENSIONS OF THE VALET AREA ON 4TH ST ARE
 MISSING AS SHOWN IN A1.01. MOREOVER, THE FACILITY DOES
 NOT SEEM COMPLIANT WITH SEC 94-109 FIGURE IV-22. PLEASE
 PROVIDE DIMENSIONS AND REQUEST VARIANCE(S), IF ANY.
 17) GENERAL COMMENT: FOR ANY FEATURE OR SITE PLAN
 REFERENCE(S) IN EACH OF THE RESPONSE(S), THE SPECIFIC
 SHEET NAME AND NUMBER MUST BE PROVIDED. "REFER TO CIVIL
 DRAWINGS" IS NOT AN ACCEPTABLE RESPONSE
  
 VALERIO ORICCHIO
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]
  
  Print


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved