| Date |
Text |
| 2021-11-18 12:36:08 | 1. PLEASE CONFIRM THE PROPERTY LINE INDICATED IN |
| | DRAWINGS ACCURATELY REFLECT THE LOCATION OF THE |
| | PROPERTY LINE ACCORDING TO SURVEY. |
| | 2. PLEASE PROVIDE A GBA TABLE WITH THE INFORMATION OF |
| | EXISTING ALLOWABLE GBA FOR SITE, EXISTING GBA FOR |
| | MARRIOTT, AND PROPOSED GBA. |
| | 3. PLEASE PROVIDE A FLOOR BY FLOOR PLAN AND TABLE |
| | INDICATING THE AREAS THAT ARE INCLUDED IN THE GBA |
| | CALCULATION ACCORDING TO THE GBA DEFINITION IN SECTION |
| | 94-109. CALL OUT THE USE IN EACH OF THE AREAS. GBA IN |
| | SHEETS A0.14, A0.15 AND A0.16 DO NOT MATCH THE GBA |
| | DEFINITION BY CODE. |
| | 4. PUBLIC OPEN SPACE DOES NOT COMPLY WITH THE |
| | REQUIREMENTS ACCORDING TO SECTION 94-109 OR TABLE IV-7. |
| | PROPOSED PUBLIC OPEN SPACE DOES NOT ABUT AN ACTIVE USE |
| | OR COMPLIES WITH MINIMUM PROPORTIONS. |
| | 5. PROJECT DOES NOT COMPLY WITH THE PRIVATE OPEN SPACE |
| | MINIMUM REQUIREMENTS. PLEASE EXPLAIN THE HARDSHIPS |
| | JUSTIFYING THE VARIANCE REQUEST. |
| | 6. PLEASE PROVIDE COLORED ELEVATIONS WITH CALL OUT |
| | MATERIALS FOR ALL ELEVATIONS. PLEASE INCLUDE PHOTOS OF |
| | PROPOSED MATERIALS. |
| | 7. PLEASE STUDY THE EFFICIENCY OF THE GARAGE LAYOUT FOR |
| | POSSIBLE REDUCTION ON TOTAL NUMBER OF FLOORS. NORTHERN |
| | GARAGE LAYOUT DOES NOT SEEM TO FUNCTION. |
| | 8. PLEASE PROVIDE INFORMATION TO CONFIRM THE PROJECT |
| | COMPLIES WITH THE MAXIMUM 350 FEET FOOTPRINT LENGTH |
| | ALLOWED IN THE DISTRICT. |
| | 9. PROJECT EXCEEDS THE MAXIMUM SETBACK ALLOWED ALONG |
| | OKEECHOBEE BLVD, CREATING A SUBURBAN CONFIGURATION DUE |
| | TO THE LOCATION OF THE VEHICULAR ACCESS DRIVES IN FRONT |
| | OF THE BUILDING. |
| | 10. PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE |
| | WITH MAXIMUM BUILDING FOOTPRINTS ALLOWED. |
| | 11. ON FA?ADE, PLEASE INDICATE THE ELEVATION OF EACH |
| | FLOOR LEVEL. |
| | 12. PROPOSED PROJECT REMOVED THE TURN AROUND SPACE AT |
| | THE END OF CLEARWATER PARK ROAD. IF A GATE AT THE |
| | ENTRANCE OF THE PROPERTY IS INSTALLED, VEHICLES DO NOT |
| | HAVE SPACE TO TURN AROUND. |
| | 13. PLEASE PROVIDE INFORMATION TO CONFIRM THE PROJECT |
| | COMPLIES WITH THE MINIMUM ACTIVE USE REQUIRED ALONG THE |
| | AVENUE DESIGNATION AND THE CSX FRONTAGE. |
| | 14. STREETSCAPE ALONG OKEECHOBEE SHALL BE DESIGNED TO |
| | CONTINUE THE RECENT DESIGN IMPLEMENTED BETWEEN TAMARIND |
| | AND ROSEMARY. STREET TREES PLANTED EVERY 30 FEET, A |
| | CONTINUOUS HEDGE OR GROUND COVER ALONG OKEECHOBEE AND A |
| | MULTIPURPOSE PATH OF 12 FEET IN WIDTH. |
| | 15. PLEASE PROVIDE BUILDING SECTION. |
| | 16. PLEASE PROVIDE GRAPHIC INFORMATION TO CONFIRM |
| | COMPLIANCE WITH THE PLANAR BREAK REQUIREMENTS. |
| | 17. PLEASE NOTE THAT MINIMUM SETBACKS ARE ALSO |
| | APPLICABLE TO GARAGE STRUCTURES. CHECK INFORMATION |
| | PROVIDED IN SHEET A0.01 REGARDING INTERIOR SETBACK. |
| | 18. PLEASE INDICATE THE LOCATION OF THE REQUIRED PUBLIC |
| | BIKE PARKING SPACES 1/100? FEET OF FRONTAGE. |
| | 19. PLEASE INDICATE THE LOCATION OF THE REQUIRED |
| | SECURED BIKE PARKING FOR THE OFFICE USE AT A RATIO OF |
| | 1/15 PARKING SPACES PROVIDED (74 BIKE SPACES REQUIRED). |
| | 20. FOR THE PARKING CALCULATIONS, PLEASE LIST EACH OF |
| | THE EXISTING AND PROPOSED USES (WITH NET SQUARE FOOTAGE |
| | OR NUMBER OF ROOMS) AND THE REQUIRED AND PROVIDED |
| | PARKING. |
| | 21. PLEASE IDENTIFY THE ROUTE OF PEDESTRIAN ACCESS TO |
| | THE HOTEL AND OFFICE FROM CLEARWATER PARK ROAD. |
| | 22. PLEASE PROVIDE NARRATIVE JSUTIFYING THE REQUESTED |
| | VARIANCES. DETAILED COMPLIANCE WITH VARIANCE STANDARDS |
| | WILL BE REQUIRED FOR DAC REVIEW. |
| | FOR RESUBMITTAL, PLEASE PROVIDE A RESPONSE SHEET |
| | ADDRESSING ALL COMMENTS. PLEASE INDICATE WHERE IN THE |
| | DRAWINGS THE UPDATED INFORMATION CAN BE FOUND IF |
| | POSSIBLE. SUBMIT ONE LARGE PRINTED SET AND ONE CD WITH |
| | THE ELECTRONIC COPY OF THE DRAWING AND ALL SUPPORT |
| | INFORMATION (INCLUDING RESPONSE LETTER). |
| | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA |
| | APONTE AT 561-822-1439. |
| | |
| |
Print |