| 2022-03-04 08:11:19 | Z22020023 ? 695 S OLIVE HOTEL ? 2-23-22 REVIEW |
| | |
| | MARK HURLEY, FIELD CUSTOMER SERVICE SUPERVISOR WITH |
| | CITY OF WPB PUBLIC UTILITIES, REGARDING PLACEMENT OF |
| | BACKFLOW DEVICES AND WATER METERS. CONTACT HIM AT |
| | 561-822-2262 OR [email protected] |
| | |
| | -WHY IS APPLICANT SEEKING CHANGE OF USE FROM |
| | RESIDENTIAL MICRO UNITS TO HOTEL? |
| | |
| | -CALLOUT ON SHEET A1-01 DOUBLE DETECTION CHECK VALVE |
| | AND WATER METER UNDER GROUND - SEE CIVIL DWGS NEEDS TO |
| | BE UPDATED AS DDCV CANNOT BE UNDER GROUND. |
| | |
| | -PLANTING PLAN LP 1.01 DOES NOT MATCH FIELD CONDITIONS |
| | AS OF 25FEB2022 WITH REGARD TO BUSHES AND LANDSCAPING |
| | AROUND WATER METER VAULT. IS PLAN CORRECT AND CHANGE |
| | INTENDED? |
| | |
| | -UTILITY PLAN DOES NOT SHOW GREASE INTERCEPTOR FOR ONE |
| | OF THE PROPOSED RESTAURANT/RETAIL SPACES. APPLICANT |
| | NEEDS TO COMPLY WITH ANY GREASE INTERCEPTOR |
| | REQUIREMENTS IF RESTAURANT IS ESTABLISHED THERE. |
| | |
| | -WOULD HOTEL PORTION HAVE ANY FOOD SERVICE REQUIRING |
| | INSTALLATION OF GREASE INTERCEPTOR? |
| | |
| | -VERIFY PEDESTRIAN AND UTILITY EASEMENTS ARE RECORDED |
| | AS SHOWN ON UTILITY PLAN. |
| | |
| | -VERIFY IF THE WATER AND SEWER UTILITIES SHOWN ON |
| | UTILITY PLAN HAVE ALREADY BEEN BUILT, AND INDICATE IF |
| | ANY CHANGES ARE PROPOSED TO UTILITIES FROM MICROUNITS |
| | PLAN TO HOTEL PLAN. |
| | |
| | |
| |