| Date |
Text |
| 2021-12-03 16:11:41 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER |
| | 561-822-1462 |
| | PROJECT: ANIMAL RESCUE LEAGUE CSPD Z21110019 |
| | DECEMBER 3, 2021 |
| | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND |
| | PROVIDE THE FOLLOWING COMMENTS: |
| | |
| | 1. MAKE THE FOLLOWING CORRECTIONS TO THE TREE |
| | DISPOSITION PLAN AND LIST: |
| | ? PROVIDE THE CANOPY DIAMETER FOR ALL TREES PROPOSED TO |
| | BE REMOVED AND PROVIDE THE ACTUAL SQUARE FOOTAGE |
| | MITIGATION DUE FOR ANY THAT ARE 20 FEET OR MORE |
| | DIAMETER. |
| | ? RECORD THE MITIGATION SQUARE FOOTAGE DUE BASED ON |
| | CATEGORY FOR ALL TREES LESS THAN 20 FEET CANOPY |
| | DIAMETER AND PALMS THAT ARE PROPOSED FOR REMOVAL. |
| | ? PROVIDE A TOTAL FOR THE MITIGATION SQUARE FOOTAGE |
| | DUE. |
| | ? PROVIDE AN ARBORIST REPORT ON CONDITION AND |
| | RELOCATION POTENTIAL FOR ALL SLASH PINE TREES PROPOSED |
| | TO BE REMOVED. |
| | ? PROVIDE THE MITIGATION CREDITS FOR NEW TREES ADDED TO |
| | SHOW ALL MITIGATION DUE IS COVERED ON SHEET LP-3. |
| | CORRECT OR REMOVE INFORMATION FROM SHEET LP-1. |
| | |
| | 2. PER SECTION 94-443(B) PROVIDE THE 5 FOOT LANDSCAPE |
| | BUFFER ALONG THE SOUTH, EAST AND NORTH PROPERTY LINES |
| | FOR THE NEW AREA ADDED TO THE PD. PROVIDE THE AFFECTED |
| | AREA AND INCLUDE ALL CALCULATIONS AND PLANT LIST ON THE |
| | LANDSCAPE PLANS. |
| | |
| | 3. PER SECTION 94-443 (E)2., PROVIDE THE 30% (NOT 40%) |
| | FOUNDATION PLANTING CALCULATION REQUIRED AND PROVIDED |
| | FOR THE NEW BUILDINGS. |
| | |
| | 4. REMOVE PREFERRED PLANT LABELS FROM THE COLUMNS ON |
| | THE PLANT SCHEDULE. SHOULD BE NATIVE OR DROUGHT |
| | TOLERANT COLUMNS. |
| | |
| | 5. ADD RELOCATED SABAL PALMS TO THE PLANT LIST. |
| | |
| | 6. PROVIDE A SECTION IN A LANDSCAPE DATA CHART TO |
| | COMPLY WITH SECTION 94-445 L. PLANT SPECIES. A MINIMUM |
| | OF 60 PERCENT OF PLANT MATERIAL ADDED SHALL BE FLORIDA |
| | NATIVE OR DROUGHT TOLERANT SPECIES SELECTED FROM THE |
| | CITY LIST OR THE LIST OF SPECIES IN THE MOST RECENT |
| | EDITION OF SOUTH FLORIDA WATER MANAGEMENT DISTRICT |
| | WATERWISE SOUTH FLORIDA LANDSCAPES. PROVIDE THE TOTAL |
| | PERCENTAGE OF NATIVE AND DROUGHT TOLERANT PLANTS BASED |
| | ON FINAL PLANT LIST. |
| | |
| | 7. THE LOCATIONS OF UTILITY LINES FOR THE NEW RESTROOM |
| | INCLUDING ELECTRIC, WATER AND SEWER CONFLICT WITH |
| | EXISTING TREES. ROUTE THE LINES TO AVOID DAMAGE OF ROOT |
| | SYSTEMS. |
| | |
| | 8. ON THE WEST SIDE OF THE PROPOSED MAINTENANCE |
| | BUILDING, SIDEWALK ACCESS FROM THE ADA SPACE SHOULD BE |
| | MOVED EAST TO ALLOW THE TERMINAL LANDSCAPE AREA |
| | ADJACENT TO THE SPACE TO RUN THE FULL LENGTH OF THE |
| | SPACE. |
| | |
| | 9. EXISTING TREES ALONG THE BUFFER NORTH OF THE |
| | PROPOSED MAINTENANCE BUILDING APPEAR TO HAVE PAVEMENT |
| | PROPOSED IN CONFLICT WITH THEIR LOCATIONS. REVISE SITE |
| | PLAN AND LANDSCAPE PLAN. |
| | |
| | CONDITIONS OF APPROVAL |
| | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON |
| | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE |
| | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT |
| | SERVICES DEPARTMENT, PLANNING DIVISION. |
| | |
| |
Print |