Plan Review Notes
Plan Review Notes For Project Z21100021
Project Number Z21100021
Review Stop L
Sequence Number 2
Notes
Date Text
2022-02-23 16:41:30FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER
 561-822-1462
 PROJECT: 1001 OKEECHOBEE Z21100021
 FEBRUARY 23, 2022
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
  
 1. NOT SATISFIED. SECTION 94-448 (D)(3) REQUIRES NATIVE
 TREES AND PALMS IN GOOD CONDITION TO BE PRESERVED ON
 SITE OR RELOCATED. ANSI A 300 (PART 5) STANDARDS
 SPECIFY EXAMPLES OF SUITABILITY RATINGS OF GOOD,
 MODERATE, OR POOR FOR RELOCATION. PROVIDE AN ARBORISTS
 REPORT RATING THE CONDITION AND RELOCATION POTENTIAL
 FOR THE NATIVE TREES AND PALMS. THERE ARE LIVE OAKS,
 SABAL PALMS, FLORIDA THATCH PALMS, AND ROYAL PALMS THAT
 ARE INDICATED TO BE REMOVED. NON NATIVE TREES AND PALMS
 ARE NOT REQUIRED TO BE RELOCATED.
 DOCUMENTATION MUST BE SUBMITTED PRIOR TO SITE PLAN
 APPROVAL TO VERIFY CODE COMPLIANCE.
 2. MAKE THE FOLLOWING CORRECTIONS TO THE TREE
 DISPOSITION LIST:
 ? SATISFIED. ONLY TREES PROPOSED TO BE REMOVED WITH A
 CANOPY DIAMETER OF 20 FEET OR MORE SHOULD HAVE THE
 MITIGATION SQUARE FOOTAGE CALCULATED BASED ON THE
 ACTUAL DIAMETER. TREES LESS THAN 20 FEET CANOPY
 DIAMETER AND PALMS SHOULD SHOW THE CATEGORY MITIGATION
 DUE.
 ? SATISFIED. MULTIPLE PALMS PLANTED TOGETHER MUST HAVE
 EACH SINGLE TRUNK COUNTED TOWARD MITIGATION. TRIPLE
 ADONIDIA WOULD BE 3 X 50 SQ FT.
  
 3. PARTIALLY SATISFIED. PROVIDE A DIAGRAM OF THE
 REQUIRED AND PROVIDED PUBLIC AND PRIVATE OPEN SPACE
 AREAS FOR CLD 25 ZONING DISTRICT. IDENTIFY THE TYPE OF
 OPEN SPACE AS ALLOWED BY TABLE IV-7 AND DEFINITIONS IN
 SECTION 94-109. SHOW HOW THE STANDARDS FOR THE TYPES OF
 OPEN SPACE ARE MET FOR VEGETATED AREAS AND TREE CANOPY
 SQUARE FOOTAGE BASED ON TABLE IV-8 ON THE LANDSCAPE
 PLAN. DIAGRAM ON SHEET A0.07 DOES NOT IDENTIFY THE OPEN
 SPACE TYPE OR CALL OUT HOW THE REQUIREMENTS OF THAT
 TYPE ARE MET.
 THE REQUIRED OPEN SPACE NEEDS TO BE QUANTIFIED,
 IDENTIFIED AS TO THE TYPE, AND ALL REQUIREMENTS NEED TO
 BE SHOWN FOR THAT OPEN SPACE TYPE. FOR OPEN SPACE SHOW
 THE TREE CANOPY SQUARE FOOTAGE FOR TREE TYPES BASED ON
 TABLE IV-8.
 GARDEN PLAZA HAS BEEN IDENTIFIED AS THE PUBLIC OPEN
 SPACE TYPE PROVIDED.
 50% OF THE SPACE IS REQUIRED TO BE VEGETATED AND 50% OF
 THE SQUARE FOOTAGE IN TREE CANOPY STANDARDS MUST BE
 DEMONSTRATED.
 SEMI PUBLIC OPEN SPACE AND PRIVATE OPEN SPACE HAS BEEN
 INDICATED, BUT THE SPECIFIC TYPES HAVE NOT BEEN
 IDENTIFIED SO REQUIREMENTS CANNOT BE VERIFIED.
 ALL REQUIREMENTS MUST BE MET FOR OPEN SPACE BEING OPEN
 TO THE SKY, NO COVERED AREAS MAY BE COUNTED AS OPEN
 SPACE UNLESS THERE IS AN OVERHEAD COVER
  
 4. NOT SATISFIED. IDENTIFY RELOCATED TREES OR PALMS ON
 THE PLANT LIST AND COUNT THEM TOWARD THE REQUIRED
 TREES.
 RELOCATIONS ARE NOT SHOWN AND CANNOT BE DETERMINED
 UNTIL ARBORIST?S REPORT IS RECEIVED.
  
 5. NOT SATISFIED. ALL EXISTING LANDSCAPING MUST BE
 SHOWN ON THE LANDSCAPE PLAN TO PROVIDE A COMPLETE PLAN
 SHOWING COMPLIANCE WITH CURRENT CODE REQUIREMENTS.
 ALL LANDSCAPING FOR THE SITE MUST BE SHOWN ON THE
 LANDSCAPE PLAN.
  
 6. SATISFIED. ARTIFICIAL TURF AREAS PROPOSED MUST MEET
 THE REQUIREMENTS OF SECTION 94-451, INCLUDING ALL AREAS
 THAT ARE ALLOWED BY CODE MUST NOT BE VISIBLE FROM A
 ROAD OR STREET.
 REMOVED FROM PLANS.
  
 7. SATISFIED. BUFFER TREES AND HEDGES MUST BE PROVIDED
 ALONG ALL BUFFERS. THERE IS A LARGE GAP ADJACENT TO THE
 WEST PARKING GARAGE.
  
 8. NOT SATISFIED. PROVIDE CALCULATIONS FOR REQUIRED
 STREET TREES AT MAXIMUM SPACING EVERY 30 FEET OR
 PORTION THEREOF FOR THE OKEECHOBEE STREETSCAPE LENGTH,
 AND SHOW THE NUMBER PROVIDED PER SECTION 94-113 AND
 94-116.
 STREETSCAPE REQUIREMENTS MUST BE MET.
  
 9. PARTIALLY SATISFIED. SHOW ALL EXISTING AND PROPOSED
 WATER AND SEWER AND DRAINAGE LINES ON THE LANDSCAPE
 PLAN. SHOW LOCATIONS OF BACKFLOWS AND ADJUST LOCATIONS
 OF UTILITY LINES TO RESOLVE CONFLICTS WITH EXISTING AND
 PROPOSED TREES AND LANDSCAPING.
 ONCE LOCATIONS ARE FINALIZED, MUST BE SHOWN ON
 LANDSCAPE PLAN.
  
 10. NOT SATISFIED. PLANT LIST NEEDS TO BE MODIFIED TO
 SEPARATE THE REQUIRED OPEN SPACE PLANT LISTS.
 PROVIDE A SEPARATE PLANT LIST FOR EACH OPEN SPACE AREA.
  
  
 11. SATISFIED. NATAL PLUM IS NOT A FLORIDA NATIVE
 PLANT.
  
 12. SATISFIED. SEAGRAPE IS SHOWN ON SHEET L-450, BUT NO
 SEAGRAPE IS PROPOSED ON PLANT LIST.
  
 13. PARTIALLY SATISFIED. PROVIDE THE 50 REQUIRED
 FLORIDA FRIENDLY POINTS BASED ON THE FINAL PLANT LIST
 PER SECTION 94-443(G).
 ADD A COLUMN FOR DROUGHT TOLERANCE TO THE PLANT LIST SO
 THAT IT CAN BE VERIFIED FOR EACH SPECIES.
  
 14. PARTIALLY SATISFIED. SHOW COMPLIANCE WITH SECTION
 94-445 L. PLANT SPECIES. A MINIMUM OF 60 PERCENT OF
 PLANT MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT
 TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE
 LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH
 FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH
 FLORIDA LANDSCAPES. PROVIDE THE ACTUAL PERCENTAGE BASED
 ON THE PLANT LIST.
  
 ADD A COLUMN FOR DROUGHT TOLERANCE TO THE PLANT LIST SO
 THAT IT CAN BE VERIFIED FOR EACH SPECIES. CALCULATIONS
 ARE TO BE BASED ON THE ENTIRE PLANT LIST, NOT JUST
 TREES.
  
  
 15. NOT SATISFIED. ALL SURFACE PARKING MUST MEET THE
 REQUIREMENTS OF SECTION 94-443(C)(3) A. INCLUDING
 TERMINAL LANDSCAPE ISLANDS, INTERIOR ISLANDS AND SHADE
 TREES.
 ALL LANDSCAPE AREAS MUST BE SHOWN ON THE LANDSCAPE
 PLAN.
 TERMINAL LANDSCAPE ISLANDS MUST BE CREATED AT THE ENDS
 OF EACH ROW OF PARKING. INTERIOR ISLANDS MUST BE
 PROVIDED SO THERE ARE NO MORE THAN 10 SPACES IN A ROW.
 EACH LANDSCAPE ISLAND REQUIRES A TREE, AND AT LEAST 75%
 MUST BE CATEGORY 1 SHADE TREES.
 16. NOT SATISFIED. PROVIDE AN EXHIBIT SHOWING THE
 PARKING AREA SURFACE CALCULATIONS, PARKING SPACE AREAS
 AND LANDSCAPE AREAS PROVIDED TO DEMONSTRATE COMPLIANCE
 WITH SECTIONS 94-443 (C)(3) AND (4). PROVIDE THE
 CALCULATIONS IN THE LANDSCAPE REQUIREMENT CHART. REFER
 TO FIGURE XIV-1.
 PARTIAL CALCULATIONS WERE SHOWN, BUT NOT COMPLETE AND
 EXHIBIT WAS NOT PROVIDED.
  
 17. SATISFIED. PROVIDE SCREENING HEDGES FOR ALL GROUND
 MOUNTED VALVES AND EQUIPMENT AND ADD A NOTE THAT ALL
 EQUIPMENT WILL BE SCREENED.
 ADDITIONAL COMMENTS 2/23/22:
 18. THE EAST LANDSCAPE BUFFER IS NOT ON THE PROPERTY,
 IT IS OUTSIDE THE SITE ON A CITY OWNED PARCEL. THIS
 MUST BE ADDRESSED AS TO HOW THE AREA IS TO BE APPROVED
 AND MAINTAINED.
  
 19. REQUIRED OPEN SPACE PER SECTION 94-113 IS DIFFERENT
 AND SEPARATE FROM THE OVERALL LANDSCAPE REQUIREMENTS
 FOR THE SITE. OPEN SPACE AND LANDSCAPE AREAS ON THE
 LANDSCAPE LEGEND SHEET L-401 NEEDS TO BE CORRECTED TO
 REFLECT THIS.
  
 20. C. WEST BUFFER REQUIRES 26 TREES. SOUTH BUFFER
 SHOULD BE 13 TREES REQUIRED.
  
 21. STREET TREES SHOULD BE 13 REQUIRED.
  
 22. FOUNDATION LANDSCAPE REQUIREMENT NEEDS TO SHOW
 TOTAL LINEAR FOOTAGE FOR EACH BUILDING AND SHOW THAT AT
 LEAST 30% OF THAT IS LANDSCAPED AREA.
  
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  
  Print


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved