| Date |
Text |
| 2022-05-09 11:43:04 | Z22040056 - 550 QUADRILLE - MINOR AMEND? 1ST REVIEW |
| | |
| | COMMENTS FROM RICK ROSSANO, SR. PROJECT COORDINATOR, |
| | ENGINEERING SERVICES DEPARTMENT AT 561-494-1098 |
| | [email protected] |
| | O INDICATE HOW EXISTING AND PROPOSED INFRASTRUCTURE FOR |
| | THE ONE WEST PALM PROJECT MAY BE IMPACTED BY THE |
| | PROPOSED DROPOFF AND REVISIONS. |
| | O CLOUD PROPOSED REVISIONS AND DATE REVISED CIVIL |
| | SHEETS. |
| | |
| | |
| | COMMENTS FROM MARK HURLEY, CUST. SVC. SUPERVISOR, |
| | PUBLIC UTILITIES, [email protected], 561-822-2262: |
| | |
| | -ANY CHANGES MAY AFFECT E19010014. |
| | |
| | -ADD ABOVE GROUND WORDING TO 8 INCH METER LABELS. |
| | |
| | -RELOCATE TAP FOR EASTERN 8 INCH METER TO THE WEST NEAR |
| | THE METER, SO THAT EXTRANEOUS PIPE IS ELIMINATED. |
| | |
| | -ARE ANY GREASE TRAPS NEEDED AT 4TH ST.? |
| | |
| | -CLEARLY SHOW AND LABEL PROPERTY LINES ON CIVIL PLANS. |
| | |
| | -THERE IS A CLEANOUT IN FRONT OF A DOOR ON 4TH ST. |
| | MAINTENANCE MAY IMPEDE USE OF DOOR. |
| | |
| | -DROP MANHOLE MAY BE NEEDED AT MH2 ON 4TH ST. |
| | |
| | -PROPOSED SEWER POINT OF SERVICES NEED BE REVIEWED AT |
| | FORMAL ENGINEERING SUBMITTAL. |
| | |
| | -ON 4TH ST, LARGE DIAMETER WATER MAIN CROSSES IN CLOSE |
| | PROXIMITY OVER SANITARY PIPING. IS THAT VERTICAL LOAD |
| | ALRIGHT? |
| | |
| | -L1-121 DOES NOT MATCH LOCATIONS OF UTILITIES ON |
| | SUBMITTED CIVIL PLANS. PLEASE UPDATE L1-121 AND ENSURE |
| | NO CONFLICTS BETWEEN TREES AND WATER/SEWER UTILITIES. |
| | |
| | -VERIFY THAT WPB PARKS AND RECREATION DEPARTMENT AGREES |
| | WITH THE PLAN PROPOSAL FOR THEIR METERED WATER SERVICES |
| | NEAR THE SOUTHEAST AND NORTHWEST AREAS OF PROPERTY. |
| | |
| | -WATER METER ORDERING AND RECEIVING COULD TAKE UPWARDS |
| | OF FIVE MONTHS AFTER UTILITY QUOTES ARE PAID AND |
| | UTILITY BILLING ACCOUNTS ARE SETUP DUE TO THE SIZING. |
| | |
| |
Print |