2022-05-06 14:11:281) PROVIDE COUNTY TPS LETTER
 2) FIGURE 2 IN THE TRAFFIC STUDY IS INCORRECT. PER THE
 PROPOSED SITE PLAN, THE EASTERN DRIVEWAYS ALONG
 CONGRESS ARE EXIT ONLY. INBOUND TRAFFIC NEEDS TO BE
 REALLOCATED TO THE OKEECHOBEE DRIVEWAY
 3) PROVIDE WIDTH OF EACH ACCESS DRIVEWAY
 4) INSERT STOP BAR AND SIGNAGE AT THE NORTHERN DRIVEWAY
 5) STOP BAR MARKING AT THE EASTERN DRIVING AISLE BY THE
 SOUTHERN DRIVEWAY NEEDS TO BE RELOCATED FURTHER BACK
 6) PROVIDE AUTOTURN ANALYSIS FOR GARBAGE TRUCK AND/OR
 SERVICE VEHICLES DRIVING IN AND OUT OF THE PROPOSED
 DEVELOPMENT WITH VEHICLE DYNAMIC ENVELOPES CLEARLY
 DEFINED. ANALYSIS SHOULD BE PROVIDED IN A SEPARATE
 FILE/DRAWING. PLEASE PROVIDE DOCUMENT NAME AND SHEET
 NUMBER SHOWCASING THE ANALYSIS.
 7) REINSTALL DETECTABLE WARNING SURFACES AT THE NW
 CORNER OF THE CONGRESS AND OKEECHOBEE INTERSECTION
 8) PER CITY CODE SEC 94-485 TABLE XV-3, PROVIDE A
 MINIMUM OF 5 DISABLED SPACES
 9) PER CITY CODE, 1 BICYCLE EVERY 20 PARKING SPACES,
 GIVEN 123 SPACES, MINIMUM NUMBER OF BIKE RACKS IS 6
 10) INSTALL DO NOT ENTER SIGNS BY THE SOUTHERN-EAST
 DRIVEWAY
  