2023-02-07 20:06:57COMMENTS FROM THE REVIEW OF THE 12-2-2023, TO BE
 ADDRESSED WITH THE ENGINEERING PERMIT SUBMITTAL:
  
 1. PLANS APPEAR TO BE REDUCED IN SIZE SUCH THAT THE
 SCALE BAR MEASURES 38.5 FEET WHEN THE 20-SCALE RULER IS
 USED FOR MEASURING. SUBMIT PLANS WITH USABLE SCALE.
  
 2. PARKING SPACE STRIPING DIMENSIONS SHOULD MATCH THE
 ADA PARKING STALL DETAIL ON SHEET 7. SHEET 4 DIMENSIONS
 THE PARKING STALL DEPTH AS 18 FEET. THE DETAIL ON SHEET
 7 SHOWS 19 FEET.
  
 3. LIST THE VERTICAL DATUM REFERENCE AND CONVERSION
 EQUATION TO NGVD1929 ON EVERY SHEET WITH ELEVATION
 INFORMATION.
  
 4. SHOW THE NEW CURB FOR THE BACK OF THE REMOVED
 LANDSCAPE ISLAND ON THE PAVING AND GRADING PLAN.
  
 TRACY WARD, PE
 SENIOR STORMWATER ENGINEER
 ENGINEERING SERVICES DEPARTMENT
 561-494-1120 (O)
 [email protected]
  
  