| 2022-08-12 16:17:58 | TRAFFIC ANALYSIS COMMENTS |
| | 1) PARTIALLY SATISFIED. PROVIDE A FULL TRAFFIC STUDY |
| | ACCORDING TO COUNTY ARTICLE 12. PLEASE CONTACT THE |
| | TRANSPORTATION GROUP TO SCHEDULE A METHODOLOGY MEETING. |
| | NOT ALL DISCUSSED ITEMS HAVE BEEN PROVIDED IN THE |
| | ANALYSIS. A SECOND METHODOLOGY MEETING IS NEEDED |
| | 2) SATISFIED. PROJECT DISTRIBUTION FIGURE. QUADRILLE |
| | PLAZA DR IS MISSING |
| | 3) SATISFIED. TABLE 1. PROVIDE THE |
| | STARRED/SUPERSCRIPTED REFERENCES |
| | 4) SATISFIED. TABLE 4. DATURA STREET GOES FROM TAMARIND |
| | TO QUADRILLE PLAZA DR |
| | 5) SATISFIED. PROVIDE TABLE(S) AND/OR REFERENCES |
| | HIGHLIGHTING SIGNIFICANTLY IMPACTED STREETS AND |
| | INTERSECTIONS |
| | 6) SATISFIED. PROVIDE COUNTY TPS LETTER, ONCE OBTAINED |
| | 7) SATISFIED. THE ALLEYWAY IS PLANNED TO BE DESIGNATED |
| | ONE-WAY EASTBOUND. SHOWCASE CORRESPONDING PAVEMENT |
| | MARKING AND SIGNAGE |
| | 8) MAJOR IMPACTED CORRIDORS AND INTERSECTIONS NEED TO |
| | BE FURTHER ANALYZED. PLEASE CONTACT ENGINEERING |
| | SERVICES TO COORDINATE THIS ITEM |
| | 9) PLEASE PROVIDE AN INITIAL LIST OF TDM MEASURES |
| | 10) PLEASE INCLUDE THE LATEST SITE PLAN IN THE APPENDIX |
| | |
| | SITE PLANS COMMENTS |
| | 11) PROVIDE A CLEAN TRANSPORTATION SPECIFIC SITE PLAN |
| | FOR THE GROUND FLOOR. SHOWCASING TRANSPORTATION RELATED |
| | FEATURES (E.G. ROADWAY WIDTHS, DRIVING AISLES, PARKING |
| | STALLS, SIDEWALK, CURB, GUTTER, DRIVEWAY, GATES, |
| | CROSSWALKS, SIGNAGE & PAVEMENT MARKINGS ETC.) PROPERLY |
| | LABELED AND DIMENSIONED. SHEET A-1 IS A STARTING POINT. |
| | 12) SATISFIED. ON THE SITE PLAN, PLEASE SHOWCASE BASIC |
| | CURB DETAILS (I.E. DRIVEWAY AND PARKING STALLS) ON THE |
| | OPPOSITE SIDE OF THE ROADS SURROUNDING THE PROPOSED |
| | DEVELOPMENT. PLEASE PROVIDE DOCUMENT NAME AND SHEET |
| | NUMBER SHOWCASING SUCH FEATURES |
| | 13) NOT SATISFIED. PROVIDE AUTOTURN ANALYSIS FOR |
| | GARBAGE TRUCK AND/OR SERVICE VEHICLES DRIVING IN AND |
| | OUT OF THE PROPOSED DEVELOPMENT WITH VEHICLE DYNAMIC |
| | ENVELOPES CLEARLY DEFINED. ANALYSIS SHOULD BE PROVIDED |
| | IN A SEPARATE FILE/DRAWING. PLEASE PROVIDE DOCUMENT |
| | NAME AND SHEET NUMBER IN THE RESPONSE LETTER |
| | 14) PARTIALLY SATISFIED. IDENTIFY AND DESIGNATE AN |
| | EASILY ACCESSIBLE MICRO-MOBILITY STATION AREA (MINIMUM |
| | 8 X 20 FEET) AND PROVIDE BASIC ELECTRIFICATION |
| | READINESS. FOR THE LATTER ITEM, MORE SPECIFICALLY: A |
| | CONDUIT (2 INCH SCHEDULE 40 PVC) TO THE POWER SOURCE |
| | WITH AN ELECTRICAL PULL BOX (240V CIRCUIT). PLEASE |
| | PROVIDE DOCUMENT NAME AND SHEET NUMBER SHOWCASING SUCH |
| | FEATURE. CITY INSTALLED BIKE SHARE STATION DOES NOT |
| | STRICTLY FULFIL THIS REQUIREMENT; FURTHER DISCUSSION IS |
| | NEEDED |
| | 15) NOT SATISFIED. PROVIDE PARKING TABLE SHOWCASING THE |
| | NUMBER OF REQUIRED AND/OR PROVIDED PARKING SPACES, |
| | INCLUSIVE OF ADA AND BICYCLE ONES. ARCHITECTURAL PLANS |
| | SHOW PARKING STALLS AND BIKE RACKS IN THE GROUND FLOOR. |
| | PLEASE PROVIDE DOCUMENT NAME AND SHEET NUMBER |
| | CONTAINING SUCH TABLE IN THE RESPONSE LETTER |
| | 16) SATISFIED. CLEARLY MARK THE REQUIRED LOADING ZONE |
| | LOCATION AND ITS DIMENSION |
| | 17) PARTIALLY SATISFIED. ALLEYWAY MUST BE REPAVED ALONG |
| | SITE FRONTAGE, BUT IDEALLY IN FULL BETWEEN QUADRILLE |
| | PLAZA DR AND ROSEMARY AVE. PROVIDE STATUS OR OUTCOME OF |
| | THE FINAL SCOPE |
| | 18) GATE(S) OPERATIONS SHOULD NOT INTERFERE WITH |
| | VEHICULAR TRAFFIC LANES, SIDEWALKS AND BICYCLE LANES. |
| | ANY GATE AT THE DRIVEWAY SHOULD BE SET BACK AT LEAST 25 |
| | FEET FROM THE BACK OF SIDEWALK AND EDGE OF PAVEMENT. |
| | PLEASE REVISE PLANS ACCORDINGLY. THIS IS A MAJOR ITEM |
| | TO BE ADDRESSED, AS CURRENT GATES CONFIGURATION AND |
| | CORRESPONDING VEHICULAR OPERATIONS WOULD SIGNIFICANTLY |
| | AND NEGATIVELY IMPACT THE TRAFFIC FLOW ALONG THE |
| | ALLEYWAY |
| | 19) SIDEWALKS: A MINIMUM OF 8 FEET UNOBSTRUCTED |
| | WALKABLE AREA NEEDS TO BE PROVIDED. LANDSCAPE OR |
| | PLANTING AREAS DO NOT COUNT TOWARDS SUCH WIDTH |
| | |
| | VALERIO ORICCHIO |
| | CITY TRANSPORTATION ENGINEER |
| | 561-494-1092 |
| | [email protected] |
| | |
| | |
| |