Plan Review Notes
Plan Review Notes For Project Z22040015
Project Number Z22040015
Review Stop Z
Sequence Number 1
Notes
Date Text
2022-05-05 16:37:35GENERAL COMMENTS:
  
 1.) THE APPLICANT IS REQUESTING TO INCREASE THE
 DEVELOPMENT POTENTIAL ON THE SUBJECT PROPERTY FROM 0.75
 TO 1.5 F.A.R.. HAS THERE BEEN ANY PUBLIC OUTREACH
 WITHIN THE NEIGHBORHOOD? IT IS ADVISED THAT THE
 APPLICANT REACH OUT TO THE NEIGHBORING
 PROPERTIES/NEIGHBORHOOD ASSOCIATION(S) FOR PUBLIC INPUT
 ON THE PROPOSAL.
  
 2.) UPDATED SIGNED AND SEALED SURVEY IS REQUIRED.
 SURVEY PROVIDED IS NOT SIGNED AND SEALED AND IT IS OVER
 2 YEARS OLD. THE PROVIDED SURVEY IS NOT ACCEPTABLE.
 PLEASE REFER TO PAGE 5 OF THE 2022 DEVELOPMENT
 APPLICATION FOR THE MINIMUM REQUIREMENTS ON THE SURVEY.
  
 3.) WHAT IS THE PURPOSE FOR THE PROPOSED FUTURE LAND
 USE (FLU) MAP AMENDMENT FROM COMMERCIAL (C) TO
 COMMERCIAL EAST (CE)? IS THERE A CONCEPTUAL PLAN AND/OR
 MASSING STUDY FOR THE SITE? DOES THE CONCEPTUAL/MASSING
 PLAN FIT WITH THE PROPOSED FLU CHANGE TO CE AND THE
 CONTEXT OF THE SURROUNDING AREA? CAN THE CONCEPTUAL
 PLAN MEET THE MINIMUM REQUIREMENTS OF THE ZONING AND
 LAND DEVELOPMENT REGULATIONS (ZLDRS)? ASIDE FROM THE
 CONTEXT OF THE SURROUNDING AREA, THE APPLICANT MUST BE
 ABLE TO PROVIDE MORE INFORMATION AND JUSTIFY WHY THE CE
 FLU IS DESIRED AND APPROPRIATE FOR THE SITE AND
 SURROUNDING AREA (I.E. THERE HAS TO BE A PURPOSE FOR
 THE FLUMA). A CONCEPTUAL SITE PLAN AND MASSING STUDY
 DEMONSTRATING THAT THE DESIGN/MAXIMUM MASSING OF THE OF
 THE SUBJECT PROPERTY CAN BE ACCOMMODATED AND FITS WITH
 THE CHARACTER AND CONTEXT OF THE SURROUNDING AREA WITH
 THE PROPOSED FLUMA SHOULD BE SUBMITTED TO SUPPLEMENT
 THE APPLICATION. THIS IS CRITICAL INFORMATION FOR STAFF
 TO ANALYZE IN DETERMINING IF THE FLUMA SHOULD BE
 SUPPORTED.
  
 4.) THE SUBJECT PROPERTY APPEARS TO HAVE A SPLIT FLU
 DESIGNATION OF CE AND C. THROUGH DATA AND ANALYSIS, THE
 APPLICANT MUST BE ABLE TO IDENTIFY HOW MUCH OF THE
 OVERALL 1.0-ACRE SUBJECT SITE (IN ACRES/SQUARE FEET) IS
 PROPOSED FOR THE FLU CHANGE TO CE. ONLY THE PORTION OF
 THE SITE THAT IS SUBJECT TO THE FLU MAP AMENDMENT WILL
 BE UTILIZED TO DETERMINE THE MAXIMUM DEVELOPMENT
 POTENTIAL AND ANALYZED FOR LEVEL-OF- SERVICE (LOS).
  
 5.) IN THE LOS ANALYSIS, THE MAXIMUM DEVELOPMENT
 POTENTIAL STATES THAT THE ACREAGE IS 0.6-ACRE. THERE IS
 NO EXPLANATION/BACK-UP INFORMATION/DOCUMENTATION TO
 WHERE THIS NUMBER CAME FROM (I.E. IT IS NOT MENTIONED
 IN THE JUSTIFICATION STATEMENT, NO SURVEY/ANALYSIS TO
 SHOW WHY 0.6-ACRE IS USED IN THE ANALYSIS FOR THE
 MAXIMUM DEVELOPMENT POTENTIAL, ETC.). PLEASE CLARIFY IN
 THE APPLICATION.
  
 6.) THE LOS CALCULATIONS/ANALYSIS IS BASED ON THE MOST
 INTENSIVE USE AND MOST INTENSIVE IMPACT (BASED ON THE
 MOST INTENSIVE USE) TO THE VARIOUS PUBLIC FACILITIES
 (I.E. IT COULD BE EITHER COMMERCIAL OR RESIDENTIAL).
 THE LOS ANALYSIS SHALL BE REVISED TO: A) CALCULATIONS
 MUST BE BASED ON THE MAXIMUM DEVELOPMENT POTENTIAL FOR
 ONLY THE AREA SUBJECT TO THE FLUMA. CHECK THE CITY'S
 COMPREHENSIVE PLAN FOR THE MAXIMUM DENSITY/INTENSITY
 FOR THE CE FLU (32.27 DU/ACRE OR 1.5 FAR). B) DATA AND
 LOS CALCULATIONS FOR EACH PUBLIC FACILITY MUST BE BASED
 ON THE MOST INTENSIVE USE/IMPACT GENERATED. C) FOR
 SANITARY SEWER: WHERE DID THE 0.20 GPD STANDARD COME
 FROM? CONTACT THE ENGINEERING SERVICES DEPARTMENT FOR
 RATE THAT SHOULD BE USED. D) FOR POTABLE WATER: WHERE
 DID THE 0.24 GPD STANDARD COME FROM? CONTACT THE
 ENGINEERING SERVICES DEPARTMENT FOR A RATE THAT SHOULD
 BE USED. E) FIGURE 1 PROVIDED IN THE LOS ANALYSIS
 DEPICTS THE WRONG PARCEL (I.E. IT IS NOT THE PARCEL
 LOCATED AT 319 BELVEDERE ROAD). PLEASE ADDRESS FOR
 CONSISTENCY. F) WHERE DID THE INFORMATION FROM
 ATTACHMENTS 1 AND 2 COME FROM? THE ANALYSIS DOES NOT
 REFERENCE WHERE THIS INFORMATION CAME FROM. G) THE LOS
 ANALYSIS SUMMARY TABLE AND SUMMARIES WILL NEED TO BE
 REVISED BASED ON THE CORRECTED INFORMATION.
  
 7.) THE PROPOSED FLU CHANGE IS EXPECTED TO INCREASE THE
 DEMAND ON PUBLIC FACILITIES. ANY INCREASE IN DEMAND ON
 ANY OF THE PUBLIC FACILITIES AS A RESULT OF THE
 PROPOSED FLU CHANGE SHALL ALSO PROVIDE WRITTEN
 CONFIRMATION FROM THE APPLICABLE SERVICE AGENCY
 INDICATING THAT SUFFICIENT CAPACITY/RESERVE CAPACITY
 EXISTS TO ACCOMMODATE THE BUILD-OUT OF THE PROPOSED FLU
 DESIGNATION. CERTIFICATION LETTERS WILL BE REQUIRED FOR
 THE FOLLOWING: DRAINAGE, WATER, WASTEWATER (SEWER)
 SOLID WASTE, SCHOOLS AND TRAFFIC. PLEASE NOTE THAT A
 GENERAL STATEMENT STATING THAT THE CITY HAS SUFFICIENT
 CAPACITY AVAILABLE FOR THE FLUMA IS INSUFFICIENT (AS
 NOT ALL SERVICES ARE PROVIDED BY THE CITY AND CAPACITY
 MUST BE VERIFIED BY THE VARIOUS SERVICE PROVIDERS.).
  
 8.) THE JUSTIFICATION STATEMENT MUST BE CLEAR ON THE
 REQUEST. PLEASE REVISE THE JUSTIFICATION STATEMENT TO
 SPECIFY/EXPAND ON THE RELATED BACKGROUND INFORMATION ON
 THE PROJECT SITE; JUSTIFICATION, SPECIAL REASONS, OR
 BASIS FOR THE REQUEST; VISION/CONCEPTUAL PROPOSED FOR
 THE SUBJECT SITE AND MASSING STUDY; AMOUNT OF AREA OF
 THE OVERALL PARCEL SUBJECT TO THE FLUMA, ETC.
  
  
  
 INSTRUCTIONS FOR RESUBMITTAL:
  
 * PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 * WHEN RESUBMITTING, PLEASE PROVIDE TWO (2) PAPER
 COPIES AND AN ELECTRONIC COPY OF ALL PLANS/DOCUMENTS IN
 THE RESUBMITTAL. PLEASE NOTE THAT CHANGES ON THE
 RESUBMITTED PLANS MAY RESULT IN ADDITIONAL COMMENTS.
  
 * YOU WILL BE PERMITTED ONE (1) RESUBMITTAL AT NO
 ADDITIONAL COST. IF PREVIOUSLY-ISSUED COMMENTS CONTINUE
 TO NOT BE SUFFICIENTLY ADDRESSED, THE APPLICANT WILL BE
 ASSESSED A RESUBMITTAL FEE. SUCH FEE WILL BE 20 PERCENT
 OF THE ORIGINAL APPLICATION FEE ($600.00).
  