Plan Review Notes
Plan Review Notes For Project Z22040014
Project Number Z22040014
Review Stop B
Sequence Number 2
Notes
Date Text
2022-07-19 16:12:31DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION,
 COMMENTS:
  
 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE
 SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH
 FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE
 ADDRESSED FOR THE BUILDING PERMIT APPLICATION.
  
 2. NUMBER OF ACCESSIBLE PARKING SPACES. INFORMATIONAL
 COMMENT. THE PARKING DATA IS NOW SHOWN IN THE VEHICULAR
 PARKING TABLE ON SHEET A0-02. PLEASE NOTE THAT THE
 REQUIRED NUMBER OF VAN ACCESSIBLE PARKING SPACES CAN BE
 PART OF THE TOTAL NUMBER OF ACCESSIBLE SPACES. IT IS
 NOT NECESSARY FOR THE VAN ACCESSIBLE PARKING SPACES TO
 BE IN ADDITION TO THE ACCESSIBLE PARKING SPACES. THE
 MINIMUM NUMBER OF ACCESSIBLE PARKING SPACES PROVIDED
 SHALL BE IN ACCORDANCE WITH FAIR HOUSING ACT AND
 SECTION 208.2 OF FLORIDA ACCESSIBILITY CODE.
  
 3. LOCATION OF ACCESSIBLE PARKING SPACES. NOW ALL OF
 THE ACCESSIBLE PARKING SPACES ARE NOW SHOWN CLOSE TO
 THE RESIDENTIAL TOWERS, AND NONE OF THE ACCESSIBLE
 PARKING SPACES ARE SHOW AS THE CLOSEST PARKING SPACES
 TO THE SOUTH OFFICE/HOTEL/RETAIL BUILDING. THERE ARE
 DOZENS OF REGULAR PARKING SPACES SHOWN CLOSER TO THE
 PARKING GARAGE SOUTH ELEVATOR THAN THE DISTANCE FROM
 THE CLOSEST ACCESSIBLE PARKING SPACE TO THAT ELEVATOR.
 THE ACCESSIBLE PARKING SPACES MUST BE DISTRIBUTED SO
 THAT SOME OF THEM ARE THE CLOSEST PARKING SPACES TO THE
 VARIOUS RETAIL SPACES. PER SECTION 208.3 OF FLORIDA
 ACCESSIBILITY CODE, ACCESSIBLE PARKING SPACES ARE TO BE
 LOCATED ON THE SHORTEST POSSIBLE ROUTE OF TRAVEL FROM
 ADJACENT PARKING TO ACCESSIBLE ENTRANCES. THE DESIGN OF
 ACCESSIBLE PARKING SPACES SHALL COMPLY WITH SECTION 502
 OF FLORIDA ACCESSIBILITY CODE
  
 4. ELECTRIC VEHICLE CHARGING STATION. INFORMATIONAL
 COMMENT. IF ELECTRIC VEHICLE (EV) CHARGING STATIONS ARE
 PROVIDED AT LEAST 1 IN 25 MUST COMPLY WITH ACCESSIBLE
 PARKING SPACE REQUIREMENTS.
  
 5. BUILDING SIZE. INFORMATIONAL COMMENT. WHEN SUBMITTED
 FOR BUILDING PERMIT, THE PLANS SHALL SHOW THAT THE TYPE
 OF CONSTRUCTION FOR THE BUILDINGS WILL BE IN ACCORDANCE
 WITH THE HEIGHT, AREA AND OCCUPANCY LIMITATIONS IN
 CHAPTER 5 OF THE FLORIDA BUILDING CODE.
  
 6. ENCLOSED PARKING GARAGES. INFORMATIONAL COMMENT. IF
 THE PARKING GARAGE DOES NOT HAVE WALL OPENINGS, OR
 SUFFICIENT WALL OPENINGS TO MEET THE DEFINITION OF AN
 OPEN PARKING GARAGE, IT WILL BE CONSIDERED AN ENCLOSED
 PARKING GARAGE AND MUST HAVE EXHAUST SYSTEMS. THE
 EXHAUST SYSTEMS SHALL BE DESIGNED TO MINIMIZE NOISE
 LEVELS USING INLINE FAN SILENCERS OR OTHER APPROVED
 METHODS.
  
 7. GREASE INTERCEPTOR. INFORMATIONAL COMMENT. IF ANY OF
 THE COMMERCIAL SPACES WILL BE OCCUPIED BY RESTAURANTS,
 GREASE INTERCEPTOR(S) WILL BE REQUIRED. FOR INFORMATION
 ON THE REQUIRED TYPE, SIZE AND LOCATION, PLEASE CONTACT
 RYAN BROWN, CHIEF PLUMBING INSPECTOR, DEVELOPMENT
 SERVICES DEPARTMENT, AT (561) 805-6692, OR BY EMAIL:
 [email protected]
  
 8. SEPARATE PERMITS REQUIRED. INFORMATIONAL COMMENT.
 ALL APPLICABLE PERMITS AND SUB-PERMITS MUST BE OBTAINED
 BEFORE COMMENCING THE WORK. SEPARATE PERMITS, PLANS AND
 FEES, ARE REQUIRED FOR SIGNS, SWIMMING POOLS AND SPAS,
 GAS SYSTEMS, GENERATORS, FIRE ALARM SYSTEMS, FIRE
 SPRINKLER AND OTHER FIRE SUPPRESSION SYSTEMS, GREASE
 INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE, SITE
 IRRIGATION, ETC.
  
 9. CONTRACTOR VEHICLE PARKING. INFORMATIONAL COMMENT.
 PROPERTY OWNER AND CONTRACTOR SHALL MAKE ARRANGEMENTS
 FOR PARKING OF CONTRACTOR VEHICLES TO MINIMIZE THE
 IMPACT ON ALL NEIGHBORING PROPERTIES.
  
 10. PROTECTION OF NEIGHBORING PROPERTY. INFORMATIONAL
 COMMENT. PROPERTY OWNER AND CONTRACTOR SHALL PROTECT
 ALL NEIGHBORING PROPERTY, INCLUDING VEHICLES, FROM
 DAMAGE OR DIRT CAUSED BY THE CONSTRUCTION, AND SHALL
 NOTIFY THE OCCUPANTS OF NEIGHBORING PROPERTIES ABOUT
 ALL STAGES OF CONSTRUCTION THAT MAY AFFECT THE USE OF
 THEIR PROPERTY.
  
 11. BUILDING ADDRESS. INFORMATIONAL COMMENT. EACH
 SEPARATE BUILDING, AND UNIT WITH AN INDEPENDENT
 ENTRANCE FROM THE STREET, SHALL HAVE A SEPARATE ADDRESS
 ASSIGNED BASED ON THE LOCATION OF THE BUILDING
 ENTRANCE. FOR STREET ADDRESSING, CONTACT CAROLINE
 PUELL, ADDRESSING COORDINATOR, AT (561) 805 6659, OR BY
 EMAIL: [email protected]
  
 ROBERT BROWN
 BUILDING OFFICIAL
 TEL: 561 805 6652
 EMAIL: [email protected]
  
  Print


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved