Plan Review Notes
Plan Review Notes For Project Z21110019
Project Number Z21110019
Review Stop TRAFFIC
Sequence Number 2
Notes
Date Text
2022-01-14 18:29:07TRAFFIC COMMENTS
 1) PARTIALLY SATISFIED. PROVIDE THE 2007 STUDY
 JUSTIFYING THE TRIP GENERATION CALCULATIONS. THE
 PROVIDED STUDY IS INCOMPLETE, SOME FIGURES AND TABLES
 ARE MISSING
 2) PARTIALLY SATISFIED. PROVIDE DOCUMENTATION
 SUBSTANTIATING VESTED TRIPS AND APPROVED DRIVEWAYS.
 PLEASE SCHEDULE A MEETING TO REVIEW LATEST TRAFFIC
 STUDY ASSUMPTIONS AND RESULTS.
 3) SATISFIED. PROVIDE COUNTY TPS LETTER
 4) NOT SATISFIED. DUE TO THE VERY OLD TRAFFIC COUNTS'
 AGE (I.E. 2007) ON WHICH THE LATEST TRAFFIC STUDY IS
 BASED ON, A RECOUNT MAY BE WARRANTED, AS TRAFFIC
 PATTERNS AND VOLUMES MAY HAVE SIGNIFICANTLY CHANGED
 SINCE THEN
 5) NOT SATISFIED. INCLUDE MAINTENANCE BUILDING IN THE
 TRIP GENERATION CALCULATION
 6) NOT SATISFIED. PROVIDE EXISTING CONDITIONS SITE PLAN
 7) NOT SATISFIED. PROVIDE DETAILS OF THE FUTURE PHASE
 OF DEVELOPMENT/EXPANSION BUILDING(S) AND INCLUDE IN THE
 TRIP GENERATION CALCULATION
 8) SATISFIED. PROVIDE SIDEWALK AND WALKWAYS' DIMENSIONS
 IN THE SITE PLAN
 9) PARTIALLY SATISFIED. PROVIDE AUTOTURN ANALYSIS FOR
 GARBAGE TRUCK AND/OR SERVICE VEHICLES DRIVING IN AND
 OUT OF THE PROPOSED DEVELOPMENT WITH VEHICLE DYNAMIC
 ENVELOPES CLEARLY DEFINED. ANALYSIS SHOULD BE PROVIDED
 IN A SEPARATE FILE/DRAWING. PLEASE PROVIDE DOCUMENT
 NAME AND SHEET NUMBER SHOWCASING THE ANALYSIS. LATEST
 SUBMISSION ONLY PROVIDES VEHICLES' PATHS ENTERING AND
 OPERATING WITHIN THE FACILITY, PLEASE PROVIDE VEHICLES'
 EXITING PATHS AS WELL.
 10) SATISFIED. PROVIDE PARKING TABLE SHOWCASING THE
 NUMBER OF REQUIRED AND PROVIDED PARKING SPACES,
 INCLUSIVE OF ADA AND BICYCLE ONES
  
 VALERIO ORICCHIO
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]
  
  Print


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved