| 2022-05-12 12:41:22 | CASE NO. FSPR 22-05 |
| | TRANSIT VILLAGE 2022 |
| | 150 CLEARWATER DRIVE |
| | |
| | - CONTACT CHRIS KIMMERLY @ (561) 822-1426, |
| | [email protected] |
| | - OR ERIC SCHNEIDER @ (561) 822-1446, |
| | [email protected] |
| | |
| | - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN |
| | WRITTEN FORMAT. |
| | |
| | - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF THREE |
| | (3) PAPER COPIES AND AN ELECTRONIC COPY IN .PNG AND |
| | .PDF FORMAT OF ALL PLANS. PLEASE NOTE THAT CHANGES ON |
| | THE RESUBMITTED PLANS OR THE SUBMITTAL OF |
| | INFORMATION/PLANS TO ADDRESS THE COMMENTS MAY RESULT IN |
| | ADDITIONAL COMMENTS. |
| | |
| | - THE PPRC COMMENTS SHALL BE SUFFICIENTLY ADDRESSED AND |
| | SUBMITTED TO THE PLANNING DIVISION BY 5 PM ON FRIDAY, |
| | 05/27/22, TO BE ELIGIBLE TO BE SCHEDULED FOR THE |
| | 7/13/22 DOWNTOWN ACTION COMMITTEE MEETING. |
| | |
| | - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT |
| | RECEIVED A RESPONSE TO THE PPRC COMMENTS WITHIN 60 DAYS |
| | FROM THE DATE OF THE PPRC MEETING (BY AUGUST 12, 2022), |
| | THE PLANNING DIVISION MAY NOTIFY THE APPLICANT THAT THE |
| | CASE IS CONSIDERED WITHDRAWN. ANY FURTHER ACTION SHALL |
| | REQUIRE A NEW DEVELOPMENT APPLICATION. |
| | |
| | - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) |
| | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY ISSUED |
| | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE |
| | APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE |
| | WILL BE 20% OF THE ORIGINAL APPLICATION FEE ($500). |
| | |
| | 1. THIS PROPOSED PROJECT IS SIGNIFICANTLY DIFFERENT |
| | THAN THE CURRENTLY APPROVED SITE PLAN; THEREFORE, IT IS |
| | NOT A ?MODIFICATION TO THE EXISTING APPROVED SITE PLAN? |
| | AS STATED IN THE JUSTIFICATION STATEMENT, BUT RATHER A |
| | NEW SITE PLAN APPROVAL. THE PREVIOUSLY APPROVED SITE |
| | PLAN AND THE VARIANCES THAT WERE GRANTED DO NOT |
| | AUTOMATICALLY APPLY TO THE NEW SITE PLAN. ANY VARIANCES |
| | THAT ARE REQUIRED BASED ON THE NEW BUILDING DESIGN AND |
| | SITE LAYOUT REQUIRE APPROVAL BY THE DOWNTOWN ACTION |
| | COMMITTEE THROUGH THE VARIANCE PROCESS. |
| | |
| | 2. STAFF HAS NOTED THAT THE PROPOSED SITE PLAN, |
| | INCLUDING THE USE MIX, DIFFERS FROM THE AGREEMENT FOR |
| | PURCHASE AND SALE DATED AUGUST 12, 2012. SINCE THE |
| | AGREEMENT FOR PURCHASE AND SALE ESTABLISHES THAT |
| | MODIFICATIONS ARE PERMITTED, SUBJECT TO PALM BEACH |
| | COUNTY APPROVAL, PLEASE PROVIDE THE LATEST AMENDMENT OR |
| | VERSION OF THE AGREEMENT FOR PURCHASE AND SALE THAT |
| | AUTHORIZES THE CHANGES PRESENTED IN THE CURRENT |
| | SUBMITTAL, INCLUDING, BUT NOT LIMITED TO: |
| | |
| | A. THE REDUCTION IN THE REQUIRED 40 PARKING SPACES FOR |
| | SFTRA/COUNTY STAFF AND 250 SFRTA PATRON PARKING SPACES |
| | (TOTAL 290 PARKING SPACES) TO 275 PARKING SPACES FOR |
| | THESE USERS. |
| | B. THE REMOVAL OF LEARNING CENTER/CULTURAL/EDUCATION |
| | USES FROM THE PROJECT. |
| | C. THE JUSTIFICATION STATEMENT SITE DATA TABLE LISTS 42 |
| | WORKFORCE HOUSING UNITS AS BEING REQUIRED, WHILE THE |
| | AGREEMENT FOR PURCHASE AND SALE ONLY REQUIRES 38. THE |
| | PLANS DO NOT PROVIDE A BREAKDOWN TO VERIFY COMPLIANCE |
| | WITH EITHER NUMBER. |
| | D. SECTION 3E OF EXHIBIT D TRAFFIC CIRCULATION PLAN OF |
| | THE AGREEMENT FOR PURCHASE AND SALE LIMITS THE NUMBER |
| | OF PARKING SPACES WITHIN THE PARKING GARAGE TO THE 290 |
| | PUBLIC USE PARKING SPACES AND, ??PROVIDE NOT MORE THAN |
| | THE NUMBER OF PARKING SPACES REQUIRED BY THE CITY OF |
| | WEST PALM BEACH FOR THE MIX OF USES AND |
| | INTENSITIES/DENSITIES?AS ACTUALLY CONSTRUCTED??. AS |
| | WILL BE SHOWN LATER IN THESE COMMENTS, THE PROJECT |
| | EXCEEDS THIS STANDARD. |
| | |
| | 3. THE SITE CURRENTLY CONSISTS OF A PBC PARCEL AND AN |
| | SFTRA PARCEL. |
| | A. THE DECKS, COLUMNS AND A PORTION OF THE RETAIL |
| | BUILDING ON THE SOUTH END OF THE SECOND FLOOR CROSS |
| | THIS PARCEL LINE, WHICH CREATE SETBACK AND BUILDING |
| | SEPARATION ISSUES THAT NEED TO BE ADDRESSED. |
| | B. THE AGREEMENT FOR PURCHASE AND SALE INDICATES THAT |
| | PALM BEACH COUNTY WILL RETAIN OWNERSHIP OF THE |
| | INTERMODAL TRANSIT CENTER TO A POINT 21 FEET IN THE |
| | AIR. THE APPLICATION DOES NOT MENTION HOW THIS PROPOSED |
| | SUBDIVISION WILL OCCUR. |
| | C. THE JUSTIFICATION STATEMENT INDICATES THAT THE |
| | AGREEMENT FOR PURCHASE AND SALE INCLUDES THE SFRTA, YET |
| | THEY ARE NOT SHOWN AS A PARTY TO STAFF?S COPY OF THE |
| | AGREEMENT. WILL THE SFRTA RETAIN ANY OWNERSHIP AND IF |
| | SO, HOW WILL THE PARCEL BE SUBDIVIDED? |
| | |
| | 4. TRANSIT VILLAGE BOUNDARY DIAGRAM SHEET A0-03 |
| | DIFFERENT FROM THE ?ITC PROPERTY MAP? AND ?REQUIRED |
| | MODIFICATIONS FROM ORIGINAL APPROVAL IN OCT. 2011. |
| | CLEARLY SHOW THE ITC BOUNDARY ON THE GROUND LEVEL AND |
| | SECOND LEVEL OF THE VARIOUS PLANS. |
| | |
| | 5. THERE ARE NUMEROUS UTILITY AND OTHER EASEMENTS SHOWN |
| | ON THE SURVEY. ALL OF THESE EASEMENTS MUST BE SHOWN ON |
| | THE SITE AND LANDSCAPE PLANS (GROUND LEVEL AND SECOND |
| | LEVEL) TO SHOW THAT THERE IS NO CONFLICT WITH THE |
| | PROPOSED DEVELOPMENT. |
| | |
| | 6. PLEASE DOCUMENT AND IDENTIFY ALL REQUESTED VARIANCES |
| | AND WAIVERS FOR THE PROPOSED SITE PLANS. |
| | |
| | 7. PLEASE PROVIDE AN UPDATED SURVEY CLEARLY DOCUMENTING |
| | THE CHANGES INCORPORATED AS PART OF THE RECENT BANYAN |
| | BOULEVARD STREETSCAPE PROJECT. ALL PLAN SHEETS MUST |
| | REFLECT THE ACCURATE BANYAN STREET CONFIGURATION. THIS |
| | IS CURRENTLY NOT REFLECTED ON ANY OF THE SUBMITTED PLAN |
| | SHEETS. |
| | A. PROPOSED RESIDENTIAL ON-STREET DROP OFF ON BANYAN |
| | FRONTAGE NOT PERMITTED WITHIN TOD-25 DISTRICT. |
| | |
| | 8. SETBACKS ARE MEASURED FROM THE BACK OF CURB, NOT |
| | FROM THE PROPERTY LINE. |
| | A. SETBACK ON BANYAN (GROUND ? 5) IS 16? MIN. AND 50? |
| | MAX. (AVENUE-CLASSIFICATION) CONDITIONAL SETBACK FOR |
| | PARKING ABOVE 5TH STORY IS 31? MIN. |
| | B. SETBACK ON CLEARWATER (GROUND ? 5) IS 12? MIN. AND |
| | 60? MAX. (SECONDARY-CLASSIFICATION) CONDITIONAL SETBACK |
| | FOR PARKING ABOVE 5TH STORY IS 27? MIN. |
| | C. ABUTTING CSX IS 15? MIN. |
| | D. REAR 5? MIN. |
| | E. SIDE INTERIOR 0? OR NFPA |
| | F. SETBACKS INTERNAL TO THE PROPERTY BETWEEN COUNTY |
| | ITC, SFRTA, AND APPLICANT?S PROPERTIES WARRANT FURTHER |
| | DISCUSSION. AS PREVIOUSLY STATED, THE PROJECT SITE IS |
| | SPLIT BETWEEN 2 SEPARATE PARCELS, AND POTENTIAL |
| | VERTICAL SUBDIVISION. |
| | 9. PARKING: THE PARKING TABLE NEEDS TO BE CORRECTED TO |
| | BETTER CONVEY THE PARKING COUNTS. PLEASE NOTE, WHILE |
| | NOT MANDATORY, STAFF HAS INCLUDED THE ADDITIONAL |
| | ALLOWED 25% TOD PARKING SPACE REDUCTION. |
| | A. OFFICE: MIN. 2.5/1000SF = 457 SPACES (MAX. 4/1000SF |
| | = 731 SPACES) AFTER 25% TOD REDUCTION, 343 REQUIRED; |
| | PROVIDING 365 SPACES |
| | B. HOTEL: MIN. 1/4ROOMS = 27 SPACES, 1/800 SF = 11 |
| | SPACES (MAX. 1/ROOM = 108 SPACES, 1/400 SF = 23 |
| | SPACES); AFTER 25% TOD REDUCTION, 29 REQUIRED; |
| | PROVIDING 38 SPACES |
| | C. COMMERCIAL: MIN. 2/1000 SF = 110 SPACES (MAX. 4/1000 |
| | SF = 219 SPACES) AFTER 25% TOD REDUCTION, 83 REQUIRED; |
| | PROVIDING 110 SPACES |
| | D. RESIDENTIAL: MIN. 1/UNIT = 821 SPACE, 1/20 GUEST = |
| | 41 GUEST (MAX. 2/UNIT = 1,642 SPACES, 41 GUEST) AFTER |
| | 25% TOD REDUCTION, 661 REQUIRED; PROVIDING 896 SPACES |
| | TOTAL, NEED A CLEARER BREAKDOWN. |
| | E. MICRO-UNITS: MIN. 0/UNIT (MAX. 0.5/UNIT = 83 SPACES, |
| | 1/20 GUEST = 8 SPACES); PROVIDING? NEED CLEARER |
| | BREAKDOWN. |
| | F. LIVE/WORK UNITS: MIN. 2/1000 SF = 534 SPACES (MAX. |
| | 4/1000SF = 1068 SPACES); AFTER 25% TOD REDUCTION, 400 |
| | REQUIRED; PROVIDING? NEED CLEARER BREAKDOWN. ALSO THERE |
| | ARE A TOTAL OF 12 LIVE/WORK UNITS FOR 267,000 SF, |
| | ASSUMING ~22,250 SF EACH? PLEASE EXPLAIN THESE UNITS. |
| | G. SFRTA AND ITC PARKING: MIN. 290 SPACES (250 FOR |
| | SFRTA PATRONS AND 40 FOR SFRTA/COUNTY); PROVIDING 275? |
| | WHY THE SHORTAGE OF 15 SPACES PER THE PSA? |
| | H. TOTAL MIN REQUIRED: 1,467 SPACES (WITHOUT ANY FOR |
| | MICRO-UNITS AND NOT INCLUDING 534 FOR LIVE/WORK) 2001 |
| | WITH LIVE/WORK INCLUDED; 2,291 WITH SFRTA/ITC PARKING. |
| | NOT COUNTING 25% REDUCTION. PROVIDING 2,003 SPACES WITH |
| | 319 UNALLOCATED. EXPLAIN THE UNALLOCATED. |
| | I. BIKE PARKING: MIN. 1/15 COMMERCIAL/HOTEL/OFFICE = 40 |
| | SPACES REQUIRED, 1/15 RESIDENTIAL = 57 SPACES REQUIRED, |
| | ALSO NEED TO PROVIDE A SHOWER/CHANGING FACILITY WITHIN |
| | 200 FT. OF BUILDING ENTRANCE. PROVIDING 116 COMMERCIAL, |
| | 100 RESIDENTIAL. |
| | I. PROVIDE SECURE RESIDENT BICYCLE ROOMS. PROVIDE |
| | NON-RESIDENTIAL COVERED BICYCLE PARKING AREAS |
| | DISTRIBUTED THROUGHOUT THE SITE. PROVIDE THE DIMENSIONS |
| | FOR THE BICYCLE PARKING AREAS ON THE PLANS. |
| | II. WHERE ARE THE SHOWER/CHANGING FACILITIES LOCATED? |
| | J. IN THOSE CASES WHERE THE SIDE OF ANY PARKING STALL |
| | IS ADJACENT TO A WALL, FENCE, BUILDING, OR OTHER |
| | PHYSICAL OBSTRUCTION, THE STALL WIDTHS SHALL BE |
| | INCREASED BY A MINIMUM OF ONE FOOT. WHERE THERE IS AN |
| | OBSTRUCTION ON BOTH SIDES OF THE STALL, THE STALL |
| | WIDTHS SHALL BE INCREASED BY A MINIMUM OF TWO FEET. |
| | III. PARKING GARAGE HAS INSTANCES WHERE PARKING SPACES |
| | APPEAR TO BE NEXT TO WALLS OR STRUCTURE. |
| | IV. ADA PARKING SPACES ARE LOCATED IN INEFFICIENT AND |
| | NOT OPTIMAL AREAS. ALL SPACES SHALL HAVE ACCESS TO A |
| | CURB RAMP OR CURB CUT, WHEN NECESSARY, TO ALLOW |
| | ENTRANCE TO THE BUILDING SERVED. SPACES SHALL BE |
| | LOCATED SO THAT USERS ARE NOT COMPELLED TO WALK OR |
| | OTHERWISE MOVE BEHIND PARKED VEHICLES, EXCLUDING OTHER |
| | VEHICLES PARKED IN ADJACENT PARKING SPACES FOR THE |
| | DISABLED. |
| | V. PLEASE PROVIDE PARKING PAINTED STRIPING DETAILS THAT |
| | MEET THE CITY STANDARDS OF SEC. 94-485. |
| | VI. PLEASE PROVIDE ALL PARKING DIMENSIONS FOR DRIVE |
| | AISLE, PARKING RAMP SLOPE, PARKING STALLS, ETC. |
| | K. PARKING STRUCTURE RAMP SLOPES: INTERNAL RAMPS APPEAR |
| | 15.8% AND 12.4%. PER SEC. 94-111 (Q.)(2.) IF THE RAMP |
| | IS GREATER THAN 14 PERCENT, A BREAK-OVER TRANSITION |
| | SHALL BE REQUIRED. |
| | L. INTERNAL PARKING STRUCTURE POSES CONCERNS WITH |
| | INGRESS/EGRESS OF RESIDENTS, EMPLOYEES, VISITORS, AND |
| | THE OPERATIONS OF LOADING AND BICYCLE USERS. LOADING |
| | SPACES AND BAYS ARE INEFFICIENT AND CAUSE CONFLICT |
| | ZONES/SAFETY CONCERNS. POTENTIAL SPILLBACK AND QUEUING |
| | ISSUES ONTO CLEARWATER. |
| | M. THE PARKING GARAGE SHOULD BE PREWIRED FOR EV |
| | CHARGERS BOTH FOR RESIDENTS AND CUSTOMERS. THE |
| | ELECTRICAL ROOMS NEED TO BE PROVIDED WITH SUFFICIENT |
| | SPACE TO ACCOMMODATE THE REQUIRED ELECTRICAL PANELS AND |
| | AREAS NEED TO BE DESIGNATED FOR THE TRANSFORMERS. |
| | |
| | 10. CURB-CUTS AND PASSENGER LOAD/DROP-OFF: PER SEC. |
| | 94-111 TABLE IV-11 ? TOD DOES NOT PERMIT ON-STREET |
| | AND/OR PASSENGER DROP-OFF OR LOADING ON AVENUE |
| | (BANYAN). |
| | |
| | 11. PLEASE PROVIDE AN FAR AND GBA DIAGRAM SHOWING THE |
| | BREAKDOWN OF THE PROJECT?S COUNTED/UNCOUNTED ROOMS AND |
| | SPACES. |
| | A. GROSS BUILDING AREA MEANS THE TOTAL FLOOR AREA OF A |
| | BUILDING, INCLUDING AIR-CONDITIONED OR FULLY ENCLOSED |
| | STORAGE SPACES, ENCLOSED AREAS ON THE ROOFTOP, SUCH AS |
| | BATHROOMS AND LOBBIES, STAIRS AND ELEVATOR AREAS, AND |
| | EXTERNAL UNENCLOSED CIRCULATION AREAS. THE GROSS |
| | BUILDING AREA DOES NOT INCLUDE PARKING AREAS; |
| | UNENCLOSED COLONNADES, PORCHES AND BALCONIES; |
| | MECHANICAL AND ELECTRICAL SPACES; AND TRASH ROOMS. |
| | STORAGE SPACES WITHOUT WINDOWS AND ENCLOSED BY SURFACES |
| | THAT ALLOW FOR NATURAL VENTILATION OR OUTSIDE AIR |
| | CIRCULATION SHALL NOT BE INCLUDED. |
| | VII. GROSS BUILDING AREA REQUIREMENTS: |
| | 1. ANY PORTION OF THE PARKING AREA WHICH EXCEEDS THE |
| | MAXIMUM PARKING RATIO SHALL BE INCLUDED IN THE |
| | CALCULATIONS OF GROSS BUILDING AREA. THIS SHALL INCLUDE |
| | STALLS AND ALL ASSOCIATED CIRCULATION AREAS. |
| | 2. PARKING LOCATED BELOW GRADE SHALL NOT BE COUNTED AS |
| | PART OF THE GROSS BUILDING AREA. |
| | 3. THE GROSS BUILDING AREA SHALL BE MEASURED FROM THE |
| | OUTSIDE FACE OF EXTERIOR WALLS. |
| | |
| | 12. PLEASE PROVIDE ACTIVE USE DIAGRAM AND CALCULATIONS |
| | FOR SITE FRONTAGES. |
| | |
| | 13. IT APPEARS THAT THE ELEVATION DRAWINGS DO NOT MATCH |
| | THE GROUND LEVEL SITE PLAN. THE ELEVATION DRAWINGS MUST |
| | INCLUDE HORIZONTAL DIMENSIONS FOR THE VARIOUS FEATURES |
| | SO THAT STAFF CAN VERIFY THAT THE ELEVATIONS MATCH THE |
| | SITE PLAN BUT ALSO THAT THE SITE FRONTAGES COMPLY WITH |
| | THE VARIOUS ZONING REQUIREMENTS. |
| | |
| | 14. PLEASE SPECIFY THE TYPE OF OPEN SPACES (PRIVATE & |
| | PUBLIC) PROVIDED ON THE DRAWINGS, REFERENCE SEC. 94-109 |
| | AND TABLE IV-7. CLARIFY HOW THE REQUIREMENTS OF EACH |
| | OPEN SPACE TYPE IS MET WITHIN THE LANDSCAPE DRAWINGS. |
| | A. PROPOSED OPEN SPACE AT THE SOUTHERN TRIANGLE OF THE |
| | SITE DOES NOT MEET PUBLIC OR PRIVATE OPEN SPACE |
| | TYPOLOGY DUE TO LACK OF ABUTMENT TO AN ACTIVE USE. |
| | B. THE PUBLIC OPEN SPACE SHOWN ON THE SECOND LEVEL |
| | REQUIRES THE APPROVAL OF A VARIANCE, SIMILAR TO THE ONE |
| | APPROVED AS PART OF THE CURRENTLY APPROVED SITE PLAN. |
| | |
| | 15. STREET TREES: STREET TREES SHALL BE PLANTED AT 30 |
| | FT. INTERVALS ALONG EACH STREET FRONTAGE. CLEARWATER |
| | FRONTAGE SHOULD HAVE APPROX. 46 TREES AND BANYAN |
| | FRONTAGE APPROX. 13. |
| | |
| | 16. PROPOSED RESIDENTIAL DROP-OFF AND LOOP FOR |
| | RESIDENTIAL TOWER ON CLEARWATER IS OUTSIDE OF PROPERTY |
| | LINES AND ENCROACHES INTO CITY ROW. ADDITIONAL SMALLER |
| | DROP-OFF ADJACENT TO LOADING BAY/BACK-OF-HOUSE. WHY ARE |
| | THESE DROP-OFF SPACES NEEDED FOR THE RESIDENTIAL TOWER? |
| | ADJACENT HOTEL/OFFICE ALSO INCLUDES A SMALL DROP-OFF, |
| | PRESENTS STACKING/QUEUING ISSUES AND SPILL OVER INTO |
| | CLEARWATER. STAFF DOES NOT SUPPORT THE RESIDENTIAL |
| | DROP-OFF ROAD ADJACENT TO RESIDENTIAL TOWER/CLEARWATER |
| | PROPOSED RESIDENTIAL DROP-OFF NOT IN COMPLIANCE. |
| | ENCROACHES INTO THE PUBLIC RIGHT-OF-WAY AND PER SEC. |
| | 94-111 (N.)(3.) DESIGNATED PASSENGER LOADING AND |
| | DROP-OFF AREAS SHALL BE SET BACK A MINIMUM OF 16 FEET |
| | FROM THE BACK OF CURB, SHALL BE SEPARATED FROM THE |
| | SIDEWALK BY A 5-FOOT-WIDE LANDSCAPE BUFFER AND SHALL BE |
| | SUBJECT TO APPROVAL BY THE CITY TRAFFIC ENGINEER. PORTE |
| | COCHERES ARE SUBJECT TO MINIMUM STANDARDS DEPENDING ON |
| | SUBDISTRICT LOCATION AND ADJACENCY TO A STREET |
| | DESIGNATION AND ARE SEPARATED INTO TWO TYPES WHICH ARE |
| | ILLUSTRATED IN FIGURE IV-22. ONLY A TYPE A PORTE |
| | COCHERE IS ALLOWED IN THE TOD-25 SUBDISTRICT. |
| | A. INSTEAD, THE BUILDING FRONT SHOULD BE MOVED CLOSER |
| | TO CLEARWATER, AND RECONFIGURE LOADING AND |
| | BACK-OF-HOUSE TO INCLUDE THE DRIVEWAY AND DROP OFF |
| | AREA. |
| | B. SEE ABOVE: PROPOSED LOADING SPACE ON RESIDENTIAL |
| | TOWER DOES NOT FUNCTION FOR VEHICULAR MOVEMENT. |
| | |
| | 17. ITC BUS LOOP IS NOW ENTIRELY COVERED OVERHEAD BY |
| | PLAZA AND BUILDINGS/STRUCTURES. PREVIOUS DESIGN HAD AN |
| | OPEN-AIR CORRIDOR TO PROVIDE LIGHT, LANDSCAPING, AND |
| | VENTILATION/OPEN-AIR ACCESS. HOW WILL THE REMOVAL OF |
| | THESE ELEMENTS BE MITIGATED OR COMPENSATED FOR, |
| | ESPECIALLY WHERE ANY MECHANICAL VENTING WILL BE |
| | LOCATED? |
| | |
| | 18. PLEASE PROVIDE SHEETS AND DRAWINGS IDENTIFYING HOW |
| | THE FA?ADE ARTICULATION REQUIREMENTS ARE MET FOR THE |
| | PROJECT. PLEASE REFERENCE SEC. 94-109 AND TABLE IV-4: |
| | FA?ADE ARCHITECTURAL REQUIREMENTS. |
| | A. ILLUSTRATE TRANSPARENCY CALCULATIONS, FENESTRATION |
| | CALCULATIONS, PLANAR BREAK CALCULATIONS, PROJECTIONS, |
| | ETC. FOR ALL BUILDING FACADES. |
| | |
| | 19. PLEASE PROVIDE DETAILS AND MATERIALS OF THE GARAGE |
| | STRUCTURE, HOW IS IT BEING SCREENED, MATERIALS, PLANTS, |
| | ETC. |
| | |
| | 20. REGARDING THE ARCHITECTURAL DESIGN OF THE TOWERS, |
| | HAS VARIED FACADES AND ELEMENTS BEEN EXPLORED OR IS |
| | THERE A REASON FOR UNVARIED/SIMILARLY DESIGNED TOWERS? |
| | |
| | 21. REGARDING THE TOWERS AND OVERALL PROJECT HEIGHT, |
| | STAFF REQUESTS THAT THE BANYAN RESIDENTIAL TOWER IS THE |
| | TALLEST RATHER THAN THE CLEARWATER HOTEL/OFFICE TOWER. |
| | THIS IS BECAUSE BANYAN IS THE WIDEST ROADWAY AND IS |
| | MORE APPROPRIATELY FRAMED/CAN ACCOMMODATE THE TALLER |
| | MASS. ADDITIONALLY, STAFF RECOMMENDS THAT THE BANYAN |
| | RESIDENTIAL TOWER STEPS DOWN IN SOME CAPACITY TOWARD |
| | TAMARIND AVE. AS WAS APPROVED WITHIN THE ORIGINAL SITE |
| | PLAN. THIS GIVES RESPECT TO THE SCALE OF THE SEABOARD |
| | TRAIN STATION AND PUBLIC REALM ALONG TAMARIND. |
| | |
| | 22. BE COGNIZANT THAT THE EDGE 2 BUILDING LOCATED AT |
| | 300 CLEARWATER IS APPROVED AND UNDERGOING BUILDING |
| | PERMITTING PROCESS, THIS PROJECT?S INGRESS/EGRESS FROM |
| | DRIVES MAY PRESENT CONFLICT POINTS. THE GROUND LEVEL |
| | PLANS NEED TO SHOW THE EDGE 2 CURB CUTS IN ORDER FOR |
| | STAFF TO EVALUATE THE IMPACT OF THE ACCESS POINTS TO |
| | CLEARWATER. ADDITIONALLY, THE PEDESTRIAN CONNECTION |
| | FROM THE ?OASIS? PARK ELEMENT ACROSS CLEARWATER TO THE |
| | STAIRWELL/ELEVATOR FOR THE UPPER PLAZA WILL NEED |
| | RECONSIDERATION WITH THE INCOMING DEVELOPMENT. |
| | |
| | 23. PLEASE CLARIFY GROUND FLOOR PEDESTRIAN CIRCULATION |
| | WITH ITC, ACCESSING UPPER PLAZA SPACES, AND INTERNAL |
| | CIRCULATION BETWEEN RETAIL AND RESIDENTIAL TOWERS. IS |
| | THE ITC BUS LOOP SEPARATED/CLOSED OFF IN THE EVENINGS |
| | WHEN BUS OPERATIONS HALT, HOW IS WAYFINDING ADDRESSED |
| | TO ACCESS THE UPPER PLAZA SPACES? |
| | A. THE ITC ADA PATH DRAWING SUBMITTED WITH THE |
| | APPLICATION SHOWS THE ADA ROUTE UTILIZING A CROSSWALK |
| | THAT IS DESIGNATED FOR REMOVAL. |
| | B. THE ITC FENCE EXHIBIT SHOWS THE FENCE AROUND THE |
| | OPEN SPACE AT THE SOUTH END OF THE SITE AS A ?PRIVATE |
| | PARK FENCE?. THIS DOES NOT MATCH THIS AS BEING DEPICTED |
| | AS PUBLIC OPEN SPACE ON OTHER PLANS. |
| | |
| | 24. STAFF WILL BE RECOMMENDING PEDESTRIAN IMPROVEMENTS |
| | AND INCREASED ACCESSIBILITY TO TAMARIND AND THE |
| | DOWNTOWN AREA. AS A TOD PROJECT, YOU MUST DEMONSTRATE |
| | HOW THE RELATION AND CONNECTIVITY IS IMPROVED TO THESE |
| | CORRIDORS INTO THE DOWNTOWN. RECOMMEND POTENTIAL: WORK |
| | WITH SFRTA TO IMPLEMENT AT-GRADE CONNECTION(S) ACROSS |
| | RAILS TO TAMARIND. IMPROVE THE PEDESTRIAN BRIDGE |
| | CONNECTING SEABOARD TRAIN STATION AND TRANSIT VILLAGE |
| | PROJECT. EXPLORE CONCEPT OF ADDITIONAL PEDESTRIAN |
| | BRIDGES OR CONNECTIONS. |
| | |
| | 25. PLEASE PROVIDE INFORMATION ON WHAT THE ?MOTOR |
| | LOBBY? IS. |
| | |
| | 26. THE SOUTH RESIDENTIAL BUILDING IS NOT PERMITTED TO |
| | ENCROACH THE 20-FOOT FIRE DEPARTMENT ACCESS EASEMENT. |
| | NOTE: EVEN WITHOUT THE BUILDING ENCROACHMENT, THIS DOES |
| | NOT FUNCTION. |
| | |
| | 27. PROVIDE TURNING DIAGRAMS FOR THE LOADING AREAS |
| | UNDER THE NORTH BUILDING, ENTRY POINTS TO THE SITE AND |
| | THE OTHER LOADING AREAS. |
| | |
| | 28. WHERE ARE THE GENERATORS, TRANSFORMERS, AND OTHER |
| | MECHANICAL EQUIPMENT AND HOW ARE THEY SCREENED IN |
| | ACCORDANCE WITH CITY CODE REQUIREMENTS? |
| | |
| | 29. PLEASE CONSIDER USING SUSTAINABLE INFRASTRUCTURE |
| | SUCH AS ROOFTOP SOLAR OR RAINWATER CAPTURE/REUSE |
| | CISTERNS. |
| | |
| | 30. SHEET A6-01 SHOWS PUBLIC OPEN SPACES EXTENDING INTO |
| | THE BUS LANE. |
| | |
| | 31. FOR THE EVENTUAL DOWNTOWN ACTION COMMITTEE (DAC) |
| | MEETING, PLEASE PROVIDE FULLY DETAILED RENDERINGS AND |
| | PERSPECTIVE DRAWINGS OF THE FINAL PROJECT. |
| | 32. PROVIDE A PRELIMINARY CONSTRUCTION PLAN TO SHOW HOW |
| | THE SITE WILL BE DEVELOPED WHILE MAINTAINING ITC |
| | OPERATIONS, TO INCLUDE PARKING. ADDITIONALLY, PROVIDE |
| | THE PRELIMINARY PLAN FOR EMPLOYEE AND CONTRACTOR |
| | PARKING DURING CONSTRUCTION. |
| | |
| | 33. THERE ARE COLUMN LOCATIONS THAT WHEN COMBINED WITH |
| | THE LOCATION OF THE PROPOSED ITC FENCE CREATE CHOKE |
| | POINTS FOR THE BUS PATRONS AS THEY CHANGE BETWEEN |
| | ROUTES. WHILE THEY ALL APPEAR TO COMPLY WITH ADA |
| | MINIMUMS, THEY DO NOT PROVIDE COMFORTABLE PEDESTRIAN |
| | WIDTHS FOR TWO USERS TO PASS SIDE-BY-SIDE. PLEASE |
| | REVIEW. |
| | |
| | 34. THE SITE, LANDSCAPE AND CIVIL PLANS ALL NEED TO |
| | SHOW CONSISTENT, CODE COMPLIANT CONDITIONS. |
| | |
| | 35. PROVIDE VERIFICATION THAT THE PROJECT MEETS THE |
| | STREETSCAPE REQUIREMENTS OF SECTION 94-113. THIS |
| | INCLUDES LIGHTING, SIDEWALK WIDTH, LANDSCAPE, BICYCLE |
| | PARKING, STREET FURNITURE, ETC. |
| | |
| | 36. PROVIDE COMPLIANCE WITH SEC. 94-106 ? GENERAL USES |
| | WITH SPECIAL REQUIREMENTS (8.A) MICRO-UNITS (A.-F.) |
| | A. MICRO-UNIT MEANS A SMALL RESIDENTIAL UNIT WITH A |
| | TOTAL SQUARE FOOTAGE BETWEEN 300 SQUARE FEET AND 549 |
| | SQUARE FEET, WITH A FULLY FUNCTIONING KITCHEN AND |
| | BATHROOM. |
| | B. SEC. 94-109 ?DWELLING UNIT REQUIREMENTS |
| | VIII. DWELLING UNITS SHALL NOT BE LESS THAN 550 SQUARE |
| | FEET. IN MULTIPLE DWELLING UNIT BUILDINGS, THE |
| | CUMULATIVE AVERAGE OF ALL DWELLING UNITS SHALL NOT BE |
| | LESS THAN 800 SQUARE FEET. |
| | IX. SMALLER DWELLING UNITS MAY BE ALLOWED AS |
| | MICRO-UNITS. THE CUMULATIVE AVERAGE SIZE MINIMUM SHALL |
| | NOT BE APPLICABLE TO MULTIPLE DWELLING UNIT BUILDINGS |
| | WHERE MICRO-UNITS COMPOSE A MINIMUM OF 80 PERCENT OF |
| | THE TOTAL NUMBER OF UNITS. IN ALL OTHER CASES, THE |
| | CUMULATIVE AVERAGE SIZE OF ALL DWELLING UNITS SHALL NOT |
| | INCLUDE THE MICRO-UNITS IN SUCH CALCULATION. SEE |
| | MICRO-UNITS. |
| | |
| |