Plan Review Notes
Plan Review Notes For Project Z22020019
Project Number Z22020019
Review Stop Z
Sequence Number 1
Notes
Date Text
2022-03-08 16:44:071. THIS PROJECT IS PRESENTED AS THE DMP HIP OFF-SITE
 REQUIREMENT FOR A PROPOSED PROJECT AT THE SE CORNER OF
 FERN ST AND QUADRILLE BOULEVARD. HOWEVER, THE PARENT
 PROJECT HAS NOT BEEN SUBMITTED YET, AND STAFF CANNOT
 VERIFY THE HIP REQUIREMENT. SOME GENERAL COMMENTS FOR
 CONSIDERATION ARE:
 A. OFF-SITE UNITS SHALL MATCH THE UNIT SIZE AND TYPE OF
 THE PARENT PROJECT. A 100% MICRO UNIT PROJECT WILL NOT
 COMPLY WITH THIS REQUIREMENT UNLESS THE PARENT PROJECT
 IS A 100% MICRO UNIT PROJECT.
 B. REQUIRED SET-ASIDE SQUARE FOOTAGE IS NET SF, NOT
 INCLUDING CORRIDORS.
 2. A SURVEY FOR THE CITY-OWNED PARCEL SHALL BE INCLUDED
 WITH THE APPLICATION. SITE AREA SHALL REFLECT THE
 INFORMATION PROVIDED IN SURVEY (512 CLEMATIS ARE PER
 SURVEY = 18,387SF VS 18,361 IN SHEET A-1)
 3. PROPOSED WEST ELEVATION DOES NOT MEET THE BLANK WALL
 MAXIMUM REQUIREMENTS. A MAXIMUM OF 20% OF AN ELEVATION
 CAN BE A BLANK WALL (ABSENT OF FENESTRATION). PLEASE
 EXPLORE POSSIBLE WINDOWS COMPLIANT WITH FIRE
 REQUIREMENTS FOR THE SETBACK PROPOSED OR INCREASE THE
 SETBACK.
 4. PLEASE INDICATE THE LOCATION OF THE EXISTING WINDOW
 ON ADJACENT BUILDING AND CHANGES NEEDED TO COMPLY WITH
 FIRE CODE, IF REQUIRED.
 5. FIRE DCDA ALONG QUADRILLE PLAZA DRIVE SHALL BE
 RELOCATED TO THE ALLEY.
 6. IRRIGATION METER SHALL BE RELOCATED TO THE ALLEY.
 7. PROPOSED MANHOLES WILL NOT BE PERMITTED ALONG
 CLEMATIS STREET.
 8. PROPOSED DOORS ALONG FA?ADE SHALL NOT ENCROACH MORE
 THAN 18 INCHES INTO THE MINIMUM SETBACK.
 9. PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE
 WITH MICRO-UNIT REGULATIONS IN SEC 94-106 (8.A)
 REGARDING CAR SHARING AND BIKE PARKING. PLEASE INDICATE
 THE LOCATION OF THE MICRO-MOBILITY STATION ALONG
 CLEMATIS STREET.
 10. BASED ON THE CURRENT PROPOSAL TO PROVIDE 89 MICRO
 UNITS, THE PROJECT IS REQUIRED TO PAY $10 PER
 UNIT/MONTH TO SUPPORT THE TROLLEY OPERATION. IF THE
 PROJECT PARTICIPATES IN THE HIP TROLLEY CONTRIBUTION
 WILL NOT BE REQUIRED.
 11. PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE
 WITH THE BIKE PARKING REQUIREMENT ALONG THE STREET
 FRONTAGE (1 SPACE /100 FEET OF FRONTAGE).
 12. STREETSCAPE DESIGN ALONG QUADRILLE PLAZA DRIVE
 SHALL BE AS FOLLOWS:
 A. PLANTING STRIP SHALL BE PROVIDED BETWEEN THE
 EXISTING TREES (4 FEET IN WIDTH).
 B. BASE PLANTING ALONG EAST ELEVATION SHALL BE REDUCED
 TO 2 FEET IN WIDTH TO ACCOMMODATE A 10 FEET WIDE
 SIDEWALK.
 13. PLEASE INDICATE IF THE PROPOSED PARKING AT GROUND
 FLOOR IS FOR RETAIL OR RESIDENTIAL TENANTS.
 14. LOADING IS NOT REQUIRED FOR THIS PROJECT (LESS THAN
 50,000SF LOT) HOWEVER CONSIDERING THE POSSIBLE HIGH
 TURN-AROUND OF MICROUNITS STAFF RECOMMENDS THE PROJECT
 TO ACCOMMODATE SOME LOADING FROM THE ALLEY. THE AREA IS
 ALREADY VERY CONGESTED WITH COMMERCIAL DELIVERIES.
 15. PLEASE CLARIFY IF THE MICROUNITS ARE PROPOSED AS
 FULLY FURNISHED UNITS.
 16. PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE
 WITH REQUIRED SCREENING FOR ROOF TOP MECHANICAL
 EQUIPMENT. A SCREEN SHALL BE PROVIDED AROUND THE
 EQUIPMENT AS CLOSE AS PERMITTED BY THE EQUIPMENT
 CLEARANCE REQUIREMENT.
 17. EXTERIOR CORRIDORS (2ND FLOOR) SHALL BE COUNTED AS
 PART OF THE GROSS BUILDING AREA.
 18. PLEASE IDENTIFY IF ANY HORIZONTAL PROJECTIONS ARE
 ENCROACHING INTO THE ROW. CANOPY OVER QUADRILLE PLAZA
 DRIVE?
 PLEASE RESUBMIT ONE PRINTED COPY OF REVISED DRAWINGS
 AND A RESPONSE SHEET AND ELECTRONIC COPIES OF ALL
 DOCUMENTS.
 FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439.