2022-05-10 17:13:46FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER
 561-822-1462
 PROJECT: TRANSIT VILLAGE Z22040014
 MAY 10, 2022
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
  
 1. SECTION 94-448 (D)(3) REQUIRES NATIVE TREES AND
 PALMS IN GOOD CONDITION TO BE PRESERVED ON SITE OR
 RELOCATED. ANSI A 300 (PART 5) STANDARDS SPECIFY
 EXAMPLES OF SUITABILITY RATINGS OF GOOD, MODERATE, OR
 POOR FOR RELOCATION. PROVIDE AN ARBORISTS REPORT RATING
 THE CONDITION AND RELOCATION POTENTIAL FOR THE NATIVE
 TREES AND PALMS. THE TREE DISPOSITION MUST INDICATE
 WHETHER THE TREE WILL BE PRESERVED, RELOCATED OR
 REMOVED.
 2. PROVIDE THE INDIVIDUAL AND TOTAL CANOPY MITIGATION
 DUE FOR ANY PROPOSED REMOVALS. TREES PROPOSED TO BE
 REMOVED WITH A CANOPY DIAMETER OF 20 FEET OR MORE
 SHOULD HAVE THE MITIGATION SQUARE FOOTAGE CALCULATED
 BASED ON THE ACTUAL DIAMETER. TREES LESS THAN 20 FEET
 CANOPY DIAMETER AND PALMS SHOULD SHOW THE CATEGORY
 MITIGATION DUE.
  
 3. PROVIDE A DIAGRAM OF THE REQUIRED AND PROVIDED
 PUBLIC AND PRIVATE OPEN SPACE AREAS FOR THE ZONING
 DISTRICT. IDENTIFY THE TYPE OF OPEN SPACE AS ALLOWED BY
 TABLE IV-7 AND DEFINITIONS IN SECTION 94-109. SHOW HOW
 THE STANDARDS FOR THE TYPES OF OPEN SPACE ARE MET FOR
 VEGETATED AREAS AND TREE CANOPY SQUARE FOOTAGE BASED ON
 TABLE IV-8 ON THE LANDSCAPE PLAN. LANDSCAPE PLANS MUST
 MATCH THE ARCHITECTURAL PLANS AND CLEARLY IDENTIFY THE
 OPEN SPACE TYPE THEN DEMONSTRATE HOW THE REQUIREMENTS
 OF THAT TYPE ARE MET.
 TERRACE IS IDENTIFIED AS THE PRIVATE OPEN SPACE TYPE ON
 SHEET L002, BUT OTHER LABELS LIKE PLAZA FOR LEVEL 2 AND
 ROOFTOP PLAZA FOR LEVEL 4 APPEAR ON THE OTHER SHEETS.
 LEVEL 9 IS LABELED AS TERRACE BUT HAS THE
 CHARACTERISTICS OF ROOFTOP GARDEN.
 IN SUMMARY, THE REQUIRED OPEN SPACE NEEDS TO BE
 QUANTIFIED, IDENTIFIED AS TO THE TYPE, AND ALL
 REQUIREMENTS NEED TO BE SHOWN FOR THAT OPEN SPACE TYPE.
  
  
 4. ALL OPEN SPACE TYPES REQUIRING TREE CANOPY MUST SHOW
 THE TREE CANOPY SQUARE FOOTAGE FOR TREE TYPES BASED ON
 TABLE IV-8 AND PROVIDE THE TOTAL.
  
  
 5. IDENTIFY RELOCATED TREES OR PALMS ON THE PLANT LIST
 AND COUNT THEM TOWARD THE REQUIRED TREES IF THEY ARE TO
 BE USED ON SITE.
  
 6. PROVIDE INFORMATION ON THE REDUCTION OF THE GREEN
 SCREEN AREA FROM WHAT WAS APPROVED BY COMPARISON OF THE
 SQUARE FOOTAGE FROM THE ORIGINAL APPROVAL AND WHAT IS
 PROPOSED. PROVIDE DETAILS ON THE STRUCTURE AND THE
 PLANT MATERIAL.
  
 7. THE AREA WITHIN THE BUS LOOP IS PROPOSED TO HAVE
 MOSAIC TILE RATHER THAN THE PLANTINGS ORIGINALLY
 APPROVED. DESCRIBE HOW THE ENVIRONMENT WILL BE IMPROVED
 WITHIN THE BUS LOOP.
  
 8. LANDSCAPE SHEETS ARE IN TOO SMALL A SCALE TO CLEARLY
 IDENTIFY ALL PLANT MATERIAL. NEED TO BE SHOWN ON
 SEPARATE SHEETS AT A LARGER SCALE.
  
 9. ARTIFICIAL TURF AREAS PROPOSED MUST MEET THE
 REQUIREMENTS OF SECTION 94-451, INCLUDING ALL AREAS
 THAT ARE ALLOWED BY CODE MUST NOT BE VISIBLE FROM A
 ROAD OR STREET.
  
  
 10. PROVIDE CALCULATIONS FOR REQUIRED STREET TREES AT
 MAXIMUM SPACING EVERY 30 FEET OR PORTION THEREOF FOR
 EACH STREETSCAPE LENGTH, AND SHOW THE NUMBER PROVIDED
 PER SECTION 94-113 AND 94-116. THE BANYAN STREETSCAPE
 IMPROVEMENTS NEED TO BE INCLUDED ON THE PLANS TO SHOW
 THE INTEGRATION OF THIS PROJECT WITH THE STREETSCAPE.
  
 11. EXPLAIN IF THE EXISTING FPL TRANSMISSION LINES WILL
 STAY IN PLACE OR BE RELOCATED.
  
 12. SHOW ALL EXISTING AND PROPOSED WATER AND SEWER AND
 DRAINAGE LINES ON THE LANDSCAPE PLAN. SHOW LOCATIONS OF
 BACKFLOWS AND ADJUST LOCATIONS OF UTILITY LINES TO
 RESOLVE CONFLICTS WITH EXISTING AND PROPOSED TREES AND
 LANDSCAPING.
  
 13. PLANT LIST NEEDS TO BE MODIFIED TO INCLUDE ALL
 PLANT MATERIAL FOR THE PROJECT,
 AND SEPARATE PLANT LIST FOR EACH OPEN SPACE AREA
 PROVIDED FOR REFERENCE TO SHOW COMPLIANCE WITH THE OPEN
 SPACE TYPE REQUIREMENTS.
  
 14. SHOW COMPLIANCE WITH SECTION 94-445 L. PLANT
 SPECIES. A MINIMUM OF 60 PERCENT OF PLANT MATERIAL
 ADDED SHALL BE FLORIDA NATIVE OR DROUGHT TOLERANT
 SPECIES SELECTED FROM THE CITY LIST OR THE LIST OF
 SPECIES IN THE MOST RECENT EDITION OF SOUTH FLORIDA
 WATER MANAGEMENT DISTRICT WATERWISE SOUTH FLORIDA
 LANDSCAPES. PROVIDE THE ACTUAL PERCENTAGE BASED ON THE
 PLANT LIST.
  
  
 15. PROVIDE SCREENING HEDGES FOR ALL GROUND MOUNTED
 VALVES AND EQUIPMENT AND ADD A NOTE THAT ALL EQUIPMENT
 WILL BE SCREENED.
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE
 RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE
 STREET TREES AND RIGHT OF WAY LANDSCAPING AND
 IRRIGATION APPROVED WITH THIS PETITION.
 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE
 RESPONSIBLE FOR THE MAINTENANCE OF THE STREET TREES AND
 RIGHT OF WAY LANDSCAPING AND IRRIGATION. THIS WILL BE
 THROUGH A SEPARATE MAINTENANCE AGREEMENT WITH THE CITY.
  