| Plan Review Notes For Project Z22040021 |
| Project Number |
Z22040021 |
|
| Review Stop |
STORM |
| Sequence Number |
3 |
|
| Notes |
| Date |
Text |
| 2023-02-07 20:06:57 | COMMENTS FROM THE REVIEW OF THE 12-2-2023, TO BE | | | ADDRESSED WITH THE ENGINEERING PERMIT SUBMITTAL: | | | | | | 1. PLANS APPEAR TO BE REDUCED IN SIZE SUCH THAT THE | | | SCALE BAR MEASURES 38.5 FEET WHEN THE 20-SCALE RULER IS | | | USED FOR MEASURING. SUBMIT PLANS WITH USABLE SCALE. | | | | | | 2. PARKING SPACE STRIPING DIMENSIONS SHOULD MATCH THE | | | ADA PARKING STALL DETAIL ON SHEET 7. SHEET 4 DIMENSIONS | | | THE PARKING STALL DEPTH AS 18 FEET. THE DETAIL ON SHEET | | | 7 SHOWS 19 FEET. | | | | | | 3. LIST THE VERTICAL DATUM REFERENCE AND CONVERSION | | | EQUATION TO NGVD1929 ON EVERY SHEET WITH ELEVATION | | | INFORMATION. | | | | | | 4. SHOW THE NEW CURB FOR THE BACK OF THE REMOVED | | | LANDSCAPE ISLAND ON THE PAVING AND GRADING PLAN. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 (O) | | | [email protected] | | | | | | |
| |